10.07.2015 Views

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

Motor-protective circuit-breakers - Moeller Electric Parts

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/14OrderingInsulated enclosuresCI-PKZ<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Insulated enclosures for surface mountingFor PKZM01 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>ProtectiontypeIP40For use withPKZM01+NHI-E orVHI-PKZ01+U or A orNHI+L (2 off)Part no.Article no.CI-PKZ01281403With actuation membrane IP65 CI-PKZ01-G281404Pricesee pricelistStd. pack1 off Integrated terminal for PE(N)connection, two M25 cable entryknockouts at top and at bottom.Lockable in off positionLockable in off position incombination with VHI-PKZ01With emergency-stop pushbutton actuator, stay-putPKZM01+NHI-E or+U or A (undervoltageor shunt release)+L (2 off)CI-PKZ01-SVB281405CI-PKZ01-SVB-V281944CI-PKZ01-PVT2814061 off1 offWith emergency-stop pushbutton actuator, releasewith keyCI-PKZ01-PVS281407For extension of CI/E-PKZ01-X... unitas unit PKZM01 CI-PKZ01-X2899341 off Integrated terminal for PE(N)connection, two M25 cable entryknockouts at top and at bottom.For PKZM0 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Cover with aperturedimensioned toaccommodate front ofbreaker. IP40, whenmounted turned throughWith black/grey rotaryhandleWith red/yellow rotaryhandle for use asemergency-stop switches toIEC/EN 60204IP41whenmountedverticallyIP65PKZM0-...+NHI or AGM+U or A (undervoltageor shunt release)+NHI-E+L-PKZ0 (2 off)CI-K2-PKZ0219653CI-K2-PKZ0-G219654CI-K2-PKZ0-GR2196551 off M25 metric cable entry knockout,top and bottomPush-through cable entrydiaphragm top, bottom, in theback plate and for control cableentry.CI-K2 insulated enclosureincludes N and PE terminal.Cover with aperturedimensioned toaccommodate front ofbreakerIP40PKZM0-...+NHI or U or A+L-PKZ0 (2 off)CI-PKZ0-M267083Integrated terminal for PE(N)connection, two M25 cable entryknockouts at top and at bottom.With black/grey rotaryhandleWith red/yellow rotaryhandle for use asemergency-stop switches toIEC/EN 60204IP55PKZM0-...+NHI-E+NHI or U or A+L-PKZ0 (2 off)For PKZM0 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> with early-make VHI auxiliary contactsWith black/grey rotary IP65handleWith red/yellow rotaryhandle for use asemergency-stop switches toIEC/EN 60204With black/grey rotaryhandleWith red/yellow rotaryhandle for use asemergency-stop switches toIEC/EN 60204IP55+NHI or AGM+U or A+L-PKZ0 (2 off)PKZM0-... and VHI+U or A (undervoltageor shunt release)+L-PKZ0 (2 off)CI-PKZ0-GM260089CI-PKZ0-GRM260104CI-K2-PKZ0-GV219657CI-K2-PKZ0-GRV219656CI-PKZ0-GVM263526CI-PKZ0-GRVM2635251 off1 off M25 metric cable entry knockout,top and bottomPush-through cable entrydiaphragm top, bottom, in theback plate and for control cableentry.CI-K2 insulated enclosureincludes N and PE terminal.1 off Integrated terminal for PE(N)connection, two M25 cable entryknockouts at top and at bottom.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!