10.07.2015 Views

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical DataAuxiliary contacts8/59http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008NHI…PKZNHI11(S)-PKZ2 NHI22(S)-PKZ2 NHI2-11S-PKZ2 AGM2-11-PKZ2Auxiliary contactsRated impulse withstand voltage U imp V AC 6000 6000 6000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3Rated operational voltage U e V AC 500 500 500 500Rated operational currentAC–15 230 – 240 V I e A 6 6 6 5400 – 415 V I e A 3 1.5 3 3440 V I e A 1.5 1.5 1.5 1.5500 V I e A 1.5 1.5 1.5 1.5Lifespan, mechanical Operations x 10 6 0.1 0.1 5 0.01Lifespan, electrical Operations x 10 6 0.05 0.05 1 0.005PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerControl <strong>circuit</strong> reliability (at U e = 24 V DC, U min =17 V, I min = 10 mA)Failure rate l Control <strong>circuit</strong> reliability through the entire mechanical lifespanInterlocked opposing contacts to ZH 1/457 – – Yes YesShort-<strong>circuit</strong> rating without weldingFuseless240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6Fuse A gG/gL 10 10 10 10Terminal capacitiesSolid or flexible conductorwith ferrulemm 2 1 x (0.75 – 2.5)2 x (0.75 – 2.5)Solid or stranded AWG 1 x (22 – 14)2 x (22 – 14)Safe isolation to VDE 0106 Part 101 and Part 101/A11 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (22 – 14)2 x (22 – 14)Between auxiliary contacts and main contacts V AC 690 690 5001 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (22 – 14)2 x (22 – 14)240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,61 x (0.75 – 2.5)2 x (0.75 – 2.5)22 – 14HI...-S-PKZ2 HI11-S/EZ-PKZ2 ZMR-...(95 – 96) ZMR-...(97 – 98)Auxiliary contactsRated impulse withstand voltage U imp V AC 6000 6000 6000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3Rated operational voltage U e V AC 500 500 500 500Rated operational currentAC–15 230 – 240 V I e A 6 6 1.5 1.5400 – 415 V I e A 1.5 3 0.7 0.5440 V I e A 1.5 1.5 0.5 0.3500 V I e A 1.5 1.5 0.5 0.3Lifespan, mechanical Operations x 10 6 5 5 0.01 0.01Lifespan, electrical Operations x 10 6 1 1 0.005 0.005Control <strong>circuit</strong> reliability (at U e = 24 V DC, U min =17 V, I min = 10 mA)Failure rate l Control <strong>circuit</strong> reliability through the entire mechanical lifespanInterlocked opposing contacts to ZH 1/457 – – – –Short-<strong>circuit</strong> rating without weldingFuseless240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6– –Fuse A gG/gL 10 10 10 10Terminal capacitiesSolid or flexible conductor withferrulemm 2 1 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (0.75 – 2.5)2 x (0.75 – 2.5)Solid or stranded AWG 22 – 14 22 – 14 22 – 14 22 – 14Safe isolation to VDE 0106 Part 101 and Part 101/A1Between auxiliary contacts and main contacts V AC 500 500 – –1 x (0.75 – 2.5)2 x (0.75 – 2.5)For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!