10.07.2015 Views

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/38OrderingRemote operatorsOrderingRemote operators8/39PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerRE-PKZ2 remote operatorActuation via auxiliary contactRE-PKZ, RS-PKZ<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netContact sequence Circuit diagram for pulsed operation Part no.Article no.OFF and RESET separate OFF equals RESETRS-PKZ2 remote operatorActuation from PLC semi-conductor outputsLI >TLI >T7274A20 A40 B2072 74A20 A30 A0IL(+)N(-)72 74LINECONTROLA20 A40 B20OON OFF RESET3334IL(+)N(-)72 74LINECONTROLA20 A40 B20OON OFF RESET3334Power and control sections have the same potential.Can be actuated by a single pulse (f 2 VA/W, 15 ms)or by maintained contact. When activated, the powersection is energized directly from the mains supply(700 VA/W, 30 ms). Control section can be activatedby: NHI, AGM, ETS4-VS3, EK..., PLC with isolatedcontacts without RC suppressor.http://catalog.moeller.netRE-PKZ2(220-240V50/60HZ,DC)063676RE-PKZ2(110-120V50/60HZ,DC)063673RE-PKZ2(24V50/60HZ,DC)063670– L(+)N(-)RS-PKZ2(220-240V50/60HZ,DC)063688ONPower and control sections electrically isolated fromone another. Control section always 24 V. Safeisolation between power and control section isassured. Can be actuated by a single pulse (f 2 VA/W, 15 ms) or by maintained contact. The controlsection can be activated directly from the PLCelectronic outputs (24 V DC). When activated, thepower section is energized directly from the mainssupply (700 VA/W, 30 ms).RS-PKZ2(380-415V50/60HZ)063689– RS-PKZ2(24V50/60HZ,DC)CONTROL34063682ION72 74A20 A30 A0L(+)LINECONTROLOFF/RESETN(-)72 74LINEA20 A30 A0OOFF/RESET333424V DC3324V DCAC/DC<strong>Moeller</strong> HPL0211-2007/2008Pricesee pricelistStd. pack1 off Can be fitted to <strong>circuit</strong>-breakerand (high-capacity) compact1 off starter. Remote On/Off switchingof <strong>circuit</strong>-breaker and trip reset toOFF.1 off Remote operator can be switchedoff locally and the thumb-griplocked using 6 mm padlock.Suitable for use with AC or DC.Can be combined with U, U-HI20,UVHI-PKZ2 voltage releases or A-PKZ2.NHI standard auxiliary contact isalways required in addition forcombination of <strong>circuit</strong>-breaker1 off and RE/RS-PKZ2 remote operator.Cannot be used in conjunction1 offwith (R)H-PKZ2 door-couplinghandle.Mounting is possible in On andOff switch positions.Internal electronic interlockingalways makes “Off” a priority.A green background to the slideindicates the q “Hand” positiomwith contacts (33/34) open.A red background to the slideindicates the q “Auto” position1 off with contacts (33/34) closed.In the Hand’’ position, remoteswitching is not possible.Notes53Accessories1Page1 <strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker, <strong>circuit</strong>-<strong>breakers</strong> a 8/273 Standard auxiliary contact a 8/355 Trip-indicating auxiliary contact a 8/35Additional accessories a 8/33542RE-PKZ, RS-PKZ9AccessoriesPage2 (high-capacity) compact starters a 8/294 Standard auxiliary contact a 8/355 Trip-indicating auxiliary contact a 8/359 Clip plate a 8/44PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerMinimum command time:ONCONTROLIONOf 15t (ms)OFF/RESETCONTROLIOFF/RESETOf 15t (ms)LINEf 300IONCONTROLOOFFMain contactF 30 F 30t (ms)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!