10.07.2015 Views

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008Circuit-breaker switching capacity from serial no. 04EngineeringSwitching capacityPKZM08/49Rated uninterrupted current I uRated conditional short-<strong>circuit</strong> current I q IEC/EN 60947-4-1Rated ultimate short-<strong>circuit</strong> breaking capacity I cu ⎫⎬ IEC/EN 60947-2Rated service short-<strong>circuit</strong> breaking capacity I cs ⎭230 V 400 V 440 V 500 V 690 VIu I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I csA kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1)PKZM0, PKZM0...-T, PKM0 with classification type “1” and “2”0,16 – 1 150 150 150 N 150 150 150 N N N N1,6 150 150 150 N 150 150 150 N N N N2,5 150 150 150 N 150 150 150 N N N 5 5 5 504 150 150 150 N 150 150 150 N N N 3 3 3 506,3 150 150 150 N 150 150 150 N N 42 42 6 50 3 3 2 5010 150 150 150 N 150 150 150 N 42 42 10 50 42 42 6 50 3 3 2 5012 50 50 10 50 50 50 10 50 15 15 10 50 15 15 6 50 3 3 2 5016 50 50 10 50 50 50 10 50 15 15 10 50 15 15 6 50 3 3 2 5020 50 50 10 50 50 50 10 50 10 10 10 50 6 6 6 50 3 3 2 5025 50 50 10 50 50 50 10 50 10 10 10 50 6 6 6 50 3 3 2 5032 50 50 10 50 50 50 10 50 10 10 10 50 6 6 6 50 3 3 2 50PKZM01, PKZM0, PKZM4motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM0 (PKZM0...-T, PKM0) + CL-PKZ00,16 – 1 N N N N 20 N1,6 N N N N 20 N2,5 N N N N 20 20 20 N4 N N N N 20 20 20 N6,3 N N N 50 N 20 20 20 N10 N N N 20 N 20 20 20 N12 N N N 20 N 5 5 2,5 N16 N N N 20 N 5 5 2,5 N20 N N N 10 10 10 N 5 5 2,5 N25 N N N 10 10 10 N 5 5 2,5 N32 N N N 10 10 10 N 5 5 2,5 NPKZM0 (PKZM0...-T, PKM0) + 2 CL-PKZ00,16 – 1 N N N N 20 N1,6 N N N N 20 N2,5 N N N N 40 40 20 N4 N N N N 40 40 20 N6,3 N N N 50 N 20 20 20 N10 N N N 40 N 20 20 20 N12 N N N 40 N 10 10 2,5 N16 N N N 40 N 10 10 2,5 N20 N N N 20 20 20 N 10 10 2,5 N25 N N N 20 20 20 N 10 10 2,5 N32 N N N 20 20 20 N 10 10 2,5 NNotesNo upstream <strong>protective</strong> devicerequired, as it is the autoprotectedrange (100/150 kA)1) Necessary back-up fuse when the short-<strong>circuit</strong> currentexceeds the rated conditional short-<strong>circuit</strong> current of the device (I cc I q ).NNot required

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!