8.8 Termination temperature<br />

Description:<br />

This function has a dual purpose: it provides<br />

extra safety when the charge is terminated<br />

using the (voltage) peak detection<br />

feature.<br />

It can also be used as an independent<br />

method of "battery full" charge termination.<br />

Activating the menu point:<br />

Press the akku x button.<br />

Select value:<br />

Press the + or - button.<br />

Value range:<br />

23° C ... 45° C ... 50° C.<br />

Fixed temperature values:<br />

41° C, 65° C (see notes below).<br />

Confirm value:<br />

Press enter<br />

Interrupt:<br />

Press esc<br />

Notes:<br />

The temperature limit values can be set<br />

separately for each battery, but the <strong>charger</strong><br />

only has one temperature sensor, which<br />

must be activated on a battery-specific basis<br />

under the menu point Charge Termination<br />

Criterion (see Section 8.12).<br />

In addition a fixed, non battery-specific<br />

temperature value of 65° C is active for the<br />

whole device during every charge and discharge<br />

process as an "emergency power<br />

cut-off" system. Simply push the temperature<br />

sensor into the battery to be monitored.<br />

Moreover there is a non-selectable temperature<br />

limit of 41° C which delays a discharge<br />

process involving a battery above<br />

this temperature until it cools down to below<br />

this value; this only applies if temperature<br />

termination has been selected.<br />

The temperature sensor should be plugged<br />

into the socket marked cal on the <strong>ecolader</strong><br />

+.<br />

8.9 Termination delay<br />

Decription:<br />

This function is useful with cells which really<br />

refuse to be charged by erroneously tripping<br />

the peak detection system. It does this by<br />

charging for the first few minutes without<br />

checking the voltage peak.<br />

Activating the menu point:<br />

Press the akku x button.<br />

Select value:<br />

Press the + or - button.<br />

Value range:<br />

1 min ... 8 min ... 10 min.<br />

Confirm value:<br />

Press enter<br />

Interrupt:<br />

Press esc<br />

Notes:<br />

However, since the automatic charge termination<br />

system is very reliable in operation,<br />

and since a wide variety of termination criteria<br />

are taken into account and analysed, this<br />

function only needs to be activated in very<br />

rare cases.<br />

Entering a delay time does not immediately<br />

result in a delayed activation of the automatic<br />

charge termination system. This has to<br />

include the additional "del." component in<br />

the termination criterion (see Section 8.12).<br />

"One-Batt-Screen" mode<br />

22:17a8.50V 22:17a8.50V 4.7A<br />

4.7A<br />

nA1 A1 A1nL^de08.q0046<br />

A1 L^de08.q0046<br />

schulze elektronik gmbh • prenzlauer weg 6 • D-64331 weiterstadt • tel: 06150/1306-5, fax: 1306-99<br />

internet: http://www.schulze-elektronik.com e-mail: mail@schulze-elektronik.com<br />

Ch. time<br />

Batt1 code:<br />

"Onebattfullscreen"<br />

"full" probability<br />

Battery<br />

voltage<br />

Linear ch.<br />

Peak termination<br />

delayed by 8 minutes<br />

"Two-Batt-Screen" mode<br />

Line 1 = Battery 1<br />

Line 2 = Battery 2<br />

Pulsed ch.<br />

Temperaturetermination<br />

Pl. holder for<br />

7 00 start time<br />

symbol<br />

A1P°ready A1P°ready I=6.0A<br />

I=6.0A<br />

08:55 08:55 9.19V#3.0A<br />

9.19V#3.0A<br />

Ch. time Battery<br />

voltage<br />

Ch. current<br />

Ch. quantity<br />

in mAh, after<br />

10 Ah in Ah.<br />

q stands for<br />

"Quantity"<br />

Fixed current<br />

charge program<br />

Charge current<br />

"Reduced" symbol, since<br />

primary current set to 9 A<br />

Indirect displays: Batt. 2 set to peak term., as battery 1 is set to temp. termination.<br />

Batt. 2 is on pulsed charge, as battery 1 is set to pulsed charge.