10.07.2015 Views

New Researches in Biotechnology - Facultatea de Biotehnologii ...

New Researches in Biotechnology - Facultatea de Biotehnologii ...

New Researches in Biotechnology - Facultatea de Biotehnologii ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Proceed<strong>in</strong>g of the 4 rd International Symposium“NEW RESEARCH IN BIOTECHNOLOGY” USAMV Bucharest, Romania, 2011Sample handl<strong>in</strong>g - In this study 24 w<strong>in</strong>e samples (10 white and 14 red) fromMuntenia and Oltenia region were analyzed. The analyzed red w<strong>in</strong>e varieties were FeteascaNeagra, Cabernet Sauvignon, Merlot, P<strong>in</strong>ot Noire and those of white w<strong>in</strong>es varieties wereFeteasca Regala, Tamaioasa Romaneasca, Sauvignon Blanc, Feteasca Alba, Riesl<strong>in</strong>g Italianand Muscat Ottonel. All samples were filtered through 0.45 µm filters prior to analysis andkept protected from light at 4 °CHPLC analysisThe chromatographic analysis was carried out with a Thermo F<strong>in</strong>nigan SurveyorPlus chromatograph equipped with a photodio<strong>de</strong> array <strong>de</strong>tector at 310 nm, Surveyorautosampler, Surveyor LC Pump (Quaternary gradient). Data analysis was done us<strong>in</strong>g theChrome Quest Chromatography Workstation.The analytical column aquasil C18, 250×4.6mm with the sorbent particle size of 5 µm. The mobile phase mixed ofwater:acetonitrile:acetic acid = 70:29.9:0.1 has flown through the system at a rate of 1ml/m<strong>in</strong>. Samples of 20 µl volume were <strong>in</strong>jected <strong>in</strong>to the analytical column. All analyseswere carried out at ambient temperature. Quantification was based on the peak area, us<strong>in</strong>gthe external standard method.3. RESULTS AND DISCUSSIONSValidation studiesCalibration curve was performed by analysis <strong>in</strong> duplicate of eight standards oftrans-resveratrol cover<strong>in</strong>g the range 0.25-10 mg/L. The constructed calibration curveshoved excellent l<strong>in</strong>earity (correlation coefficient: 0.9991) (fig. 2).500000040000003000000Area2000000100000017800 1 2 3 4 5 6 7 8 9 10 11concentration (mg/L)Figure 2. Calibration curve for trans-resveratrolThe l<strong>in</strong>earity of the <strong>de</strong>tector response for the prepared standards was assessed bymeans of a l<strong>in</strong>ear regression analysis regard<strong>in</strong>g the amounts of each standard <strong>in</strong>troduced <strong>in</strong>the loop of the chromatographic system and the area of the correspond<strong>in</strong>g peak on thechromatogram.Detection and quantification limits were calculated by measur<strong>in</strong>g the response ofanalytical background by runn<strong>in</strong>g six blanks (12% alcoholic solution), us<strong>in</strong>g the maximumsensitivity allowed by the system and calculat<strong>in</strong>g the standard <strong>de</strong>viation of this response

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!