ecolader: rapid discharger/charger series - Schulze Elektronik GmbH
ecolader: rapid discharger/charger series - Schulze Elektronik GmbH
ecolader: rapid discharger/charger series - Schulze Elektronik GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>ecolader</strong>: <strong>rapid</strong> <strong>dis<strong>charger</strong></strong>/<strong>charger</strong> <strong>series</strong><br />
Operating instructions for software V1.04, date of issue 05 MAY 1998<br />
14.4 Pin-outs of auxiliary sockets, seen from solder side of sockets<br />
Socket polarity<br />
schulze<br />
elektronik<br />
gmbh<br />
Page 33<br />
- - - - - + - + x - S R x Jumper, do not remove (Note: S,R,T = cal. output)<br />
- - - - - + - + - + T - Code connector, one pin absent, blind pin<br />
must be fitted in the socket<br />
(+,- = temp. sensor input)<br />
Disch. load* Flasher Fan Temp.Sensor/cal. Apply solder bridge to socket<br />
14.5* Pin-outs of PC interface, seen from solder side of socket<br />
T Gnd RS-232 interface SUB D socket 9-pin (25-pin)<br />
T = Transmit; connect to RXD Pin 2 (Pin 3)<br />
R = Receive; connect to TXD Pin 3 (Pin 2)<br />
R Gnd Signal GND; connect to GND Pin 5 (Pin 7)<br />
X = Code connector, one pin absent. Blind pin fitted in matching socket on RS-232 cable.<br />
14.6* Pin-outs of 8-channel ADC, seen from solder side of socket<br />
K 2+4+6+ x K = Calibration voltage output, not used when measuring batteries.<br />
1- = Negative terminal of whole battery pack (first cell)<br />
7+ = Positive terminal of whole battery pack (last cell)<br />
1-1+3+5+7+ 1+ ... 7+ = Voltage pick-ups at cell positive terminals. Keep to correct sequence of wires.<br />
X = Code connector, one pin absent. Blind pin in matching socket on sensor cable.<br />
14.7* Data format, PC interface<br />
Transmission speed: 9600 Baud<br />
Data set in ASCII: A:sssss:uuuuu:iiiiiVSttt##<br />
<strong>ecolader</strong> select 2 ;U1;U2;U3;U4;U5;U6;U7;Ug;<br />
Legend: A Battery No.<br />
sssss Time in seconds<br />
uuuuu Battery voltage in Millivolts<br />
iiiii Current in Milliamperes<br />
V[:,-] Current prefix<br />
S[l,L,E,t...] Charge / discharge status<br />
ttt[-, ,0..9] Temperature<br />
U1...7 12-bit cell voltage, 1-7 in mV 2<br />
Ug 12-bit overall voltage, U1...U7 in mV 2<br />
: or ; Data separator<br />
Comment set: *, Date, Day, Time, data source, battery No.,<br />
program in use, current combination program phase,<br />
charge method in use, charge termination criterion,<br />
Cell count 3<br />
[ 2 ] only if Akku 1 is in use alone<br />
[ 3 ] calculated cell count, which may be corrected automatically by the <strong>charger</strong> within the first 10 minutes<br />
of the charge process. Left unchanged if manually corrected.<br />
schulze elektronik gmbh • prenzlauer weg 6 • D-64331 weiterstadt • tel: 06150/1306-5, fax: 1306-99<br />
internet: http://www.schulze-elektronik.com e-mail: mail@schulze-elektronik.com