10.07.2015 Views

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/56Technical DataAuxiliary contacts, voltage releasesNHI…PKZ, AGM, U-PKZ, A-PKZ,<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4NHI...PKZ0 NHI-E-...PKZ0 VHI...PKZ0 AGM tripindicationAuxiliary contactsRated impulse withstand voltage U imp V AC 6000 4000 4000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3Rated operational voltage U e V AC 500 440 440 500U e V DC 250 250 250 250Safe isolation to VDE 0106 Part 101 and Part 101/A1Between auxiliary contacts and main contacts V AC 690 690 690 690Rated operational currentAC–15220 – 240 V I e A 3.5 1 1 3.5380 – 415 V I e A 2 – – 2440 – 500 V I e A 1 – – 1DC-13 L/R – 100 ms24 V I e A 2 2 2 260 V I e A 1.5 – – 1.5110 V I e A 1 – – 1220 V I e A 0.25 – – 0.25LifespanLifespan, mechanical Operations x 10 6 0.1 0.1 0.1 0.01Lifespan, electrical Operations x 10 6 0.05 0.1 0.1 0.005Control <strong>circuit</strong> reliability (at U e = 24 V DC, U min = 17 V, I Failure rate l < 10 -8 < 1 failure at 1 x 10 8 operationsmin= 5.4 mA)Interlocked opposing contacts to ZH 1/457 Yes – – –Short-<strong>circuit</strong> rating without weldingFuseless FAZ-B4/1-HI – – FAZ-B4/1-HIFuse A gG/gL 10 10 10 10Terminal capacitiesSolid or flexible conductor with ferrule mm 2 0.75 – 2.5 0.75 – 1.5 0.75 – 1.5 0.75 – 2.5Solid or stranded AWG 18 – 14 18 – 16 18 – 16 18 – 14Undervoltage releaseTerminal capacitiesU-PKZ...Solid or flexible conductor withmm 2 2 x (0.75 – 2.5)ferruleSolid or stranded AWG 2 x (18 – 14)Main conducting pathsRated operating voltage U e V AC 42 – 480Rated operating voltage U e V DC 24 – 250Pick-up voltage x U s 0.85 – 1.1Drop-out voltage x U s 0.7 – 0.35Power consumption Pick-up AC Pick-up VA 5Sealing AC Sealing VA 3Shunt releaseTerminal capacitiesA-PKZ...Solid or flexible conductor withmm 2 2 x (0.75 – 2.5)ferruleSolid or stranded AWG 2 x (18 – 14)Main conducting pathsRated operating voltage U e V AC 42 – 480Rated operating voltage U e V DC 24 – 250Operating range AC x U s 0.7…1.1DC x U s 0.7…1.1Power consumptionAC Pick-up AC Pick-up VA 5Sealing AC Sealing VA 3DC Pick-up DC Pick-up W 3Sealing DC Sealing W 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!