Motor-protective circuit-breakers - Moeller Electric Parts
Motor-protective circuit-breakers - Moeller Electric Parts
Motor-protective circuit-breakers - Moeller Electric Parts
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker8/28OrderingCompact starters, high-capacity compact starters<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netMax. motor ratingRateduninterruptedcurrentSetting rangeAC-3 Overload releases Short-<strong>circuit</strong>releases220 V230 V240 V380 V400 V415 V440 V 500 V 660 V690 VP P P P P I u A AkW kW kW kW kW AI rI rmhttp://catalog.moeller.netCompact starters, Type 1“ coordination0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 PKZ2/ZM-1/SE1A/11(230V50HZ,240V600633640.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 PKZ2/ZM-1,6/SE1A/11(230V50HZ,240V0633720.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 PKZ2/ZM-2,4/SE1A/11(230V50HZ,240V0633820.75 1.5 1.5 2.2 3 4 2.4…4 35…55 PKZ2/ZM-4/SE1A/11(230V50HZ,240V600633921.1 2.2 3 3 4 6 4…6 50…80 PKZ2/ZM-6/SE1A/11(230V50HZ,240V600634022.2 4 4 5.5 7.5 10 6…10 80…140 PKZ2/ZM-10/SE1A/11(230V50HZ,240V6063412L4 7.5 9 9 12.5 16 10…16 130…220 PKZ2/ZM-16/SE1A/11(230V50HZ,240V6063422Ι >5.5 12.5 12.5 15 22 25 16…25 200…350 PKZ2/ZM-25/SE1A/11(230V50HZ,240V6063432A1 13 217.5 15 17.5 22 22 32 24…32 275…425 PKZ2/ZM-32/SE1A/11(230V50HZ,240V6063442A2 14 2211 18.5 22 24 30 36 32…40 350…500 PKZ2/ZM-40/SE1A/11(230V50HZ,240V6T063452High-capacity compact starters, Type 2“ coordination0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 PKZ2/ZM-1/S(230V50HZ,240V60HZ)0634720.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 PKZ2/ZM-1,6/S(230V50HZ,240V60HZ)0634820.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 PKZ2/ZM-2,4/S(230V50HZ,240V60HZ)0634920.75 1.5 1.5 2.2 3 4 2.4…4 35…55 PKZ2/ZM-4/S(230V50HZ,240V60HZ)0635021.1 2.2 3 3 4 6 4…6 50…80 PKZ2/ZM-6/S(230V50HZ,240V60HZ)0635122.2 4 4 5.5 7.5 10 6…10 80…140 PKZ2/ZM-10/S(230V50HZ,240V60HZ)063522L4 7.5 9 9 12.5 16 10…16 130…220 PKZ2/ZM-16/S(230V50HZ,240V60HZ)0635325.5 12.5 12.5 15 22 25 16…25 200…350 PKZ2/ZM-25/S(230V50HZ,240V60HZ)I >063542A1 13 217.5 15 17.5 22 22 32 24…32 275…425 PKZ2/ZM-32/S(230V50HZ,240V60HZ)06355222 A2 14I >>11 18.5 22 24 30 36 32…40 350…500 PKZ2/ZM-40/S(230V50HZ,240V60HZ)063562TPKZ2/ZMPart no.Article no.<strong>Moeller</strong> HPL0211-2007/2008Pricesee pricelistOrderingCompact starters, high-capacity compact startersStd. pack Notes Notes1 off 1 M/1 B auxiliarycontact built intothe contact module1 off Rated short-<strong>circuit</strong>currentI q = 100 kA/400 VHigh-capacitycontact module hasbuilt-in auxiliarycontacts: 1 M/1 B53 4AccessoriesPage3 Standard auxiliary contact a 8/354 Standard auxiliary contact a 8/355 Trip-indicating auxiliary contact a 8/356 Shunt release, undervoltage release a 8/377 Remote operators a 8/399 Clip plate a 8/44Other accessories a 8/33Further actuating voltages a 8/45Manual a 8/44Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102Supplied fitted to C-PKZ2 clip plate, can be snap fitted to one or two IEC/EN 60715 top-hat rails, height 15 mmOverload release, adjustable I r = 0.6 – 1.0 x I uAdjustable short-<strong>circuit</strong> release I rm = 8.5 – 14 x I u setex-works to 12 x I uPTB 02 ATEX 3152Observe manual.9PKZ2/ZM768/29PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker