10.07.2015 Views

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker switching capacity and (high-capacity) compact starterEngineeringSwitching capacityRated uninterrupted current I uRated conditional short-<strong>circuit</strong> current I q IEC/EN 60 947-4-1Rated ultimate short-<strong>circuit</strong> breaking capacity I cu ⎫IEC/EN 60 947-2Rated service short-<strong>circuit</strong> breaking capacity I⎬cs ⎭1) 1) 1) 1) 1)230 V 400 V 440 V 500 V 690 VIu I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I csA kA kA kA A kA kA kA A kA kA kA A kA kA kA A kA kA kA APKZ2/ZM with classification type “1” and “2”0,16 – 1,6 N N N N N2,4 N N N N N4 N N N N 4,5 4,5 2,5 636 N N N N 4,5 4,5 2,5 8010 30 N 30 N 10 10 5 80 7 7 3,5 80 4,5 4,5 2,5 8016 30 N 30 N 10 10 5 100 7 7 3,5 100 4,5 4,5 2,5 10025 30 30 7,5 160 30 30 7,5 160 10 10 5 125 7 7 3,5 125 4,5 4,5 2,5 12532 30 30 7,5 160 30 30 7,5 160 10 10 5 160 7 7 3,5 160 4,5 4,5 2,5 16040 30 30 7,5 160 30 30 7,5 160 10 10 5 160 7 7 3,5 160 4,5 4,5 2,5 160PKZ2/ZM + CL-PKZ2 with classification type “1” and “2”0,16 – 1,6 N N N N N2,4 N N N N N4 N N N N 10 4,5 2,5 N6 N N N N 10 4,5 2,5 N10 30 N 30 N 5 N 3,5 N 10 4,5 2,5 N16 30 N 30 N 5 N 3,5 N 10 4,5 2,5 N25 7,5 N 7,5 N 5 N 3,5 N 10 4,5 2,5 N32 7,5 N 7,5 N 5 N 3,5 N 10 4,5 2,5 N40 7,5 N 7,5 N 5 N 3,5 N 10 4,5 2,5 NPKZ2/ZM(R)-.../SE1A(-G)... with classification type “1”0,16 – 1,6 N N N N N N N N N N N N N N N2,4 N N N N N N N N N N N N N N N4 N N N N N N N N N N N N 4,5 N N 636 N N N N N N N N N N N N 4,5 N N 8010 N N N N N N 10 N N 80 7 N N 80 4,5 N N 8016 N N N N N N 10 N N 100 7 N N 100 4,5 N N 10025 30 N N 160 30 N N 160 10 N N 125 7 N N 125 4,5 N N 12532 30 N N 160 30 N N 160 10 N N 160 7 N N 160 4,5 N N 16040 30 N N 160 30 N N 160 10 N N 160 7 N N 160 4,5 N N 160PKZ2/ZM-.../S(-G) with classification type “1” and “2”0,6 – 2,4 N N N N N N N N N N4 – 6 N N N N N N N N 10 N N 8010 – 16 N N N N N N N N 10 N N 10025 – 40 N N N N N N N N 10 N N 160PKZ2/ZM-..-8 and PKZ2/ZM-..-8/SE1A(-G)0,16 – 1,6 N N N N N N N N N N2,4 N N N N N N N N N N4 N N N N N N N N N 4,5 2,5 636 N N N N N N N N N 4,5 2,5 8010 N 30 N N 30 N N 10 5 80 N 7 3,5 80 N 4,5 2,5 8016 N 30 N N 30 N N 10 5 100 N 7 3,5 100 N 4,5 2,5 10025 N 30 7,5 160 N 30 7,5 160 N 10 5 125 N 7 3,5 125 N 4,5 2,5 12532 N 30 7,5 160 N 30 7,5 160 N 10 5 160 N 7 3,5 160 N 4,5 2,5 16040 N 30 7,5 160 N 30 7,5 160 N 10 5 160 N 7 3,5 160 N 4,5 2,5 160PKZ2/ZM-...-8/S(-G)0,6 – 2,4 N N N N N N N N N N4 – 6 N N N N N N N N N 10 5 8010 – 16 N N N N N N N N N 10 5 10025 – 40 N N N N N N N N N 10 5 160PK228/53PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerNotesNo upstream <strong>protective</strong> devicerequired,as it is the autoprotectedrange (100 kA)1) Fuse (A gG/gL) for enhancing the switchingcapacity of the motor-<strong>protective</strong> <strong>circuit</strong>-breakerto 100 kANNot necessary

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!