Quality & Metering<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>INDEXQNA500Modular power <strong>quality</strong> analyzer· ··············································································· Q2-7M-8IO / M-8IORDevice module with 8 inputs and 8 digital outputs· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Q2-9QD-500HMI monitoring module for QNA500· ·········································································· Q2-10QNA 413<strong>Power</strong> <strong>quality</strong> analyzer ····················································································· Q2-11QNA 412<strong>Power</strong> <strong>quality</strong> analyzer that measures voltages and currents· ······················································· Q2-14QNA-PPortable power <strong>quality</strong> analyzer ·············································································· Q2-17CAVASingle-phase power <strong>quality</strong> <strong>analyzers</strong>· ········································································· Q2-19Q2-2


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>Analizadores de calidad de suministroThe transport of electrical energy is subjectto many variations and factors that cancause the <strong>quality</strong> of the supply voltage tonot always be as desired. Several factors,such as inclement weather, excessive distancesin the distribution lines or the connectionof loads with excessive distortionare some of the causes that may affect theproper <strong>quality</strong> of the electric supply.Industries use increasingly more sophisticatedprocesses with a greater numberof control, automation and regulation elements,allowing companies to execute suchprocesses automatically and be more competitive.In general, said loads are very sensitiveto voltage variations, which can leadto faulty performance and critical problemsin processes. Meanwhile, companies areincreasingly investing in the measurementand control of the <strong>quality</strong> of the electricsupply to avoid the costs generally associatedwith productive processes.It has become essential to control not onlythe costs associated with the supply’s lackof continuity, but also those associated withits lack of <strong>quality</strong>. It is of vital importanceto supervise the smooth operation of theinstallation and the equipment connectedto it, and to conduct proper energy managementto avoid the unnecessary overconsumption.The globalization of markets also givesthe various actors involved in the electricalenergy generation, transport and consumptionprocesses the need to talk on equalterms in order to face the new challengesahead that come along with the optimisationof both distribution lines and electricalinstallations. The future of Smart Grids iscurrently making a strong impact on the entirenetwork of electrical distribution lines,allowing automation of substations and optimisingof existing resources.Measurement in various points on the distributionlines makes it necessary to haveequipment that guarantees, on the onehand, the absolute validity of the measurement(in compliance with the IEC-61000-4-30 standard), and on the other hand,proven robustness when implementedin complex environments. We are talkingabout equipment of reference for utilitiesthroughout the world in very different environmentsand distribution lines. At thesame time, companies are operating inincreasingly global environments, forcingthem to be more competitive and to optimisetheir processes. Therefore, the electricaldisturbances affecting productive processesin companies must be analysed andstudied with the purpose of improving andprotecting installations against such disturbances.Q.2Q2-3


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>AplicationsDefinitionThe QNA power <strong>quality</strong> <strong>analyzers</strong>comply with the strictestinternational standards. Currently,the IEC-61000-4-30standard specifies the way inwhich this type of equipmentmust take the measurements ofa set of parameters. The standardhas defined 3 classes:Firstly, class A is reserved forthe most accurate equipment,which must comply with thestrict measurement methodologyand have a high degreeof accuracy in all parametersmeasured. The equipmentcertified with class A accuracyin this standard will be usedas pattern elements and canbe used to resolve any type ofdispute.Secondly is class S, which followsthe same measurementmethod as class A equipmentbut which does not require thesame level of accuracy. Thisequipment is normally used atindustry connection points withthe distribution lines or in substations.<strong>Circutor</strong> has electricpower <strong>quality</strong> <strong>analyzers</strong> forboth classes aimed at mee-ting the needs of industries orfor any customer that requiresan exhaustive analysis of theirelectrical installation in orderto improve productivity andavoid problems caused byelectrical disturbances.The log of historical valuesgives us an insight into theevolution and tendency of thesupply voltage and the powerconsumed in the electrical installation,also letting us identifyanomalies that may interferewith the optimum performanceof the machines and systemsconnected to the network.Any voltage event can beperceived to cause improperfunctioning in certain types ofelectronic equipment. Loggingthese incidents according tothe network <strong>quality</strong> class AIEC-61000-4-30 standard letsus accurately identify the causesof malfunctions and thustake the necessary correctivemeasures to minimize productivitycosts.The new QNA500 seriesmeets the most necessaryrequirements to perform a correctanalysis of the electricalpower <strong>quality</strong>, providing theuser with precise and detailedinformation on the evolutionof all electrical variables,as well as any disturbancesthat could affect the smoothoperation of the machinesconnected to the electricalnetwork.Also, using CIRCUTOR’s<strong>Power</strong>Vision + and <strong>Power</strong>Studiosoftware, the usercan automate many of theanalyzer’s functions, as wellas customize alarms, SCADAscreens and even run customizedreports in accordance withEN-50160 <strong>quality</strong> standardsand other applicable regulations.Big industry and large energyconsumersThe network <strong>quality</strong> studyin the network connectionpoint is particularly importantfor the optimisation ofthe productive processes ofcompanies. The detectionof any network disturbancesand assessment of the contentof harmonic distortion ininstallations and the energyconsumed are the parametersthat must be assessedin any installation, with thepurpose of improving itsperformance. CIRCUTOR’ssystems offer the solutionsrequired to cater for theseneeds. Notification via e-mailor SMS alarms can be sentwhen a programmed eventtakes place. This minimisesthe problem in many cases,since different actions can beimplemented on the differentburdens, thus avoiding greaterproblems associated toproduction processes.Multi-point buildingsThe QNA500 lets you combinethe measurements takenin different buildings of asingle owner (ex. supermarkets,bank branches) in orderto collectively evaluate thesmooth operation and theproductivity levels that existthroughout the network ofestablishments. In this way,tracking and precautionarymeasures can be performedon electrical installations withpreventive maintenance thatcan avoid future incidents.Energy distributorsCurrently, many utilitiesthroughout the world useQNA power <strong>quality</strong> <strong>analyzers</strong>to analyze the behaviourof the <strong>quality</strong> of wavesin distribution lines. The highreliability and robustness ofthese <strong>analyzers</strong>, as well asthe CIRCUTOR’s proven experiencein measuring electricalparameters, lets usoffer products customized tothe needs of electrical energytransport and distributioncompanies.Their installation in HV or MVdistributioncells and remotemeasuring lets us obtain allthe necessary information ina short time and even lets usintegrate these <strong>analyzers</strong> inimprovements to sub-stationsthemselves within the evolutionof Smart Grids.Q2-4


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>Product selection tableEquipmentCommunicationsVoltageFlickerHarmonics and THDUnbalanceEventsCurrent<strong>Power</strong> (act / react)FP<strong>Power</strong> (act / react)Digital inputs6 voltage channelsAssemblyPageQNA 500 8IORS-232 / RS-485,Ethernet, WebServer, Mail Server• • 50 • • • • • • • • DIN Rail 7QNA -413RS-232 / RS-485 • • 50 • • PanelGPRS / GSM / RS-232 • • 50 • • Panel7RS-232 / RS-485 • • 50 • • • • • • • PanelQNA -412GPRS / GSM / RS-232 • • 50 • • • • • • • Panel13ETHERNET • • 50 • • • • • • • PanelQNA-PTETHERNET • 50 • • • • • • Panel 16RS-232 • • 50 • • • • • • • PortableQNA-PGSM / RS-232 • • 50 • • • • • • • Portable19CAVARS-232 • • 20 (*) (*) (*) Portable 21(*) According to type.Q2-5


Q2-6<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA500Modular power <strong>quality</strong> analyzerDescriptionFeaturesQNA500 is a modular power <strong>quality</strong>analyzer designed to measure and logthe main electrical parameters and thetransient disturbances. The measurementis taken as an RMS value by 5 ACvoltage inputs and 4 AC current inputs.(through current transformers I5 A). Ithas 2 GB of memoryApplicationAuxiliary <strong>Power</strong> Supply (BASE)<strong>Power</strong> supply voltageFrequencyConsumptionAuxiliary battery power supply (BASE)TypeBattery lifeVoltage measurement (QNA500)Measurement circuit90 - 300 V ac- 100 - 300 V dc50 ... 60 Hz7 W / 11 VA (BASE)4 W / 5 VA (QNA500)6 W / 10 VA (8IO)Removable battery15 minutes of continuous operation (QNA500)1 minute of continuous operation (8IO)3 or 4 wiresQNA500 is designed to supervise theelectrical installation and the problemsrelated to the electrical power <strong>quality</strong>,with the objective of controlling the productiveprocesses and managing incidents.Its easy integration into SCADAapplications and its interaction with marketPLC software lets it form part of morecomprehensive data acquisition systemsand report the information required byusers at all times.Its modularity and the addition of 8IOmodules also let the user control energyconsumption, the statuses of switches orloads, the sending of alarms and eventhe connection/disconnection of loadsbased on configurable conditions.Along with the CIRCUTOR <strong>Power</strong>Vision+software, the user can configure customizedreports to evaluate the smooth operationof the electrical installation, andcan apply standards like the EN-50160,CBEMA and UNIPEDE event tables, andothers. By automating this information, theuser can display the most important informationwith just one click, in order to carryout the corresponding analysis.Measurement range0 ... 500 V p-n/ 0 ... 866 V p-pOther voltagesThrough the measuring transformersMaximum voltage of the1500 V ac(p-p)permanent measurementMaximum voltage of the1.2/50 μS (8/20 μS) 6 kVinstantaneous measurementFrequency42.5 ... 69 HzSampling frequency512 samples/cycleCurrent measurement (QNA500)Measurement range1 ... 120 % I n... I n= 5 AMaximum current120% of I n(for I n= 5A, I max= 6A) permanent,100A t


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA500Modular power <strong>quality</strong> analyzerVariablesRegistry variables Unit L 1 L 2 L 3 IIIPhase-phase and phase-neutral voltage (RMS, maximum, minimum) V • • • •Current (RMS, maximum, minimum) A • • • •Neutral current (RMS, maximum, minimum) A •Neutral ground voltage (RMS, maximum, minimum) V •Frequency (RMS, maximum, minimum) Hz • • •Active power (RMS, maximum, minimum) kW • • • •Inductive reactive power (RMS, maximum, minimum) kvar • • • •Capacitive reactive power (RMS, maximum, minimum) kvar • • • •Apparent power (RMS, maximum, minimum) kVA • • • •Maximum demand kW • • •<strong>Power</strong> factor (RMS, maximum, minimum) • • • •Crest factor (voltage and current) V or A • • •K Factor • • •Active energy kWh • • • •Inductive reactive energy kvarh • • • •Capacitive active energy kvarh • • • •Voltage THD or TDD (RMS, maximum, minimum) % • • •Current THD or TDD (RMS, maximum, minimum)) % • • •Voltage harmonics (up to 50th order) V Harm • • •Current harmonics (up to 50th order) A Harm • • •Voltage interharmonics (up to 50th order) V Harm • • •Current interharmonics (up to 50th order) A Harm • • •Flicker (PST) • • •Gaps % • • •Interruptions % • • •Overvoltage % • • •Voltage transients • • •Current transients • • •Voltage Unbalance • • •Current Unbalance • • •ReferencesEnergyTransients Inputs / Impulse Demand Server MailTypeCode accuracy Harmonic Events logOutputs control panel control WEB ServerQNA500 Q20911 0.2 50 • • - • •QNA500 8IO Q20912 0.2 50 • • 8 / 8 digital • • •QNA500 8IOR Q20913 0.2 50 • • 8 / 8 digital • • • •Each unit is made up of a BASE module (power supply) + Measurement module + relay module (in accordance with the type)DimensionsConnections174144173.3154.412548 64 32For other connections consult the manual.Q2-8


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>M-8IO / M-8IORDevice module with 8 inputsand 8 digital outputsDescriptionFeaturesM-8IO / M-8IOR is a device with 8 programmableinputs and 8 digital programmableoutputs (transistor or relay). Thedevice has an integrated Web serverenabling it to perform all the requiredconfiguration. The digital inputs enableit to count the pulses sent by other devices(ex. energy, water or gas meters) aswell as log the status changes of externalrelays (ex. MCB or PLC). The digitaloutputs enable it to configure alarms,energy pulses and even remote controlfunctions.Being another SGE system module letsseveral 8IO modules connect to eachother (up to 4) or with other SGE modules(ex. QNA500) to extend the product'sfunctionality.ApplicationM-8IO permits interaction with other SGEmodules, enabling comprehensive controlof the electrical installation by centralizingof the energy pulses of meters, controllingthe alarms that may be produced at thehead-end of the electrical installation andeven sending these alarms to other SCA-DA or PLC systems.Auxiliary <strong>Power</strong> Supply (BASE)<strong>Power</strong> supply voltageFrequencyConsumptionAuxiliary battery power supply (BASE)TypeBattery lifeDigital inputs (8IO)Working voltageMinimum signal widthElectrical consumption (per input)Digital outputs (8IO)TypeWorking voltageWorking currentPulse weightDigital outputs per Relay (8IOR)TypeNominal voltageNominal currentMemoryProcessorSampling frequencyConverterConnectionMaximum cross-section of the cableReferencesM-8IOM-8IOR90 - 300 V a.c.- 130 - 380 V d.c.50 ... 60 Hz7 W / 11 VA (BASE)4 W / 5 VA (QNA500)6 W / 10 VA (8IO)Removable battery1 minute of continuous operation (8IO)12 - 18 V dcConfigurable2.5 mWOptocoupled250 V130 mAConfigurableRelay250 V ac/ 30 A dc6 A512 samples/cycle24 bits2.5mm 2 (power supply)1mm 2 (inputs / outputs)Q20902Q209032Gb (MicroSD card)Q2-9


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QD-500HMI monitoring module for QNA500DescriptionFeaturesQD-500 is an HMI monitor that lets youdisplay all the variables for the QNA500power <strong>quality</strong> analyzer. The monitorcommunicates using a RS-232 port withan analyzer and displays all the electricalinstallation's parameters, includingvoltage, current, power, energy, THDand events.<strong>Power</strong> Supply<strong>Power</strong> supply voltage24 V dcConsumption5 WEnvironmental conditionsOperating temperature 0 ... 50 ºCRelative humidity10 ... 85 % (without condensation)Build featuresDisplay typeTFT color LCD 256 colorsDisplay size 7”ResolutionBacklightProcessorMemoryCommunication portDegree of protectionDimensionsPanel dimensionsWeight800 x 480 pixelsLEDARM920T (32 bit RISC) 200 MHz16 Mb (Flash), 32 Mb (RAM)USB, RS-232, RS-485IP 65F203,5 x 153,5 x 42 mm192 x 138 mm0,80 KgReferencesQD-500Q20915ApplicationDimensionsQD-500 lets you monitor the main instantaneousvalues of the QNA500 electricpower <strong>quality</strong> analyzer, in order to find outthe status of the installation when the useris in the transformer substation or in thesubstation.Q2-10


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA 413<strong>Power</strong> <strong>quality</strong> analyzerDescriptionCharacteristicsQNA 413 is a state-of-the-art power <strong>quality</strong>analyzer certified as a class A device, in compliancewith the IEC-61000-4-30 Standard. Ittakes measurements in compliance with theinternational standard and has a high degreeof accuracy. It can be used to analyze the<strong>quality</strong> of supply (voltage, flicker, harmonics,events, etc.) in any installation. The mostcommon cases are sub-stations or transformationcentres and points where companiesare connected to the network.Application}}Real-time supervision and continuousrecording of the power supply <strong>quality</strong> in anymeasurement point.}}Detection and instantaneous recording ofall events (in compliance with the IEC Standards)detected in the measurement point. Itcan be used to detect the origin of events toimplement the necessary actions and carryout the preventive maintenance actions,in order to optimize the performance of theinstallation, thus increasing the company'sproductivity.}}It is certified as class A in compliance withthe IEC-61000-4-30 international standard,allowing it to define the <strong>quality</strong> of supply, regardlessof the country and area of distribution.<strong>Power</strong> circuit<strong>Power</strong> supply rangeConsumptionFrequencyAuxiliary power circuitBatteryAutonomyVoltage measurement circuitNominal voltageOther voltagesFrequencySampling frequencyConsumption of the voltage per phase circuit100 - 400 Vac (± 30 %) / 90 - 730 Vdc16 V·A / 8 W50 - 60 HzNi MHConfigurable, up to 9999 s of continuous operation3 x 500 / 866 Vac (for 4-wire connections)3 x 500 Vac (for 3-wire connections)Through the measurement transformers42.5 ... 69 Hz14.130 kHz0.3 V·AAccuracyVoltage 0.1 % U n(IEC-61000-4-30 class A)Unbalance ± 0.15 % (IEC-61000-4-30 class A)Flicker 5 % (IEC-61000-4-15, IEC-61000-4-30 class A)HarmonicsIEC-61000-4-7 class I, IEC-61000-4-30 class ACommunicationsRS-232 / RS-485, GPRS / GSM / RS-232Data memorySize2 MBSetupRotary (FIFO)Ambient conditionsUsage temperature 0 ºC ... +50 ºCStorage temperature -20 ºC ... + 70 ºCBuild featuresEnclosure In compliance with DIN 43859Differential IP 51Dimensions327 x 176 x 96 mmWeight2.3 kgSafetyEN-61010-1 category III 600 VQ2-11


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA 413<strong>Power</strong> <strong>quality</strong> analyzerDimensionsStandardsEN 60664, EN 61036, VDE 110, UL 94Electromagnetic emissionElectromagnetic immunityEN 61000-3-2 Harmonics EN 50082-2 Industrial immunityEN 61000-3-3 Voltage fluctuations EN 61000-4-2 Electrostatic dischargeEN 55022 class B Driven ENV 50140 EM Radiated field of RFEN 55022 class A Radiated EN 61000-4-4 Quick temporary burstsEN 50081-2 Industrial emission ENV 50141 RF in common mode- - EN 61000-4-5 Shockwave- - EN 61000-4-8 50 Hz Magnetic field- - EN 61000-4-11 <strong>Power</strong> supply interruptionsReferencesVoltageCurrent<strong>Power</strong> ratingEnergyFlickerHarmonicsand THDUnbalanceEventsCertificate Communications Type Code• • 50 • • Class A RS-232 / RS-485 QNA-413 RS232/RS485 Q20411• • 50 • • Class A GPRS / GSM / RS-232 QNA-413 GSM-Free Q20413Distribution of memoryType of file Default storage capacity Data stored*.STD 33 days Voltage, flicker, harmonics and unbalance*.EVQ minimum of 342 events Measurement events (overvoltages, voltage gaps and interruptions)*.EVE 4655 records Events related to the analyzer (change of setup, change of hour, etc.)*.H24 32 days Data for the statistical study of the evolution of harmonics every 24 hours*.STP 16 weeks Weekly statistical voltage values, THD (U), flicker, frequency and unbalanceLa distribución de la memoria es flexible y configurable por el usuario.Q2-12


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA 413<strong>Power</strong> <strong>quality</strong> analyzerConnectionsLV 4 wiresMV 3 wiresL1L1L2L2L3L3NAB A B A Bab a b a b21 22 23 24 25 26 27 28 29 30 31 32 33 34 351 2 3 4 5 6 7 89R2R121 22 23 24 25 26 27 28 29 30 31 32 33 34 35R2 R11 2 3 4 5 6 7 8 9AlimentaciónauxiliarAlimentaciónauxiliarQ2-13


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA 412<strong>Power</strong> <strong>quality</strong> analyzer that measuresvoltages and currentsCharacteristics<strong>Power</strong> circuitDescriptionQNA 412 is a state-of-the-art power <strong>quality</strong>analyzer certified as a class A device, in compliancewith the IEC-61000-4-30 Standard.It takes measurements in compliance withthe international standard. In addition to theanalysis of the variables related to the <strong>quality</strong>of supply (voltage, flicker, harmonics, events,etc.), it also acts as a network analyzer andredundant counter, since it can be usedto analyse the current signals, power consumed(active and reactive), the power factorand active and reactive energy consumed orgenerated with an accuracy of 0.2S, as in thecase of the high-precision energy meters.Application}}Supervise the optimum operation of electricinstallations and transformers. The LV connectionenables the supervision of the saturationof the power transformer and the reactiveenergy consumed in each installation.}}Detection and instantaneous recording ofall events (in compliance with the IEC Standard)detected in the measurement point. Itcan be used to detect the origin of events toimplement the necessary actions and carryout the preventive maintenance actions,in order to optimize the performance of theinstallation, thus increasing the company'sproductivity.}}It can work as a redundant counter tocheck the energy charged by the company.The unit is fully sealable, so that it can not betampered with.<strong>Power</strong> supply rangeConsumptionFrequencyAuxiliary power circuitBatteryAutonomyVoltage measurement circuitNominal voltageOther voltagesFrequencySampling frequencyConsumption of the voltage per phase circuitCurrent measurement circuitMeasurement marginConsumption of the circuit, current per phaseMaximum sampling frequencyEnergy meter, maximum value100 - 400 Vac (± 30 %) / 90 - 730 Vdc16 V·A / 8 W50 - 60 Hz (QNA 412-T type, only 50 Hz)Ni MHConfigurable, up to 9999 s of continuous operation3 x 500 / 866 Vac (for 4-wire connections)3 x 500 Vac (for 3-wire connections)Through the measurement transformers42.5 ... 69 Hz14.130 kHz0.3 V·A.../5 (6) A (input with galvanic insulation).../1 (1.2) A (input with galvanicinsulation).../2 V.../ITF-EXTERIOR0.01 V·A14.130 kHz1 999 999 kW·h (rotates)AccuracyVoltage 0.1 % U n(IEC-61000-4-30 class A)Current 0.1 % I n(IEC-61000-4-30 class A)EnergyClass 0.2S in accordance with EN-62053-22Unbalance ± 0.15 % (IEC-61000-4-30 class A)Flicker 5 % (IEC-61000-4-15, IEC-61000-4-30 class A)HarmonicsIEC-61000-4-7 class I, IEC-61000-4-30 class ACommunicationsRS-232 / RS-485, GPRS / GSM / RS-232, EthernetData memorySize4 MBSetupRotary (FIFO)Ambient conditionsUsage temperature 0 ºC ... +50 ºCStorage temperature -20 ºC ... + 70 ºCBuild featuresEnclosure In compliance with DIN 43859Differential IP 51Dimensions327 x 176 x 96 mmWeight2.3 kgSafetyEN-61010-1 category III 600 VQ2-14


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA 412<strong>Power</strong> <strong>quality</strong> analyzer that measuresvoltages and currentsDimensionsStandardsEN 60664, EN 61036, VDE 110, UL 94Electromagnetic emissionElectromagnetic immunityEN 61000-3-2 Harmonics EN 50082-2 Industrial immunityEN 61000-3-3 Voltage fluctuations EN 61000-4-2 Electrostatic dischargeEN 55022 class B Driven ENV 50140 EM Radiated field of RFEN 55022 class A Radiated EN 61000-4-4 Quick temporary burstsEN 50081-2 Industrial emission ENV 50141 RF in common mode- - EN 61000-4-5 Shockwave- - EN 61000-4-8 50 Hz Magnetic field- - EN 61000-4-11 <strong>Power</strong> supply interruptionsReferencesVoltageCurrent<strong>Power</strong> ratingEnergyFlickerHarmonics and THDUnbalanceEventsCertificate... / 5 A... / 1 A.../2 V.../ITF-EXTERIORRMS GráphForma onda eventoCommunications Type Code• • • • • • • • A • RS-232 / RS-485.../5 A Q20510• • • • • • • • A • RS-232 / RS-485 .../1 A Q20510 001QNA-412 RS232/RS485• • • • • • • • A • RS-232 / RS-485 .../2 V Q20510 002• • • • • • • • A • RS-232 / RS-485 .../ITF-EXTERIOR Q20510 003• • • • • • • • A • GPRS / GSM / RS-232.../5 A Q20530• • • • • • • • A • GPRS / GSM / RS-232 .../1 A Q20530 001QNA-412 GPRS/RS232• • • • • • • • A • GPRS / GSM / RS-232 .../2 V Q20530 002• • • • • • • • A • GPRS / GSM / RS-232 .../ITF-EXTERIOR Q20530 003• • • • • • • • A • Ethernet.../5 A Q20542• • • • • • • • A • Ethernet .../1 A Q20542 001QNA-412 Ethernet• • • • • • • • A • Ethernet .../2 V Q20542 002• • • • • • • • A • Ethernet .../ITF-EXTERIOR Q20542 003Q2-15


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA 412<strong>Power</strong> <strong>quality</strong> analyzer that measuresvoltages and currentsDistribution of memoryType of file Default storage capacity Data stored*.STD 74 days Voltage, flicker, harmonics and unbalance*.EVQ minimum of 342 events Measurement events (overvoltages, voltage gaps and interruptions)*.EVE 4655 records Events related to the analyzer (change of setup, change of hour, etc.)*.WAT 32 days Active, reactive L and reactive C*.H24 32 days Data for the statistical study of the evolution of harmonics every 24 hours*.STP 16 weeks Weekly statistical voltage values, THD (U), flicker, frequency and unbalanceConnectionsLV 4 wiresMV 3 wiresQ2-16


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA-PPortable power <strong>quality</strong> analyzerDescriptionCharacteristicsPortable electric power <strong>quality</strong> analyzer thatmeasures and records the data in compliancewith the class A IEC-61000-4-30 Standard.Specially designed for outdoor measurementsor in situations that require a highlyaccurate and very robust unit.The QNA-P enclosure has an IP 67 degree ofprotection, which guarantees its robustnessto strong impacts. The QNA-P analyzer hasbeen tailor-made with clips and it has a widerange of flexible (LV measurements) andrigid clips (LV and MV Measurements). Theinternal switches can be adapted to any typeof network (3/4 wires), with the use of its rigid(CP type) and flexible (C-FLEX type) clips.Application}}The QNA-P portable analyzer is highlyversatile and can combine rigid and flexiblenucleus clips. Its robustness makes it idealfor the intake of measurements in placessubject to severe weather conditions.}}The unit has been specially designed forthe execution of audits and revisions, since ithas been certified as Class A, in compliancewith the IEC-61000-4-30 Standard, so thatthe measurements taken can be used for anytype of verification; a pattern element is usedduring the intake process.}}The internal GSM type can also be usedto download the information remotely anddraft a report with the data, even before removingthe analyzer, which avoids the needof travelling to the installations.<strong>Power</strong> circuit<strong>Power</strong> supply rangeConsumptionFrequencyAuxiliary power circuitBatteryAutonomyVoltage measurement circuitNominal voltageOther voltagesFrequencySampling frequencyConsumption of the voltage per phase circuit100 - 240 Vac16 V·A / 8 W50 - 60 HzNi MHConfigurable, up to 9999 s of continuous operation3 x 500 / 866 Vac (for 4-wire connections)3 x 500 Vac (for 3-wire connections)Through the measurement transformers42.5 ... 69 Hz14.130 kHz0.3 V·ACurrent measurement circuitMeasurement marginDepending on the clipMaximum current1.2 I nMaximum sampling frequency14.130 kHzEnergy meter, maximum value1 999 999 kW·h (rotates)AccuracyVoltage 0.1 % U n(IEC-61000-4-30 class A)Current 0.1 % I n(IEC-61000-4-30 class A)EnergyClass 0.2S in accordance with EN-62053-22Unbalance ± 0.15 % (IEC-61000-4-30 class A)Flicker 5 % (IEC-61000-4-15, IEC-61000-4-30 class A)HarmonicsIEC-61000-4-7 class I, IEC-61000-4-30 class ACommunicationsRS-232 / RS-485, GPRS / GSM / RS-232Data memorySize4 MBSetupRotary (FIFO)Ambient conditionsUsage temperature -20 ºC ... +65 ºCBuild featuresEnclosureSealed enclosureDifferential IP 67Dimensions470 x 357 x 176 mmWeight6.7 kgSafetyEN-61010-1 category III 600 VQ2-17


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>QNA-PPortable power <strong>quality</strong> analyzerDimensionsStandardsEN 60664, EN 61036, VDE 110, UL 94IEC-61000-4-30 class A QualityIEC-61000-4-7 class IHarmonicsIEC-61000-4-15FlickerElectromagnetic emissionElectromagnetic immunityEN 61000-3-2 Harmonics EN 50082-2 Industrial immunityEN 61000-3-3 Voltage fluctuations EN 61000-4-2 Electrostatic dischargeEN 55022 class B Driven ENV 50140 EM Radiated field of RFEN 55022 class A Radiated EN 61000-4-4 Quick temporary burstsEN 50081-2 Industrial emission ENV 50141 RF in common mode- - EN 61000-4-5 Shockwave- - EN 61000-4-8 50 Hz Magnetic field- - EN 61000-4-11 <strong>Power</strong> supply interruptionsReferencesAnalyzer Clips Type CodeQNA-412 RS232/RS485 3 x C-FLEX 10k/1k/100 A - 55 mm Kit 1 QNA-P RS Q20711QNA-412 GPRS/RS232 3 x C-FLEX 10k/1k/100 A - 55 mm Kit 1 QNA-P GPRS Q20731QNA-412 RS232/RS485 3 x C-FLEX 10k/1k/100 A - 55 mm, kit 3 CP-5 A and 1 x CPR-500 Kit 2 QNA-P RS Q20712QNA-412 GPRS/RS232 3 x C-FLEX 10k/1k/100 A - 55 mm, kit 3 CP-5 A and 1 x CPR-500 Kit 2 QNA-P GPRS Q20732Distribution of memoryType of file Default storage capacity Data stored*.STD 74 days Voltage, flicker, harmonics and unbalance*.EVQ minimum of 342 events Measurement events (overvoltages, voltage gaps and interruptions)*.EVE 4655 records Events related to the analyzer (change of setup, change of hour, etc.)*.WAT 32 days Active, reactive L and reactive C*.H24 32 days Data for the statistical study of the evolution of harmonics every 24 hours*.STP 16 weeks Weekly statistical voltage values, THD (U), flicker, frequency and unbalanceQ2-18


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>CAVASingle-phase power <strong>quality</strong> <strong>analyzers</strong>DescriptionCharacteristicsThe CAVA series <strong>analyzers</strong> are measurementequipment that can analyze and recordthe main supply <strong>quality</strong> parameters of anelectricity network. There are three types withdifferent measurement capacities. The basicperformance features are stated next:}}Analysis of 100% of the voltage and currentcycles}}Optional measurement of currents between2 A and 10 000 A with different currentsensing clips}}Large storage capacity}}Easy installation and programming}}Programming and extraction of data witha PC}}<strong>Power</strong>Vision software used to analysemeasurements.ApplicationThe CAVA single-phase analyzer has beenspecially designed for the intake of LVmeasurements during long periods of time,with the purpose of determining the supply<strong>quality</strong> existing in the measurement point(voltage, flicker, harmonics, etc). It is theperfect product to analyze the difference involtage between the start and end of distributionlines. Its easy installation and the user-oriented<strong>Power</strong>Vision software can beused to analyze any information and applythe <strong>quality</strong> standards (for ex., EN-50160) tothe measurements taken to determine thedegree of <strong>quality</strong>.<strong>Power</strong> circuit<strong>Power</strong> supply (*) (**)230 VacVoltage tolerance - 15 % / + 15 %Frequency50 - 60 HzConsumption3 V·A(*) The power supply voltage is taken during the measurement(**) Other voltages, on demandCurrent measurement circuitWith current sensing clip:20 ... 2 000 Aac (scale 2 000 A)CP-2000-2002 ... 200 Aac (scale 2 000 A)CPR-1000CPR-500CP-200 (M1-U)CP-100 (M1-U)CP-5C-FLEX 2000/200-45C-FLEX 2000/200-80C-FLEX 10 k / 1 K - 120Measurement accuracy (+5 ºC ... / +45 ºC)VoltageCurrent<strong>Power</strong> ratingsError in current sensing clips is not includedData memoryRecording capacityRecording periodSoftware: Program to configure the readingand presentation of data in an environment10 ... 1 000 Aac5 ... 500 Aac2 ... 200 Aac1 ... 100 Aac50 mA ... 5 Aac200 ... 2,000 Aac200 ... 2,000 Aac1 000 ... 10 000 A c.a.0.5 % of the reading0.5 % of the reading1 % of the reading1 MBProgrammable<strong>Power</strong>VisionAmbient conditionsLimit temperature 0 ºC ... +50 ºCRelative humidityMaximum 85 % without condensationStandardsEN-61010 cat. III (Safety), IEC-60664, VDE-0110, UL-94, EN-50081-1, EN-50082, EN-61000-4-15Q2-19


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>CAVASingle-phase power <strong>quality</strong> <strong>analyzers</strong>DimensionsReferencesRMS voltageRMS currentActive, reactive andapparent powerFPFrequencyWeighted RMSFlicker: WAFlicker: PstHarmonics: THDGaps (Numberof cycles)Micro-drops(Number of cycles)Classification ofintervals of U% correct cyclesCommunicationsTypeCode• • • • • • • • • RS-232 CAVA-251 Q20112• • • • • • • • • • RS-232 CAVA-252 Q20122• • • • • • • • • • • • RS-232 CAVA-253 Q20132Distribution of memoryType of file Default storage capacity Data stored*.STD 74 days Voltage, current, power, FP, flicker, harmonics, ...*.EVQ minimum of 342 events Measurement events (overvoltages, voltage gaps and interruptions)*.EVE 4655 records Events related to the analyzer (change of setup, change of hour, etc.)Q2-20


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>Relation between products and accessoriesConverters Transformers Clips SoftwareCommunications converters Measurement transformers Current sensing clips Energy management softwareSee M.5 See M.7 See M.8 See M.9QNA500• • -- •QNA -413• • -- •QNA -412• • -- •QNA-P-- -- • •QNA-PT-- • -- •CAVA-- -- • •Q2-21


Q2-22<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>Q2-23


<strong>Power</strong> <strong>quality</strong> <strong>analyzers</strong>+ information: central@circutor.eswww.circutor.comDesigned by: dpt. Communication - CIRCUTOR, SACIRCUTOR, SA - Vial Sant Jordi, s/n08232 Viladecavalls (Barcelona) SpainTel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14central@circutor.esCIRCUTOR, SA reserves the right to change any information contained in this catalogue