anesthesia guideHow to Select Anesthesia EquipmentEvacuation System Selection GuideEvacuation Systems are necessary when waste gas from the animal still contains anesthetic agents. It mustbe removed from the exhausted gas before it can be released into the environment. What kind of evacuationsystems are available for waste anesthesia gas? Harvard Apparatus has several options to choose from. Selectthe system that best suits your application.F/Air Evacuation Pure-Guard Lab Animal AES Active GasSystem Fluovac System Monitor System Evacuation System Evacuation SystemCanister Style Canister Style Canister Style Charcoal Cartridge Passive Flow SystemEvacuation System Evacuation System Evacuation SystemEach canister can be used for For use with a single For use with a single Can be used with up to For use with a single1 anesthesia machine, multiple anesthesia machine anesthesia machine 6 anesthesia machines anesthesia machinecanisters for multiple machinesEach canister can remove Each canister can remove 70 grams 1 lb No limitation on amount50 grams of pure 200 grams of halogenated of anesthetic agenthalogenated anesthetic gases anesthetic gasesPassively scavenges waste Actively scavenges waste Passively scavenges waste Actively or passively Active flow collects gasscavenges wastefrom anesthesia machineDoes not require Does not require Does not require Maybe be vented directly Must be vented to aventing to a hood venting to a hood venting to a hood to room when using charcoal fume hood or outsidecartridge or to a hood if desired. charcoal filtrationEasy disposal in Easy disposal in Easy disposal in Charcoal may be disposed Two standard inlet portregular trash regular trash regular trash of in regular trash and on exhaust port hookup to existing equipmentCanister is System Requires Fluosorber Canisters Requires Enviro-Pure Canisters Requires charcoal refill cartridges No cartridges requiredsee page F34 see page F46 see page F35 see page F33 see page F34for complete details for complete details for complete details for complete details for complete detailsanesthesia guide RespirationHarvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.comF25

anesthesia guideEvacuation System Selection Guide (continued)Evacuation System Selection GuideHarvard Apparatus offers five basic evacuation/scavenging systems that work with our anesthesia setups. A brief description of these systemsand their components are listed below. Three of the systems have multiple configurations based on your anesthesia setup. The basiccomponents are the same, just connections and adapters change with each configuration.F/Air EvacuationThis evacuation system is a simpleand economical way of removinganesthetic gases. The activecharcoal in the canister removesthe waste gas. The used canistercan be tossed in the trash fordisposal. See page F34 forcomplete details.Fluovac SystemThe Fluovac Systems activelyscavenges anesthetic waste anddoes not require venting to ahood. It uses the FluosorberCanisters, which when full, can bedisposed of in the regular trash.See page F46 for complete details.Respirationanesthesia guideConfiguration Components Order #1-A F/Air Canisters, case of 8 PY2 72-1294Tubing Connector PY2 60-5251Rodent Circuit Set PY2 72-3026Respiratory Adaptor PY2 72-28891-B F/Air Canisters, case of 8 PY2 72-1294Tubing Connector PY2 60-5251Active Gas EvacuationThis evacuation system removesthe waste gas from the anesthesiacircuit and vents it to a wastesystem, ventilation hood or theoutdoors. See page F34 forcomplete details.Configuration Components Order #3-A Fluovac System 110V (230V) PY2 34-0388/PY2 34-0387Fluosorber Canisters PY2 34-0415Pure-Guard MonitorSystemThe Pure-Guard System is similarto the F-Air Canister Systems, butit removes all the guess work. Thesystem monitors the status of thecharcoal canister and alarms youwhen it requires changing. Seepage F35 for complete details.Configuration Components Order #2-A AES Active Gas Evacuation PY2 72-3065Tubing PY2 72-3093Male Adaptor, 19 mm PY2 72-3085Rodent Circuit Set PY2 72-3026Respiratory Adaptor PY2 72-28892-B AES Active Gas Evacuation PY2 72-3065Tubing PY2 72-3093Male Adaptor, 19 mm PY2 72-30852-C AES Active Gas Evacuation PY2 72-3065Tubing PY2 72-3093Configuration Components Order #4-A Pure-Guard Monitor System PY2 72-8119Rodent Circuit Set PY2 72-3026Respiratory Adaptor PY2 72-28894-B Pure-Guard Monitor System PY2 72-8119Lab Animal EvacuationSystemThis evacuation system is suitablefor evacuating waste anestheticgases from 1 to 6 stations. It wasdesigned for those facilities to donot have built-in evacuation systemsor fume hoods. See page F33 forcomplete details.Configuration Components Order #5-A Lab Animal Evacuation System PY2 72-3066Charcoal Refill PY2 72-3067F26Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com

<strong>anesthesia</strong> <strong>guide</strong>How to Select Anesthesia EquipmentEvacuation System Selection GuideEvacuation Systems are necessary when waste gas from the animal still contains anesthetic agents. It mustbe removed from the exhausted gas before it can be released into the environment. What kind of evacuationsystems are available for waste <strong>anesthesia</strong> gas? Harvard Apparatus has several options to choose from. Selectthe system that best suits your application.F/Air Evacuation Pure-Guard Lab Animal AES Active GasSystem Fluovac System Monitor System Evacuation System Evacuation SystemCanister Style Canister Style Canister Style Charcoal Cartridge Passive Flow SystemEvacuation System Evacuation System Evacuation SystemEach canister can be used for For use with a single For use with a single Can be used with up to For use with a single1 <strong>anesthesia</strong> machine, multiple <strong>anesthesia</strong> machine <strong>anesthesia</strong> machine 6 <strong>anesthesia</strong> machines <strong>anesthesia</strong> machinecanisters for multiple machinesEach canister can remove Each canister can remove 70 grams 1 lb No limitation on amount50 grams of pure 200 grams of halogenated of anesthetic agenthalogenated anesthetic gases anesthetic gasesPassively scavenges waste Actively scavenges waste Passively scavenges waste Actively or passively Active flow collects gasscavenges wastefrom <strong>anesthesia</strong> machineDoes not require Does not require Does not require Maybe be vented directly Must be vented to aventing to a hood venting to a hood venting to a hood to room when using charcoal fume hood or outsidecartridge or to a hood if desired. charcoal filtrationEasy disposal in Easy disposal in Easy disposal in Charcoal may be disposed Two standard inlet portregular trash regular trash regular trash of in regular trash and on exhaust port hookup to existing equipmentCanister is System Requires Fluosorber Canisters Requires Enviro-Pure Canisters Requires charcoal refill cartridges No cartridges requiredsee page F34 see page F46 see page F35 see page F33 see page F34for complete details for complete details for complete details for complete details for complete details<strong>anesthesia</strong> <strong>guide</strong> RespirationHarvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.comF25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!