10.07.2015 Views

Cold Power Liquid - Colgate

Cold Power Liquid - Colgate

Cold Power Liquid - Colgate

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Material Safety Data SheetCS: 1.6.25Page: 2of5Infosafe No LQ1TP Issue Date : November 2012 ISSUED by COLGATEProduct Name :COLD POWER ULTRA HDL DETERGENT - REGULAR - FRONT LOADERAdvice to DoctorOther Information5. FIRE FIGHTING MEASURESSuitableExtinguishing MediaHazards fromCombustionProductsSpecific HazardsPrecautions inconnection with FireTreat symptomatically.For advice in an emergency, contact a Poisons Information Centre (PhoneAustralia 13 1126; New Zealand 0800 POISON / 0800 764 766) or a doctor atonce.Use extinguishing media suitable for surrounding environment.Under fire conditions this product may emit toxic and/or irritating fumes andgases including carbon monoxide, carbon dioxide, oxides of sulphur, oxides ofphosphorus and oxides of nitrogen.Non-flammable. However under fire conditions, once the aqueous component hasbeen driven off the dried residue may burn. Fire-exposed containers mayrupture/explode.Fire-fighters should wear full protective clothing and self containedbreathing apparatus (SCBA) operated in positive pressure mode. Water spray maybe used to keep fire exposed containers cool.6. ACCIDENTAL RELEASE MEASURESEmergencyProcedures7. HANDLING AND STORAGEPrecautions for SafeHandlingConditions for SafeStorageCorrosivenessSlippery when spilt. Avoid accidents, clean up immediately.Small spill: Mop up and wash residue to drain with copious amounts of water.Large spill: Contain and place absorbent material onto spillage. Collect andplace into a suitable labelled container. Clean area with water, collectresidue and place into the same container.Dispose of waste according to the applicable local and national regulations.If contamination of sewers or waterways occurs inform the local water andwaste management authorities in accordance with local regulations.Avoid eye contact. Prevent the build-up of vapours or mist in the workingatmosphere. Ensure ventilation is adequate. Keep containers closed when not inuse. Practice good personal hygiene, that is, always wash hands afterhandling, and before eating, drinking, smoking or using the toilet facilities.Store in a cool, dry place, out of direct sunlight. Avoid contact withincompatible materials such as strong oxidising agents. Protect from frost.Not corrosive8. EXPOSURE CONTROLS/PERSONAL PROTECTIONNational ExposureStandardsNo exposure standards have been established for the mixture by the NationalOccupational Health & Safety Commission (NOHSC), Australia. The availableexposure limits for the ingredients are listed below:Australian National Occupational Health And Safety Commission (NOHSC) ExposureStandards:Substance TWA STEL NOTESppm mg/m³ ppm mg/m³Formaldehyde 1 1.2 2 2.5 SenSodium hydroxide - 2 (peak limit) - -Tetrasodium pyrophosphate - 5 - - -National Industrial Chemicals Notification and Assessment Scheme (NICNAS),Australia recommends that NOHSC lower the current exposure standard forformaldehyde to the following:Substance TWA STEL NOTICESppm mg/m³ ppm mg/m³Formaldehyde 0.3 0.36 0.6 0.72 SenTWA (Time Weighted Average): The average airborne concentration of aparticular substance when calculated over a normal eight-hour working day, fora five-day week.STEL (Short Term Exposure Limit): The average airborne concentration over a 15Print Date: 22/11/2012 CS: 1.6.25


Material Safety Data SheetCS: 1.6.25Page: 3of5Infosafe No LQ1TP Issue Date : November 2012 ISSUED by COLGATEProduct Name :COLD POWER ULTRA HDL DETERGENT - REGULAR - FRONT LOADERBiological LimitValuesEngineeringControlsRespiratoryProtectionEye ProtectionHand ProtectionFootwearBody Protectionminute period which should not be exceeded at any time during a normaleight-hour workday.Peak Limitation: A ceiling concentration which should not be exceeded over ameasurement period which should be as short as possible but not exceeding 15minutes.'Sen' Notice: The substance may cause sensitisation by skin contact or byinhalation.No biological limit allocated.No special engineering controls required. However, under industrialapplications, provide sufficient ventilation to keep airborne levels below theexposure limits. Where vapours or mists are generated and exposure standardsare exceeded, the use of respiratory protection, or a local exhaustventilation system is recommended.Not required under normal conditions of use. However for industrialapplications, if engineering controls are not effective in keeping airborneconcentrations below exposure limit, then an approved respirator with areplaceable vapour/mist filter should be used. Reference should be made toAustralian/New Zealand Standard AS/NZS 1715, Selection, Use and Maintenanceof Respiratory Protective Devices; and AS/NZS 1716, Respiratory ProtectiveDevices, in order to make any necessary changes for individual circumstances.Not required under normal conditions of use. However, avoid eye contact.Industrial Applications: The use of safety glasses as appropriate whenhandling large quantities. Refer to Australian/New Zealand Standard AS/NZS1337 - Eye Protectors for Industrial Applications.For extended contact with the liquid wear gloves of impervious material, e.g.PVC, nitrile or laminated film. Reference should be made to Australian/NewZealand Standard AS/NZS 2161.1: Occupational protective gloves - Selection,use and maintenance.Not required under normal conditions of use.Industrial Applications: Safety boots with non-slip soles as required. Referto Australian Standard AS 2210- Safety footwear.Not required under normal conditions of use.Industrial Applications: Suitable impervious protective clothing. Industrialclothing should conform to the specifications detailed in Australian/NewZealand Standard AS 2919: Industrial clothing.9. PHYSICAL AND CHEMICAL PROPERTIESAppearanceOdourMelting PointBoiling PointSolubility in WaterSpecific GravitypH ValueVapour PressureVapour Density(Air=1)ViscosityFlash PointFlammabilityAuto-IgnitionTemperatureFlammable Limits -LowerFlammable Limits -UpperOpaque, blue liquidNot availableNot availableNot availableSoluble1.21 - 1.2510.2 - 11.4Not availableNot available2,000 to 10,000 cps at 25°CNot applicableNon-flammable, however if involved in a fire may release toxic gases.Not availableNot applicableNot applicablePrint Date: 22/11/2012 CS: 1.6.25


Material Safety Data SheetCS: 1.6.25Page: 4of5Infosafe No LQ1TP Issue Date : November 2012 ISSUED by COLGATEProduct Name :COLD POWER ULTRA HDL DETERGENT - REGULAR - FRONT LOADER10. STABILITY AND REACTIVITYChemical StabilityIncompatibleMaterialsHazardousDecompositionProductsHazardousPolymerizationStable under normal conditions of storage, handling and use.Strong oxidising agents.Thermal decomposition may result in the release of toxic and/or irritatingfumes and gases including oxides of carbon, nitrogen, sulphur and phosphorus.Will not occur.11. TOXICOLOGICAL INFORMATIONToxicologyInformationInhalationIngestionSkinEyeChronic Effects12. ECOLOGICAL INFORMATIONEcotoxicityPersistence /DegradabilityMobilityEnviron. ProtectionNo toxicity data is available for this specific product, however the dataavailable for the ingredients are as follows:Formaldehyde:LD50 (Oral, Rat): 500 mg/kgLC50 (Inhalation, Rat): 250 ppm/4HInhalation of mist may result in respiratory irritation.Ingestion of this product may irritate the gastric tract, causing possiblenausea and vomiting.May cause irritation to individuals with sensitive skin.May cause irritation in contact with the eyes, including redness, stinging andtearing.Not availableNot availableNot availableNot available13. DISPOSAL CONSIDERATIONSDisposalConsiderations14. TRANSPORT INFORMATIONTransportInformationIMDG MarinePollutant (MP)15. REGULATORY INFORMATIONRegulatoryInformationPoisons ScheduleDo not discharge product into waterways.The disposal of the spilled or waste material must be done in accordance withapplicable local and national regulations.AustraliaNot classified as Dangerous Goods according to the Australian Code for theTransport of Dangerous Goods by Road and Rail (ADG Code).Marine Transport (IMO/IMDG):Not classified as Dangerous Goods by the criteria of the InternationalMaritime Dangerous Goods Code (IMDG Code) for transport by sea.Air Transport (ICAO/IATA):Not classified as Dangerous Goods by the criteria of the International AirTransport Association (IATA) Dangerous Goods Regulations for transport by air.NoNot classified as Hazardous according to criteria of National OccupationalHealth & Safety Commission (NOHSC), Australia.Not classified as a Scheduled Poison according to the Standard for the UniformScheduling of Medicines and Poisons (SUSMP).Not ScheduledPrint Date: 22/11/2012 CS: 1.6.25


Material Safety Data SheetCS: 1.6.25Page: 5of5Infosafe No LQ1TP Issue Date : November 2012 ISSUED by COLGATEProduct Name :COLD POWER ULTRA HDL DETERGENT - REGULAR - FRONT LOADER16. OTHER INFORMATIONDate of preparationor last revision ofMSDSContact Person/PointMSDS Created: November 201224Hr Emergency ResponseAustralia- 1800 638 556New Zealand- 0800 764 766...End Of MSDS...© Copyright ACOHS Pty LtdCopyright in the source code of the HTML, PDF, XML, XFO and any other electronic files rendered by an Infosafe system for Infosafe MSDS displayed is the intellectualproperty of Acohs Pty Ltd.Copyright in the layout, presentation and appearance of each Infosafe MSDS displayed is the intellectual property of Acohs Pty Ltd.The compilation of MSDS's displayed is the intellectual property of Acohs Pty Ltd.Copying of any MSDS displayed is permitted for personal use only and otherwise is not permitted. In particular the MSDS's displayed cannot be copied for the purpose ofsale or licence or for inclusion as part of a collection of MSDS without the express written consent of Acohs Pty Ltd.Print Date: 22/11/2012 CS: 1.6.25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!