Atria 6100 Operator's manual - Roxon
Atria 6100 Operator's manual - Roxon Atria 6100 Operator's manual - Roxon
7 Acquiring ECG ReportsPlain Paper PrintingThe Atria can be configured to print ECGs to a plain paper printer.!CautionData loss. Always check plain paper printouts before disconnecting thepatient and ending the procedure.Printing Problems (Thermal Printer)If the Atria runs out of paper or if the paper jams while printing an ECG,either reload the paper and continue printing, or press [Stop] to save therecord without printing.For paper loading instructions see “Loading Recording Paper” on pg. 2-5 orpress [ALT] + [H] to access the Help menu and then select Loading Paper.Saving ReportsThe Atria automatically saves ECGs. If the Atria is set up for networkaccess, the ECG can also be automatically sent or emailed. For moreinformation, see “Sequence” on pg. 4-5.NOTE: To disable automatic saving of ECG reports, see“Auto Save” on pg. 4-5.After the ECG has been saved, the Patient Review menu is displayed. See“How to Display a Patient Record” on pg. 8-2.ECG TipsPatient Data and Interpretation• Enter all patient information. Some patient informationdirectly affects ECG analysis. The physician uses thisinformation when interpreting ECG reports. Also, aninterpretive Atria provides more accurate and completeanalysis statements when patient information is complete.• Enter patient information at any time (either before or afterthe ECG). Changing age, gender, race, medication or clinicalclassification after acquisition, causes the interpretive Atriato prompt to reanalyze the data. Any changes ininterpretation are included in future printouts. If the data isnot reanalyzed, edits are not saved.7-4 Atria Electrocardiograph Operating Instructions
Change Recorder Speed, Gain, Frequency ResponseAcquiring a Clean Trace• To obtain a clean trace with very little noise, ensure Wait forGood Data is set to ON in the ECG menu. If there is a problemduring a recording, the Atria displays a message. Ifnecessary, override the error message and continuerecording by pressing the [ECG] key again (for moreinformation, see “Wait for good data” on pg. 4-5).NOTE: If Wait for Good Data is set to ON in the ECG menu,then it is possible to press [ECG] prior to connecting thepatient. The Atria waits until all leads are connected and theacquired ECG traces settle (the Atria detects good data)before automatically starting the ECG.Change Recorder Speed, Gain, Frequency ResponseTo temporarily change print settings for the current patient use thefollowing shortcuts:Key Description Selections[7] Select paper speed 12.5 mm/s25 mm/s50 mm/s[8] Selects the ECG gain 5mm/mV10 mm/mV20 mm/mVL10,C5 mm/mVL20, C10 mm/mV[9] Toggles the upper ECG filter frequency response 40 Hz150 HzNOTE: The updated settings remain in effect untilchanged again or the Atria is restarted.Atria Electrocardiograph Operating Instructions 7-5
- Page 24 and 25: 3 User InterfaceFunction Key Descri
- Page 28 and 29: 3 User InterfaceLabel Text Descript
- Page 30 and 31: 3 User InterfaceDisplay Atria 3100T
- Page 32 and 33: 3 User Interface3-12 Atria Electroc
- Page 34 and 35: 4 User SettingsSetup MenuThe Setup
- Page 36: 4 User SettingsECGMenu Items:Report
- Page 39 and 40: Waveform PreferencesWaveform Prefer
- Page 41 and 42: RhythmRhythmTo print rhythm reports
- Page 43 and 44: Patient SettingsRhythmMenu Items:Se
- Page 45 and 46: System SettingsSystem SettingsUse t
- Page 47 and 48: Chapter5 Communications Setup!WARNI
- Page 49 and 50: GroundingGroundingAll connected equ
- Page 51 and 52: Network Setup3. Enter the following
- Page 53 and 54: Network SetupCREATE A SUPPLICANT CO
- Page 55 and 56: External Printer Setup• Start Fin
- Page 57 and 58: Setup Email2. Select Send Receive >
- Page 59 and 60: Setup EMR Communications7. Enter th
- Page 61 and 62: Chapter6 Patient Preparation!!!WARN
- Page 63 and 64: Sensor ApplicationSensor Applicatio
- Page 65 and 66: Disposable Resting ECG SensorsDispo
- Page 67 and 68: Reusable ECG Sensors3. Squeeze out
- Page 69 and 70: Alternative Lead PlacementsAcquire
- Page 71 and 72: Chapter7 Acquiring ECG ReportsAcqui
- Page 73: Acquiring an ECG Using Pediatric Le
- Page 77 and 78: Patient DemographicsPatient Demogra
- Page 79 and 80: Patient DemographicsWeightSystolic
- Page 81 and 82: Chapter8 Patient RecordsWorking wit
- Page 83 and 84: How to Display a Patient Record•
- Page 85 and 86: How to Display a Patient RecordPrin
- Page 87 and 88: Communications OptionsA Directory F
- Page 89 and 90: Communications OptionsEmail a Patie
- Page 91 and 92: Communications OptionsRETRIEVING EC
- Page 93 and 94: Chapter9 Sample PrintoutsNOTE: The
- Page 95 and 96: Setup ReportSetup ReportThe Setup R
- Page 97 and 98: Standard 12-Lead, 4-Channel ECG, Br
- Page 99 and 100: Standard 3-Channel Rhythm & Manual
- Page 101 and 102: Median Complex, Brief StatementsMed
- Page 103 and 104: Chapter 10 TroubleshootingThis chap
- Page 105 and 106: Trace ProblemsPROBLEMWaveforms are
- Page 107 and 108: Recognizing and Reducing ECG Artifa
- Page 109 and 110: Recognizing and Reducing ECG Artifa
- Page 111 and 112: Chapter 11 Maintenance and ServiceC
- Page 113 and 114: AnnuallyTestingThe Atria performs a
- Page 115 and 116: Component ReplacementFigure 11-1Atr
- Page 117 and 118: Notice to Responsible Service Perso
- Page 119 and 120: Performance Disclosures40 Hz Artifa
- Page 121 and 122: EMC Declaration TablesElectromagnet
- Page 123 and 124: EMC Declaration TablesRecommended S
Change Recorder Speed, Gain, Frequency ResponseAcquiring a Clean Trace• To obtain a clean trace with very little noise, ensure Wait forGood Data is set to ON in the ECG menu. If there is a problemduring a recording, the <strong>Atria</strong> displays a message. Ifnecessary, override the error message and continuerecording by pressing the [ECG] key again (for moreinformation, see “Wait for good data” on pg. 4-5).NOTE: If Wait for Good Data is set to ON in the ECG menu,then it is possible to press [ECG] prior to connecting thepatient. The <strong>Atria</strong> waits until all leads are connected and theacquired ECG traces settle (the <strong>Atria</strong> detects good data)before automatically starting the ECG.Change Recorder Speed, Gain, Frequency ResponseTo temporarily change print settings for the current patient use thefollowing shortcuts:Key Description Selections[7] Select paper speed 12.5 mm/s25 mm/s50 mm/s[8] Selects the ECG gain 5mm/mV10 mm/mV20 mm/mVL10,C5 mm/mVL20, C10 mm/mV[9] Toggles the upper ECG filter frequency response 40 Hz150 HzNOTE: The updated settings remain in effect untilchanged again or the <strong>Atria</strong> is restarted.<strong>Atria</strong> Electrocardiograph Operating Instructions 7-5