11 Maintenance and ServiceImmunitytestConducted RFIEC <strong>6100</strong>0-4-6Radiated RFIEC <strong>6100</strong>0-4-3IEC 60601test level3 Vrms150 kHz to 80MHz3 V/m80 MHz to 2,5GHzCompliancelevelElectromagnetic environment -guidancePortable and mobile RF communicationsequipment should be used no closer to anypart of the <strong>Atria</strong>, including cables, than therecommended separation distancecalculated from the equation applicable tothe frequency of the transmitter.Recommended separation distance3 V cd = 1.2 √ P3 V/m c d = 1.2 √ P 80 MHz to 800 MHzd = 2.3 √ P800 MHz to 2,5 GHzwhere P is the maximum output powerrating of the transmitter in watts (W)according to the transmitter manufacturerand d is the recommended separationdistance in metres (m).Field strengths from fixed RF transmitters,as determined by an electromagnetic sitesurvey, a should be less than the compliancelevel in each frequency range. bInterference may occur in the vicinity ofequipment marked with the followingsymbol:NOTE 1: At 80 MHz and 800MHz, the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affectedby absorption and reflection from structures, objects and people.a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcastcannot be predicted theoretically with accuracy. To assess the electromagnetic environment dueto fixed RF transmitters, an electromagnetic site survey should be considered. If the measured fieldstrength in the location in which the <strong>Atria</strong> is used exceeds the applicable RF compliance levelabove, then the <strong>Atria</strong> should be observed to verify normal operation. If abnormal performance isobserved, additional measures may be necessary, such as reorienting or relocating the <strong>Atria</strong>.bOver the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.c Amplitude modulated at 80% with a modulation frequency of 10 KHz per EN 60601-2-25.11-12 <strong>Atria</strong> Electrocardiograph Operating Instructions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!