ecolader: rapid discharger/charger series - Schulze Elektronik GmbH
ecolader: rapid discharger/charger series - Schulze Elektronik GmbH
ecolader: rapid discharger/charger series - Schulze Elektronik GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>ecolader</strong>: <strong>rapid</strong> <strong>dis<strong>charger</strong></strong>/<strong>charger</strong> <strong>series</strong><br />
Operating instructions for software V1.04, date of issue 05 MAY 1998<br />
8.6 Maximum charge time<br />
Description:<br />
This is a safety function.<br />
If for any reason the charge termination criterion<br />
you have selected should fail, the<br />
charge current is switched off after the set<br />
maximum charge time has elapsed.<br />
Activating the menu point:<br />
Press the akku x button.<br />
Select value :<br />
Press the + or - button.<br />
Value range:<br />
5 min ... 50 min ... >11 h (i.e. > 660 min).<br />
Confirm value:<br />
Press enter<br />
Interrupt:<br />
Press esc<br />
Special feature:<br />
You will see a > symbol in front of the largest<br />
number in the table. This means that the<br />
charge time monitor is switched off!<br />
Notes:<br />
The charge time limiter and the option of<br />
switching off the charge time limit described<br />
in this Section do not disable the automatic<br />
charge termination circuits.<br />
If you wish to disable the automatic charge<br />
termination system, please use the continuous<br />
charge program (see Section 8.12).<br />
It is particularly important to set charge time<br />
limiting and charge quantity limiting to values<br />
appropriate to the battery when you are<br />
charging transmitter batteries.<br />
If this safety function trips, it ends any combination<br />
program (...CD or ...DC) which may<br />
be in use at that time.<br />
8.7 Max. charge quantity<br />
schulze<br />
elektronik<br />
gmbh<br />
Page 13<br />
Description:<br />
This is a safety function.<br />
If for any reason the charge termination criterion<br />
you have selected should fail, the<br />
charge current is switched off after the set<br />
maximum charge quantity has been supplied.<br />
Activating the menu point:<br />
Press the akku x button.<br />
Select value:<br />
Press the + or - button<br />
Value range:<br />
100 mAh ... 3000 mAh ... >11 Ah<br />
Confirm value:<br />
Press enter<br />
Interrupt:<br />
Press esc<br />
Special feature:<br />
You will see a > symbol in front of the largest<br />
number in the table. This means that the<br />
max. charge quantity monitor is switched<br />
off!<br />
Notes:<br />
It is particularly important to set charge time<br />
limiting and charge quantity limiting to values<br />
appropriate to the battery when you are<br />
charging transmitter batteries.<br />
The default value (3000 mAh) is correct for<br />
selected 2000 mAh packs which have been<br />
discharged down to 0 V. For normal 1700<br />
cells which have only been discharged down<br />
to 0.7 V per cell, a limit value of 2400 - 2600<br />
mAh is a safer option.<br />
If this safety function trips, it ends any combination<br />
program (...CD or ...DC) which may<br />
be in use at that time.<br />
schulze elektronik gmbh • prenzlauer weg 6 • D-64331 weiterstadt • tel: 06150/1306-5, fax: 1306-99<br />