6 Patient PreparationReusable ECG Sensors!CautionBaseline drift. Never mix patient electrode types or brands. Dissimilarmetals or other incompatibilities may cause considerable baseline driftand may increase trace recovery time after defibrillation.ElectrolyteNOTE: Watches or jewelry may be damaged by contactwith electrolyte.Cardiac Science Corporation recommends using Signa gel ® electrode gelwith reusable sensors because it provides excellent conductivity betweenthe skin and sensor.Reusable sensors (Welsh bulbs and limb plates) must be kept clean. Dirt orelectrolyte build-up may degrade ECG quality:• Wash after each use (use a mild dish soap if necessary)• Never use a metallic pad to clean plates and Welsh bulbs (toavoid damaging the plating)• Discard if corroded.Applying limb plates!CautionPatient skin irritation. Limb Plates may contain nickel, a material that cancause skin irritation. Monitor the electrode site and, if irritation occurs,use an alternate electrode.1. Expose the arms and legs of the patient.2. Connect sensor straps to the “ears” of the limb plates.6-6 Atria Electrocardiograph Operating Instructions
Reusable ECG Sensors3. Squeeze out a small amount of Signa gel electrode gel on limb plate asillustrated. Spread it evenly over the limb plate surface. Apply thesame amount of electrolyte to each sensor.4. Place sensors firmly on the limb sites. Choose fleshy areas above wristsand ankles. Position so the limb plate will not press against the body ortable when the patient is relaxed. On arms, the screws should pointdownward toward the feet. On legs, the screws should point upward,toward chest.5. Without stretching the strap, wrap it around the limb until a hole linesup with a sensor “ear.” Then stretch the strap and fasten it with thenext hole.6. Connect the limb leads to the four limb plates.Applying Welsh bulb chest sensors!CautionPatient skin irritation. Welsh bulb sensors may contain nickel, a materialthat can cause skin irritation. Monitor the electrode site and, if irritationoccurs, use an alternate electrode.1. Connect the 6 Welsh bulb sensors to the V-leads (C-leads) on thepatient cable.2. Locate the 6 V-lead (C-lead) positions on the patient’s chest (see “RestingECG Lead Placement & Coding Chart” on pg. 6-4).3. Squeeze out a drop of Signa gel electrode gel at each sensor site. Use atongue depressor to spread the electrolyte (ensure it does not touch theelectrolyte from another site).4. Apply the sensors by squeezing the rubber bulb and allowing suction tohold the sensor in place. Only a small dimple should remain on thebulb when it is released.5. Ensure the leads conform to the body contours and no strain is placedon the sensors.6. Wipe off any residual electrolyte and check again to ensure electrolytefrom one site does not touch another site.Atria Electrocardiograph Operating Instructions 6-7
- Page 16 and 17: 2 Equipment Setup!!WARNINGMisdiagno
- Page 18 and 19: 2 Equipment SetupPower IndicatorA g
- Page 20 and 21: 2 Equipment Setup6. Slide the door
- Page 22 and 23: 3 User InterfaceFigure 3-2User Inte
- Page 24 and 25: 3 User InterfaceFunction Key Descri
- Page 28 and 29: 3 User InterfaceLabel Text Descript
- Page 30 and 31: 3 User InterfaceDisplay Atria 3100T
- Page 32 and 33: 3 User Interface3-12 Atria Electroc
- Page 34 and 35: 4 User SettingsSetup MenuThe Setup
- Page 36: 4 User SettingsECGMenu Items:Report
- Page 39 and 40: Waveform PreferencesWaveform Prefer
- Page 41 and 42: RhythmRhythmTo print rhythm reports
- Page 43 and 44: Patient SettingsRhythmMenu Items:Se
- Page 45 and 46: System SettingsSystem SettingsUse t
- Page 47 and 48: Chapter5 Communications Setup!WARNI
- Page 49 and 50: GroundingGroundingAll connected equ
- Page 51 and 52: Network Setup3. Enter the following
- Page 53 and 54: Network SetupCREATE A SUPPLICANT CO
- Page 55 and 56: External Printer Setup• Start Fin
- Page 57 and 58: Setup Email2. Select Send Receive >
- Page 59 and 60: Setup EMR Communications7. Enter th
- Page 61 and 62: Chapter6 Patient Preparation!!!WARN
- Page 63 and 64: Sensor ApplicationSensor Applicatio
- Page 65: Disposable Resting ECG SensorsDispo
- Page 69 and 70: Alternative Lead PlacementsAcquire
- Page 71 and 72: Chapter7 Acquiring ECG ReportsAcqui
- Page 73 and 74: Acquiring an ECG Using Pediatric Le
- Page 75 and 76: Change Recorder Speed, Gain, Freque
- Page 77 and 78: Patient DemographicsPatient Demogra
- Page 79 and 80: Patient DemographicsWeightSystolic
- Page 81 and 82: Chapter8 Patient RecordsWorking wit
- Page 83 and 84: How to Display a Patient Record•
- Page 85 and 86: How to Display a Patient RecordPrin
- Page 87 and 88: Communications OptionsA Directory F
- Page 89 and 90: Communications OptionsEmail a Patie
- Page 91 and 92: Communications OptionsRETRIEVING EC
- Page 93 and 94: Chapter9 Sample PrintoutsNOTE: The
- Page 95 and 96: Setup ReportSetup ReportThe Setup R
- Page 97 and 98: Standard 12-Lead, 4-Channel ECG, Br
- Page 99 and 100: Standard 3-Channel Rhythm & Manual
- Page 101 and 102: Median Complex, Brief StatementsMed
- Page 103 and 104: Chapter 10 TroubleshootingThis chap
- Page 105 and 106: Trace ProblemsPROBLEMWaveforms are
- Page 107 and 108: Recognizing and Reducing ECG Artifa
- Page 109 and 110: Recognizing and Reducing ECG Artifa
- Page 111 and 112: Chapter 11 Maintenance and ServiceC
- Page 113 and 114: AnnuallyTestingThe Atria performs a
- Page 115 and 116: Component ReplacementFigure 11-1Atr
Reusable ECG Sensors3. Squeeze out a small amount of Signa gel electrode gel on limb plate asillustrated. Spread it evenly over the limb plate surface. Apply thesame amount of electrolyte to each sensor.4. Place sensors firmly on the limb sites. Choose fleshy areas above wristsand ankles. Position so the limb plate will not press against the body ortable when the patient is relaxed. On arms, the screws should pointdownward toward the feet. On legs, the screws should point upward,toward chest.5. Without stretching the strap, wrap it around the limb until a hole linesup with a sensor “ear.” Then stretch the strap and fasten it with thenext hole.6. Connect the limb leads to the four limb plates.Applying Welsh bulb chest sensors!CautionPatient skin irritation. Welsh bulb sensors may contain nickel, a materialthat can cause skin irritation. Monitor the electrode site and, if irritationoccurs, use an alternate electrode.1. Connect the 6 Welsh bulb sensors to the V-leads (C-leads) on thepatient cable.2. Locate the 6 V-lead (C-lead) positions on the patient’s chest (see “RestingECG Lead Placement & Coding Chart” on pg. 6-4).3. Squeeze out a drop of Signa gel electrode gel at each sensor site. Use atongue depressor to spread the electrolyte (ensure it does not touch theelectrolyte from another site).4. Apply the sensors by squeezing the rubber bulb and allowing suction tohold the sensor in place. Only a small dimple should remain on thebulb when it is released.5. Ensure the leads conform to the body contours and no strain is placedon the sensors.6. Wipe off any residual electrolyte and check again to ensure electrolytefrom one site does not touch another site.<strong>Atria</strong> Electrocardiograph Operating Instructions 6-7