14.1 Specification<br />

all models Weight Size Screen Screen<br />

approx. [kg] approx. [mm] [line x char] [area]<br />

1.1 207 x 142 x 58 2 x 16 61x15mm<br />

akku 1 akku 2 akku 3<br />

No. of cells (1-71 ) 4 - 7 (1-71 ) 4 - 7 (1-81 ) 4 - 8<br />

Charge / discharge currents 0.3 - 10 A 0.15 - 5 A 0.1 - 2 A<br />

Charge / discharge power max. 60 W 32 W 24 W<br />

for cell capacity<br />

Tolerances, <strong>ecolader</strong> +<br />

0.3 - 5 Ah 0.15 - 2.5 Ah 0.1-1 Ah<br />

Current, Batt. 1 & 2: typ. 5%; max. 15% or 250 mA (whichever is the greater)<br />

Current, Batt. 3: typ. 5%; max. 10% or 100 mA (whichever is the greater)<br />

Voltage: typ. 5%, max .10%<br />

Tolerances, <strong>ecolader</strong> select<br />

Current, Batt. 1 & 2: typ. 3%; max. 5% or 200 mA (whichever is the greater)<br />

Current, Batt. 3: typ. 5%; max. 10% or 100 mA (whichever is the greater)<br />

Voltage: typ. 3%, max. 5%<br />

12-bit ADC: typ. 1%, max. 3%<br />

Miscellaneous information:<br />

[ 1 ] All charge outputs can be used with 1 cell or more provided that the charge current is at least<br />

3 C and temperature monitoring is used for charging. Peak detection is too unreliable in such<br />

cases.<br />

- Total power dissipation of > 60 W can result in system shut-down due to overheating.<br />

- No-load current drain: approx. 200 mA<br />

- Power supply: 11 - 15.2 V<br />

- All data assumes a car battery voltage of 12 V ... 13.8 V DC<br />

- Recommended car battery: 12 V / 36 Ah or larger; must be fully charged to charge 7 cells!<br />

- Recommended mains PSU: 13.8V (required to charge 7 cells), ideally switchable to 12 V (recommended<br />

for charging 6 cells, as the <strong>ecolader</strong> stays cooler; current: 20/22 A.<br />

14.2 Other features<br />

- fully automatic charge current calculation, patent applied for<br />

- All battery outputs can be used simultaneously<br />

- All battery outputs suitable for Ni-Cd and Ni-MH batteries<br />

- Safety charge termination after selectable charge times<br />

- Safety charge termination according to selectable charge quantity<br />

- Safety charge termination according to selectable temperature (selectable battery output)<br />

- Low voltage warning, selectable within the range 10.4 - 11.6 V<br />

- Low voltage shut-down at 0.5 V below warning threshold<br />

- Electronic circuit-breaker in the + 12 V line for external connections<br />

<strong>ecolader</strong> select:<br />

- Precision 8-channel 12-bit analogue-digital converter provides selection facility for individual<br />

battery cells<br />

- Socket for external discharge load resistances (for 6-cell batteries preferably 0.40 Ohm, 300 W)<br />

14.3 Default settings for battery programs and <strong>charger</strong><br />

See Section 8.21; the default values are also underlined in the value ranges stated in the sub-sections<br />

of Section 8.<br />

schulze elektronik gmbh • prenzlauer weg 6 • D-64331 weiterstadt • tel: 06150/1306-5, fax: 1306-99<br />

internet: http://www.schulze-elektronik.com e-mail: mail@schulze-elektronik.com