<strong>Moeller</strong> HPL0211-2007/2008Contents8/1<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Short down times of machines and systemsrequire a fast re-availability of the system. Withthe PKZ, fuseless short-<strong>circuit</strong> protection andoverload protection is provided in one device.<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> PKZM01, PKZM0, PKZM4PageSystem overview 8/2Ordering<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 8/3<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> for starter combinations 8/6<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> PKZ2PageSystem overview 8/25Ordering<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 8/26Circuit-<strong>breakers</strong> 8/26<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Transformer-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 8/6Compact starter, high-capacity compact starter 8/28Auxiliary contact 8/8<strong>Motor</strong> protection modules 8/30Auxiliary contacts, voltage releases 8/10Components for system protection 8/32<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM0 to 32 Aand PKZM4 to 65 A- Simple engineering as most have 50kA short-<strong>circuit</strong> rating- trip-indication enables remotediagnostics- Higher safety by use as main-switchor repair and maintenance switchPage 8/4<strong>Motor</strong>-<strong>protective</strong><strong>circuit</strong>-breaker PKZM01pushbutton operation ofmotor-<strong>protective</strong> <strong>circuit</strong><strong>breakers</strong>in enclosure- IP40 and IP65 offer solutions for allenvironmental conditions- Integrated Emergency-stoppushbutton reduces wiringPages 8/3 and 8/14<strong>Motor</strong>-<strong>protective</strong><strong>circuit</strong>-breaker PKZ2<strong>Motor</strong> protection and system<strong>protective</strong> switch up to 40 A- Higher flexibility due to plug-in tripblocks- Remote operator enables switchingfrom central desk- High power switch-block for heavyswitching conditions- ATEX approval for the protection ofEEx e motors up to 40 APage 8/2EngineeringAccessories for motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> in enclosures 8/12OrderingInsulated enclosure 8/14Accessories 8/17Busbar adapter 8/19Wiring sets 8/21Three-phase commoning links 8/22Actuating voltages 8/24Engineering<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 8/47Characteristic curves 8/48Switching capacity 8/49Technical data<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 8/54Auxiliary contact 8/56Dimensions<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> PKZM01, PKZM0 8/62Accessories 8/62<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> PKZM4 8/67Insulated enclosures 8/33Auxiliary contacts 8/34Current limiter 8/35Voltage releases 8/36Remote operators 8/38Contact modules 8/40Accessories for contact modules 8/42Accessories 8/44Actuating voltages 8/45Engineering<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 8/47Characteristic curves 8/51Switching capacity 8/53Technical data<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 8/57(High-capacity) contact module 8/58Current limiter 8/58Auxiliary contacts 8/59Voltage releases 8/60Remote operators 8/61DimensionsAccessories 8/67<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 8/69Accessories 8/69Tool-less plug connectionPlug-in wire jumpers for assemblyof motor starters- Plug-in wire jumpers save wiring time- Short mounting times as only a top-hat rail is necessary- Suitable design for high value systemsPage 8/2For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


Ordering<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>8/3http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008PKZM01Max. motor ratingRateduninterruptedcurrentSetting rangeAC-3 Overload releases Short-<strong>circuit</strong> releases220 V 380 V 440 V230 V240 V400 V415 VP P P I u I r I rmkW kW kW A A AScrew terminalsPart no.Article no.Pricesee pricelistRGStd. pack<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, Type "1" and Type "2" coordination– – – 0.16 0.1…0.16 2.2 PKZM01-0,16278475LI >T– 0.06 0.06 0.25 0.16…0.25 3.5 PKZM01-0,252784760.06 0.09 0.12 0.4 0.25…0.4 5.6 PKZM01-0,42784770.09 0.12 0.18 0.63 0.4…0.63 8.8 PKZM01-0,632784780.12 0.25 0.25 1 0.63…1 14 PKZM01-12784790.25 0.55 0.55 1.6 1…1.6 22 PKZM01-1,62784800.37 0.75 1.1 2.5 1.6…2.5 35 PKZM01-2,52784810.75 1.5 1.5 4 2.5…4 56 PKZM01-42784821.1 2.2 3 6.3 4…6.3 88 PKZM01-6,32784832.2 4 4 10 6.3…10 140 PKZM01-102784843 5.5 5.5 12 8…12 168 PKZM01-122784854 7.5 9 16 10…16 224 PKZM01-162833901 offNotes65 33AccessoriesPage3 Standard auxiliary contact a 8/85 Trip-indicating auxiliary contact a 8/116 Shunt release, undervoltage release a 8/11Single-phasing sensitivity according to IEC/EN 60947-4-1, VDE 0660 Part 102.Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm heightFor <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/8OrderingStandard auxiliary contactsOrderingStandard auxiliary contacts8/9<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Contacts Contact diagram Contact sequence For use withN/O =NormallyopenN/C =NormallyclosedStandard auxiliary contactsFor motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>1 N/O 1 N/C 1.13 1.21 ScrewL1L2L3terminalsNHI111.14 1.221 N/O 1 N/C 1.13 1.21 SpringloadedL1L2L3NHI11terminalsI >PKZM01PKZM0PKZM4PKZM0-TPKM0Order number forseparate ordersNHI11-PKZ0229680see pricelistStd. packAGM, NHI-E-... trip-indicating auxiliary contact15<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>I >1.14 1.221 N/O 2 N/C 1.13 1.21 1.31 ScrewL1L2L3terminals 072895NHI12I >2 N/O 1 N/CL1L2L31.14 1.22 1.321.13 1.21 1.33072894NHI21I >1.14 1.22 1.341 N/O 1 N/C 1.53 1.61NHI-E-11-PKZ0L1L2L3151 N/ONHI-E-11L1L2L3NHI-E-10I >1.54 1.621.53082884The 45 mm (PKZM0) or 55 mm (PKZM4) widths ofthe motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> remainunchanged.1 <strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 8/45 Trip-indicating auxiliary contact 8/11Additional accessories 8/17I >1.541 N/O 1.53 SpringloadedL1L2L3NHI-E-10terminals229681I >1 N/C 1.51 SpringloadedL1L2L3NHI-E-01terminals1.54229682I >1.52


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/10OrderingAuxiliary contacts, undervoltage releasesOrderingAuxiliary contacts, undervoltage releases8/11<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.nethttp://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>ContactsN/O = Normally openContact diagram Contact sequence For use with Part no.Order number forseparate ordersN/C = Normally closedTrip-indicating auxiliary contactsFor motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>2 x 1 N/O On/Off"+" "I >"PKZM04.43 4.13PKZM4L1L2L3"+""I >"PKZM0-TPKM0PKZM01Trip "+"L1L2L3"+""I >"2 x 1 N/C On/OffL1L2L3"+"4.31"I >"4.21PKZM0PKZM4PKZM0-T"+"PKM0"I >"PKZM01Trip "+"I >I >4.44 4.14AGM2-10-PKZ0072898AGM2-01-PKZ0072899Pricesee pricelistStd. pack2 off2 offCan be fitted to the right of motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>:Can be combined with:Standard auxiliary contactNHI11-PKZ0NHI12-PKZ0NHI21-PKZ0NHI-E-...Differential indication:a) General trip indication (overload)b) Short-<strong>circuit</strong> tripNotes13<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>L1L2L3"+""I >"4.32 4.22Local short-<strong>circuit</strong> indication by red indicator,manually resettable.Early-make auxiliary contactFor motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>2 N/O 3.13 3.23PKZM0PKZM0-TPKM0I >PKZM01VHI20-PKZ0203595VHI20-PKZ012784952 off Can be fitted to front on motor-<strong>protective</strong> <strong>circuit</strong>breaker,45 mm width of the motor-<strong>protective</strong><strong>circuit</strong>-breaker remains unchanged.For early energization of undervoltage release,5 off e.g. in emergency-stop <strong>circuit</strong>s to EN 60204.13AccessoriesPage1 <strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker a 8/43 Standard auxiliary contact a 8/83.14 3.24Shunt releasesScrew terminalsC1PKZM0PKZM4PKZM0-TPKM0PKZM01A-PKZ0(230V50HZ)073187A-PKZ0(24VDC)0732002 off Can be fitted to the left of:<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>2 off Cannot be combined with:U-PKZ0 undervoltage releaseDC: Intermittent operation 5 sUndervoltage releasesScrew terminalsSpring-loaded terminalsC2D1U >TPKZM0PKZM4CL-PKZ00828811 off Max. rated operational voltage U e = 690 V, rateduninterrupted current I u =63ACan be used for individual and group protectionFor group protection and in combination withPKZM4, order additional BK25/3 incomingterminal if required.Mounting next to or behind the motor-<strong>protective</strong><strong>circuit</strong>-breaker.PKZM4: 16 – 63 A: 100 kA/400 VPKZM4: 16 – 63 A: 10 kA/690 V


8/12EngineeringAccessories for motor-<strong>protective</strong> <strong>circuit</strong>-breaker in enclosurePKZM01, PKZM0EnclosuresAccessories<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Part no. Part no. DegreeofprotectSurface mounting enclosuresHandlecolourNHI..-PKZ0AGM2-..-PKZ0NHI-E..-PKZ0VHI..-PKZ0VHI..-PKZ01U-PKZ0orA-PKZ0<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker PKZM01CI-PKZ01 IP40 – – – ● – – ● ●– – – – ● ● ●● – ● – – – ●● – – – ● – ●CI-PKZ01-G IP65 – – – ● – – ● ●– – – – ● ● ●● – ● – – – ●● – – – ● – ●CI-PKZ01-PVTCI-PKZ01-PVSIP65Redyellow– – ● – – ● ●– – – – ● ● ●L-PKZ0CI-PKZ01-SVB IP65 – – – ● – – ● ●CI-PKZ01-SVB-V IP65 – – – – – K 1) ● ●<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker PKZM0CI-K2-PKZ0 IP41 – ● – ● – – ● ●– ● ● – – ● ●CI-K2-PKZ0-G IP65 Black ● – ● – – ● ●– ● ● – – ● ●CI-K2-PKZ0-GR IP65 Redyellow● – ● – – ● ●– ● ● – – ● ●CI-PKZ0-M IP40 – ● – ● – – – ●– – ● – – ● ●CI-PKZ0-GM IP55 Black ● – ● – – – ●– – ● – – ● ●CI-PKZ0-GRM IP55 Redyellow● – ● – – – ●– – ● – – ● ●<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker PKZM0 +early-make auxiliary contact VHI-PKZ0CI-K2-PKZ0-GV IP65 Black ● – – ● – ● ●– ● – ● – ● ●CI-K2-PKZ0-GRV IP65 Redyellow● – – ● – ● ●– ● – ● – ● ●CI-K2-PKZ0-GVM IP55 Black ● – – ● – – ●– – – ● – ● ●CI-K2-PKZ0-GRVM IP55 Redyellow● – – ● – – ●– – – ● – ● ●NotesThe combination possibilities of <strong>circuit</strong>-<strong>breakers</strong> in an enclosure with accessory modules are identified by a ●1) always necessaryFor <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


EngineeringAccessories for motor-<strong>protective</strong> <strong>circuit</strong>-breaker in enclosures8/13http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008EnclosuresAccessoriesPKZM4, PKZM01, PKZM0Part no. Part no. DegreeofprotectSurface mounting enclosuresHandlecolourNHI..-PKZ0AGM2-..-PKZ0NHI-E..-PKZ0VHI..-PKZ0VHI..-PKZ01U-PKZ0orA-PKZ0<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker PKZM4CI-K4-PKZ4-G IP65 Black ● ● ● – – ● ●● ● – ● – ● ●● ● ● – – ● ●● ● – ● – ● ●L-PKZ0<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Installation enclosuremotor-<strong>protective</strong> <strong>circuit</strong>-breaker PKZM01E-PKZ01 IP40 – – – ● – – ● ●– – – – ● ● ●● – ● – – – ●● – – – ● – ●E-PKZ01-G IP65 – – – ● – – ● ●– – – – ● ● ●● – ● – – – ●● – – – ● – ●E-PKZ01-PVTE-PKZ01-PVSIP65CI-K4-PKZ4-GR IP65 RedyellowRedyellow– – ● – – ● ●– – – – ● ● ●E-PKZ01-SVB IP65 – – – ● – – ● ●E-PKZ01-SVB-V IP65 – – – – – K 1) ● ●<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker PKZM0E-PKZ0 IP40 – ● – – – – – ●– – – – – ● ●E-PKZ0-G IP55 Black ● – ● – – – ●– – ● – – ● ●E-PKZ01-GR IP55 Redyellow● – ● – – – ●– – ● – – ● ●NotesThe combination possibilities of <strong>circuit</strong>-<strong>breakers</strong> in an enclosure with accessory modules are identified by a ●1) always necessaryFor <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/14OrderingInsulated enclosuresCI-PKZ<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Insulated enclosures for surface mountingFor PKZM01 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>ProtectiontypeIP40For use withPKZM01+NHI-E orVHI-PKZ01+U or A orNHI+L (2 off)Part no.Article no.CI-PKZ01281403With actuation membrane IP65 CI-PKZ01-G281404Pricesee pricelistStd. pack1 off Integrated terminal for PE(N)connection, two M25 cable entryknockouts at top and at bottom.Lockable in off positionLockable in off position incombination with VHI-PKZ01With emergency-stop pushbutton actuator, stay-putPKZM01+NHI-E or+U or A (undervoltageor shunt release)+L (2 off)CI-PKZ01-SVB281405CI-PKZ01-SVB-V281944CI-PKZ01-PVT2814061 off1 offWith emergency-stop pushbutton actuator, releasewith keyCI-PKZ01-PVS281407For extension of CI/E-PKZ01-X... unitas unit PKZM01 CI-PKZ01-X2899341 off Integrated terminal for PE(N)connection, two M25 cable entryknockouts at top and at bottom.For PKZM0 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Cover with aperturedimensioned toaccommodate front ofbreaker. IP40, whenmounted turned throughWith black/grey rotaryhandleWith red/yellow rotaryhandle for use asemergency-stop switches toIEC/EN 60204IP41whenmountedverticallyIP65PKZM0-...+NHI or AGM+U or A (undervoltageor shunt release)+NHI-E+L-PKZ0 (2 off)CI-K2-PKZ0219653CI-K2-PKZ0-G219654CI-K2-PKZ0-GR2196551 off M25 metric cable entry knockout,top and bottomPush-through cable entrydiaphragm top, bottom, in theback plate and for control cableentry.CI-K2 insulated enclosureincludes N and PE terminal.Cover with aperturedimensioned toaccommodate front ofbreakerIP40PKZM0-...+NHI or U or A+L-PKZ0 (2 off)CI-PKZ0-M267083Integrated terminal for PE(N)connection, two M25 cable entryknockouts at top and at bottom.With black/grey rotaryhandleWith red/yellow rotaryhandle for use asemergency-stop switches toIEC/EN 60204IP55PKZM0-...+NHI-E+NHI or U or A+L-PKZ0 (2 off)For PKZM0 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> with early-make VHI auxiliary contactsWith black/grey rotary IP65handleWith red/yellow rotaryhandle for use asemergency-stop switches toIEC/EN 60204With black/grey rotaryhandleWith red/yellow rotaryhandle for use asemergency-stop switches toIEC/EN 60204IP55+NHI or AGM+U or A+L-PKZ0 (2 off)PKZM0-... and VHI+U or A (undervoltageor shunt release)+L-PKZ0 (2 off)CI-PKZ0-GM260089CI-PKZ0-GRM260104CI-K2-PKZ0-GV219657CI-K2-PKZ0-GRV219656CI-PKZ0-GVM263526CI-PKZ0-GRVM2635251 off1 off M25 metric cable entry knockout,top and bottomPush-through cable entrydiaphragm top, bottom, in theback plate and for control cableentry.CI-K2 insulated enclosureincludes N and PE terminal.1 off Integrated terminal for PE(N)connection, two M25 cable entryknockouts at top and at bottom.


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616OrderingInsulated enclosures8/15http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008E-PKZProtectiontypeFor PKZM4 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>With black/grey rotary IP65handleWith red/yellow rotary IP65handle for use asEmergency-Stop switches toIEC/EN 60204For use with+VHI or NHI-E+NHI or AGM+U or A+L-PKZ0 (2 off)Part no.Article no.CI-K4-PKZ4-G225524CI-K4-PKZ4-GR225525Pricesee pricelistStd. pack1 off Metric knockout:top and bottom: M25/M321 off in the back plate: M25/M32Control cable entry: M20CI-K4 insulated enclosureincluding insulated PE terminal<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Insulated enclosures for flush mountingFor PKZM01 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Front IP40PKZM01+ NHI or U or A+NHI-E or VHI+L (2 off)E-PKZ012816331 off Integrated terminal for PE(N)connection.With actuation membrane Front IP65 E-PKZ01-G281634Lockable in off positionPKZM01+U or A+L (2 off)E-PKZ01-SVB281635Lockable in off position incombination with VHI-PKZ01With Emergency-Stop pushbutton actuator, stay-putWith Emergency-Stop pushbutton actuator, releasewith keyFor extension of CI/E-PKZ01-X... unitsPKZM01+U or A+NHI-E or VHI+L (2 off)PKZM01+NHI-E or VHI-PKZ01+U or A+L (2 off)E-PKZ01-SVB-V281943E-PKZ01-PVT281636E-PKZ01-PVS281637as unit PKZM01 E-PKZ01-X289935For PKZM0 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Cover with aperturedimensioned toaccommodate front ofbreakerFront IP40PKZM0-... +NHI or Uor A +L-PKZ0 (2 off)E-PKZ00729061 off Integrated terminal for PE(N)connection.With black/grey rotaryhandleWith red-yellow rotaryknob, for use asEMERGENCY STOP switch inaccordance with EN 60204Front IP55PKZM0-...+NHI or U or A+NHI-E+L-PKZ0 (2 off)E-PKZ0-G072907E-PKZ0-GR072908


8/16OrderingInsulated enclosuresSVB-PKZ, CL/EPKZ01<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4ProtectiontypeFor use withInsulated enclosures for surface mountingPadlocking featureFor up to 3 padlocks with 3 – 6 mm hasp thickness, for use as main switch to IEC/EN 60204Lockable in the 0-position of thePKZM0 or PKZM4 motor-<strong>protective</strong><strong>circuit</strong>-breaker.CI-K2-PKZ0-G(R)(V)CI-PKZ0-G(R)(V)MCI-K4-PKZ4-G(R)E-PKZ0-G(R)Part no.Article no.SVB-PKZ0-CI035129SVB-PKZ4-CI225526SVB-PKZ0-E035127Pricesee pricelistStd. pack3 off1 off3 offNeutral terminalFor connection of a 5th conductorFlexible, 1 – 4 mmB CI-K2-PKZ0-... K-CI-K1/220745120 off63 A, flexible, 6 – 16 mm 2 CI-K4-PKZ4-G(R) K25/109620010 offE-PKZ0(-G)(-GR)E-PKZ01(-G)Units for insulated enclosures for PKZ01Can be combined with CI-PKZ01-X and E-PKZ01-X.With operating membrane Front IP65 PKZM01+NHI-E or VHI-PKZ01+U or A orNHI+L (2 off)N-PKZ0082160CI/E-PKZ01-XG28993620 off1 offCan be locked in O position PKZM01+NHI-E+U or A+L (2 off) CI/E-PKZ01-XSVB289939Lockable in off position incombination with VHI-PKZ01With Emergency-Stop mushroomheadedpushbutton, stay-putWith EMERGENCY STOPmushroom-headed pushbutton,with key-releasePKZM01VHI-PKZ01+U or A+L (2 off)PKZM01+NHI-E or VHI-PKZ01+U or A+L(2 off)PKZM01+NHI-E or VHI-PKZ01+U or A+L(2 off)CI/E-PKZ01-XSVB-V289980CI/E-PKZ01-XPVT289937CI/E-PKZ01-XPVS289938For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


OrderingAccessories8/17http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008Cable entry Hole diameter External diameterof cablemmmmPart no.Article no.Metric cable glands to EN 50262• With lock nut and integral strain relief• IP68 up to 5 bar, halogen freeM20 20.5 6 – 13 V-M20206910M25 25.5 9 – 17 V-M25206911M32 32.5 13 – 21 V-M32206912M32 32.5 18 – 25 V-M32G226156Pricesee pricelistStd. pack20 off<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Metric diaphragm grommets•IP65• With integral push-through diaphragmM20 20.5 1 – 13 KT-M20207602100 offM25 25.5 1 – 18 KT-M25207603M32 32.5 1 – 24 KT-M32207604Colour For use with Part no.Article no.Pricesee pricelistStd. packNotesDoor coupling handle IP65Can be used with PKZM0 and PKZM4For use as main switch to IEC/EN 60204For use as a main switch withEmergency-Stop function, toEN 60204For use as a main switch to EN60204 in MCC powerdistribution systems and withPKZM0 installed whenrotated by 90°BlackRedyellowBlackPKZ0-XH106132PKZ0-XRH106133PKZ0-XH-MCC1061361 off Plug-in extension shaft A-H-PKZ0can be cut to desired length formounting depths of 100 – 240 mm.Carrier with extension shaftincluded in delivery.With ON/OFF switch position and“+” (tripped), lockableWith 3 padlocks, 4 – 8 mm hasp.Prepared for locking in ON.For use as a main switch withEmergency-Stop function toEN 60204 in MCC powerdistribution systems and withPKZM0 installed rotated by90°RedyellowPKZ0-XRH-MCC106137Terminal shroudFor enhancement of thedegree of protection of thePKZM4 to IP2xPKZM4HB-PKZ42565811 offFor <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


8/18OrderingAccessories<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Telescopic adaptersWith 45 mm top-hat rail to IEC/EN 60715, for compensating of the mountingdepth of rear mounted devices in CI-K.. enclosures and cabinets.Telescopic adapterPart no.Article no.M22-TA226161Pricesee pricelistStd. pack1 off Steplessly adjustable bymeans of a scale, from 75 –115 mm.Lockable rotary handleFor connection of the motor-<strong>protective</strong> <strong>circuit</strong>-breakerPKZM0 and PKZM4 as a main switch to EN 60204.Can be padlocked in the “0” position with a padlock.Hasp thickness: 3 – 6.35 mmAK-PKZ00308515 off Cannot be combined withVHI-PKZ0.Sealing facilityTo prevent tampering with the overload release and the testfunction, it can be sealed using industry standard sealingwireFor use with motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> PKZM0 andPKZM4PL-PKZ02035995 offDocumentationPKZM0 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, overloadmonitoring of EEx e motorsAWB1210-1458D/GB2661641 off German/EnglishPKZM4 motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, overloadmonitoring of EEx e motorsAWB1210-1457D/GB2661651 off German/EnglishBlade terminal to DIN 46244For connection of insulated ferrules for:main cables up to 25 A, 1 x 6.3 mm (DIN 46245)control <strong>circuit</strong> cables up to 6 A, 2 x 2.8 mm (DIN 46247)BT483059904100 off Use insulated ferrules to DIN46245.Colour Voltage Part no.Article no.VPricesee pricelistStd. packIndicator lights with neon bulbCI-K2-PKZ0-...CI-K4-PKZ4E-PKZ0-...CI-PKZ01E-PKZ01CI-K2-PKZ0-...CI-K4-PKZ4E-PKZ0-...CI-PKZ01E-PKZ01CI-K2-PKZ0-...CI-K4-PKZ4E-PKZ0-...CI-PKZ01E-PKZ01white 110 – 230 L-PKZ0(230V)082151230 – 400 L-PKZ0(400V)082152415 – 500 L-PKZ0(500V)082153green 110 – 230 L-PKZ0-GN(230V)082154230 – 400 L-PKZ0-GN(400V)082155415 – 500 L-PKZ0-GN(500V)082156red 110 – 230 L-PKZ0-RT(230V)082157230 – 400 L-PKZ0-RT(400V)08215810 off10 off5 off10 off10 off5 off10 off10 offFor <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616OrderingBusbar adapter8/19http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008BBARatedoperational voltageU eRated Terminaloperation capacityal currentI eAdapterwidthAdapterlengthV A mm mm QuantityDIN rail For use with Part no.Article no.Component adapter, 3 poleApproved to UL 508.For fitting to flat Cu-busbars with 60 mm between busbar centres, suitable for 5 mm and 10 mmbusbar thickness.For direct-on-line starters690 25 AWG 12(4 mmB)45 200 1 PKZM0 + DILM7PKZM0 + DILM9PKZM0 + DILM12PKZM0 + DILM15MSC-D-0,25-M7...bis MSC-D-16-M15...BBA0-25101451Pricesee pricelistStd.packNotes4 In combination withindividual componentsPKZM0 and DILM DOLstarter use PKZM0-XDM12.<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4690 32 AWG 10(6 mmB)45 200 2 PKZM0 + DILM17PKZM0 + DILM25PKZM0 + DILM32MSC-D-16-M17...bis MSC-D-32-M32...BBA0-32101452In combination withindividual componentsPKZM0 and DILM useelectrical contact modulePKZM0 XM32DE.690 63 AWG 8(10 mmB)55 260 2 PKZM4 + DILM17PKZM4 + DILM25PKZM4 + DILM32PKZM4 + DILM40PKZM4 + DILM50PKZM4 + DILM65BBA4L-63101459For electrical connection forPKZM4 + DILM17 –DILM32: MVS-LB0-0M-GPKZM4 + DILM40 –DILM65: PKZM4-XM65DEcan be used.690 63 AWG 8(10 mmB)72 260 2 PKZ2 + DILM7PKZ2 + DILM9PKZ2 + DILM12PKZ2 + DILM15PKZ2 + DILM17PKZ2 + DILM25PKZ2 + DILM32PKZ2 + DILM40BBA2L-63101480For electrical connection forPKZ2 + DILM7 – DILM12:MVS-LB0-00M-GPKZ2 + DILM15 – DILM32:MVS-LB0-0M-Gcan be used.For reversing starters690 25 AWG 12(4 mmB)690 32 AWG 10(6 mmB)90 200 1 PKZM0 + 2 xDILM7-01PKZM0 + 2 xDILM9-01PKZM0 + 2 xDILM12-01MSC-R-0,25-M7...bis MSC-R-12-M12...90 200 2 PKZM0 + 2 xDILM17-01PKZM0 + 2 xDILM25-01PKZM0 + 2 xDILM32-01MSC-R-16-M17...bis MSC-R-32-M32...BBA0R-25101453BBA0R-321014542 In combination withindividual componentsPKZM0 and DILM DOLreversing starter usePKZM0-XRM12.2 In combination withindividual componentsPKZM0 and DILM useelectrical contact modulePKZM0 XM32DE andreversing wiring set DILM32-XRL.


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/20OrderingBusbar adapterBBA<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Rated Ratedoperation operational voltage al currentU eI eTerminalcapacityAdapterwidthAdapterlengthDINrailV A mm mm QuantityFor use withComponent adapter, 3 poleApproved to UL 508.For fitting to flat Cu-busbars with 60 mm between busbar centres, suitable for 5 mm and 10 mmbusbar thickness.For starters with springloaded terminals690 16 AWG 14(2.5 mmB)45 200 2 PKZM0-C + DILMC7PKZM0-C + DILMC9PKZM0-C + DILMC12Part no.Article no.BBA0C-16101455Pricesee pricelistStd.packNotes4 off According to UL 508: I e= 12 A690 16 AWG 14(2.5 mmB)90 200 2 PKZM0-C + 2 xDILMC7-01PKZM0-C + 2 xDILMC9-01PKZM0-C + 2 xDILMC12-01BBA0RC-161014562 off According to UL 508: I e= 12 A<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>690 63 AWG 8(10 mmB)54 200 1 PKZM4 BBA4-631014574 off690 63 AWG 8(10 mmB)72 200 1 PKZ2 BBA2-631014584 offUniversal adapterFor universal use690 25 AWG 12(4 mmB)45 200 2 BBA0-25/2TS1014814 off Mounting rail can beoffset on 1.25 mm grid.Empty moduleWithout electrical contacts45 200 2 BBA0/2TS-L10148254 200 2 BBA4/2TS-L1014834 off Mounting rail can beoffset on 1.25 mm grid.4 off For use withimplementation ofreversing and star-deltastarters.Side mounted moduleCan be plugged into both sides9 200 BBA-XSM10148410 off Can be grouped on thebusbar adapter toextend mounting width


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616OrderingWiring sets8/21http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008PKZM0, PKZM4Wiring setDOL startersFor use withPKZM0 + DILM7PKZM0 + DILM9PKZM0 + DILM12PKZM0 + DILM15PKZM0 + DILM17PKZM0 + DILM25PKZM0 + DILM32Part no.Article no.PKZM0-XDM12283149PKZM0-XDM32283153Pricesee pricelistStd. packNotes1 off Comprised of:• Mechanical connection element for PKZM0 and contactor• Main current wiring between PKZM0 and contactor in tool-less plugconnection• Cable routingAs auxiliary contact DILA-XHIT...use a 5/291 off Comprised of:• Top-hat rail adapter plate• Main current wiring between PKZ and contactor<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Reversing startersPKZM0 + DILM7-01PKZM0 + DILM9-01PKZM0 + DILM12-01PKZM0-XRM122831851 off Comprised of:• Mechanical connection element for PKZM0 and contactor• Reversing starter main current wiring in tool-less plug connection• Control cables for electrical interlocking in tool-less plug connection:– K1M: A1 –K2M: 21– K1M: 21 –K2M: A1– K1M: A2 –K2M: A2• Cable routingAs auxiliary contact DILA-XHIT...use a 5/29Cannot be combined with AGM-PKZ0.PKZM0 + DILM17PKZM0 + DILM25PKZM0 + DILM32PKZM0-XRM322831891 off Comprised of:• Top-hat rail adapter plate• Reversing starter main current wiringStar-delta starterPKZM0 + DILM7PKZM0 + DILM9PKZM0 + DILM12PKZM0 + DILM15PKZM0-XSM122393461 off Comprised of:• Top-hat rail adapter plate• Main current wiring between PKZM0 and contactor• <strong>Electric</strong>al interlock between delta and star contactor• Use as contactor auxiliary switch DILA-XHIT... a 5/29PKZM0 + DILM17PKZM0 + DILM25PKZM0 + DILM32PKZM0-XSM322393471 off Comprised of:• Top-hat rail adapter plate• Main current wiring between PKZM0 and contactor<strong>Electric</strong> contact modulePKZM0 + DILM17PKZM0 + DILM25PKZM0 + DILM32PKZM4 + DILM40PKZM4 + DILM50PKZM4 + DILM65Top-hat rail adapter platePKZM0-XDM12PKZM0-XRM12PKZM0-XM32DE239349PKZM4-XM65DE101056PKZM0-XC452831325 off • Main current wiring between PKZM0 and contactor• Use only in combination with busbar adapter5 off • Main current wiring between PKZM4 and contactor• Use only in combination with busbar adapter4 off Comprised of:• 45 mm wide adapter plate• Connection element for side-by-side positioning of further platesPKZM4 + DILM40PKZM4 + DILM50PKZM4 + DILM65PKZM4-XC55/21010544 off Comprised of:• 55 mm wide adapter plate• Connection cams for further plates• For use with reversing and star-delta startersSide mountedmoduleConnection elementPKZM0-XS239354PKZM0-XCM23935910 off Can be grouped on the top-hat rail adapterExpansion of the mounting width by 9 mm.50 off For connection of several top-hat rail adapter


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/22OrderingThree-phase commoning linksB3…PKZ0, B3…PKZ0-U<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Circuit-breaker Length Unit width Part no.Article no.Number mm mmThree phase commoning link, power feed to terminals 1, 3, 5Protection against direct contact (touch-proof), U e = 690 V, u I = 63 Acan be lengthened by rotated mountingFor PKZM0-... without side mounted auxiliary contacts or voltage releases2 90 45 B3.0/2-PKZ00639613 135 45 B3.0/3-PKZ02322894 180 45 B3.0/4-PKZ00639605 225 45 B3.0/5-PKZ0232290Pricesee pricelistStd. packNotes10 off For parallel power feed to severalmotor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>on terminals 1, 3, 5For motor-<strong>protective</strong> <strong>circuit</strong>-breaker each with an auxiliary contact or trip-indicatingauxiliary contact fitted on the right2 99 45 + 9 B3.1/2-PKZ00449453 153 45 + 9 B3.1/3-PKZ00449464 207 45 + 9 B3.1/4-PKZ00449475 261 45 + 9 B3.1/5-PKZ004494810 off For parallel power feed to severalmotor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>on terminals 1, 3, 5For PKZM0-... with one auxiliary contact each and a trip-indicating auxiliary contactfitted on right or a voltage release fitted on left2 108 45 + 18 B3.2/2-PKZ00639634 234 45 + 18 B3.2/4-PKZ006395910 off For parallel power feed to severalmotor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>10 off on terminals 1, 3, 5Shroud for unused terminalsProtection against direct contact.For closing off non-used connections on the three phase commoning link B3...-PKZ0H-B3-PKZ003272120 offIncoming terminalBK25/3-PKZ00327205 off For three-phase commoning link,protected against accidentalcontact, U e = 690 V, I u = 63 AFor conductor cross-sections:2.5 – 25 mm 2 stranded2.5 – 16 mm 2 flexible with ferrulesAWG 14 – 6, for use on terminals 1,3, 5Three phase commoning link, power feed to terminals 2, 4, 6Protection against direct contact (touch-proof), U e = 690 V, u I = 63 Acan be lengthened by rotated mountingFor PKZM0-... without side mounted auxiliary contacts or voltage releases2 90 45 B3.0/2-PKZ0-U2923873 135 45 B3.0/3-PKZ0-U2923884 180 45 B3.0/4-PKZ0-U2923895 225 45 B3.0/5-PKZ0-U2928805 off For parallel power feed to severalmotor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>on terminals 2, 4, 6


OrderingThree-phase commoning links8/23http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008B3…PKZ0-U, B3…-PKZ4CircuitbreakerNumber mm mmLength Unit width Part no.Article no.For motor-<strong>protective</strong> <strong>circuit</strong>-breaker each with an auxiliary contact or trip-indicatingauxiliary contact fitted on the right2 99 45 + 9 B3.1/2-PKZ0-U2928813 153 45 + 9 B3.1/3-PKZ0-U2928824 207 45 + 9 B3.1/4-PKZ0-U292883Priceseeprice listStd. pack5 off For parallel power feed toseveral motor-<strong>protective</strong><strong>circuit</strong>-<strong>breakers</strong> on terminals2, 4, 6<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM45 261 45 + 9 B3.1/5-PKZ0-U292884Shroud for unused terminalsProtection against direct contact.For closing off non-used connections on the three phase commoning link B3...-PKZ0-UH-B3-PKZ0-U29288510 offIncoming terminalThree-phase commoning linkProtection against direct contact (touch-proof), U e = 690 V, u I = 128 ABK25/3-PKZ0-U29288610 off For three-phase commoninglink, protected againstaccidental contact, U e = 690 V,I u = 63 AFor conductor cross-sections:2.5 – 25 mm 2 stranded2.5 – 16 mm 2 flexible withferrulesFor use on the terminals 2, 4, 6For motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>/(high-capacity) compact starters without side-fittedauxiliary contact or voltage releases2 110 55 B3.0/2-PKZ42202201 off3 165 B3.0/3-PKZ42202214 220 B3.0/4-PKZ4220222For PKZM4 each with an auxiliary contact or trip-indicating auxiliary contact fitted on theright2 119 55 + 9 B3.1/2-PKZ42202231 off3 183 B3.1/3-PKZ42202244 247 B3.1/4-PKZ4220225For PKZM4 with one auxiliary contact each or trip-indicating auxiliary contact fitted on rightor a voltage release fitted on left2 128 55 + 18 B3.2/2-PKZ42202264 274 55 + 18 B3.2/4-PKZ42202271 off1 offShroud for unused terminalsProtection against direct contact.To cover unused terminals on three-phase commoning linkH-B3-PKZ422022810 offFor <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


8/24OrderingActuating voltagesPKZM01, PKZM0, PKZM4motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong><strong>Moeller</strong> HPL0211-2007/2008Shunt release, undervoltage releaseWhen ordered separatelyAC A-PKZ0(...) U-PKZ0(...)Article no. 1) Article no. 1)Standard voltage see price list see price list24V 50Hz 073181 073129110V 50Hz 073184 073132220V 50Hz 073186 073134230V 50Hz 073187 073135240V 50Hz 073188s 073136380V 50Hz 073189 073137400V 50Hz 073190 073138415V 50Hz 073191 073139120V 60Hz 073195 073143240 V 60 Hz 073198 073146440V 60Hz 082164 082161480V 60Hz 073199 073147Non-standard voltages with the exception of the shown standardvoltages 2). see price list see price list...V 50Hz (24 – 500V) 3) 982162...V 60Hz (24 – 600V) 3) 982163DCStandard voltage see price list see price list–http://catalog.moeller.net24V DC 073200 –073203 –Notes1) The article no. is formed from the combination of part no. and actuating voltage.2) With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated.3) Minimum order quantity: 10 offFor <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008<strong>Motor</strong> protection, system protection, conductor and cable protection110System overview<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>23PKZ28/25<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> PKZ21049587Basic unitsAdd-on functions6Mounting accessories<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> 1a Page 8/27Circuit-<strong>breakers</strong> 1a Page 8/27Contact module 6a Page 8/41High-capacity contact module 7a Page 8/41Auxiliary contacts 10a Page 8/35Current limiter 8a Page 8/35Voltage releases 4a Page 8/37Remote operators 5a Page 8/39Mounting/wiring 2a Page 8/44Door coupling handle IP65 9a Page 8/33Insulated enclosures 3a Page 8/33


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/26Ordering<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, <strong>circuit</strong>-<strong>breakers</strong>Ordering<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, <strong>circuit</strong>-<strong>breakers</strong>8/27PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerPKZ2<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netMax. motor ratingRateduninterruptedcurrentSetting rangeAC-3 I u Overload releases Short-<strong>circuit</strong> releases220 V230 V240 V380 V400 V415 V440 V 500 V 660 V690 VA I r I rmP P P P P A AkW kW kW kW kWhttp://catalog.moeller.netPart no.Article no.<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, Type “1” and Type “2” coordination0.09 0.12 0.18 0.25 0.25 0.6 0.4…0.6 5…8 PKZ2/ZM-0,60218590.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 PKZ2/ZM-10266050.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 PKZ2/ZM-1,60289780.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 PKZ2/ZM-2,40313510.75 1.5 1.5 2.2 3 4 2.4…4 35…55 PKZ2/ZM-4033724I >1.1 2.2 3 3 4 6 4…6 50…80 PKZ2/ZM-60360972.2 4 4 5.5 7.5 10 6…10 80…140 PKZ2/ZM-100384704 7.5 9 9 12.5 16 10…16 130…220 PKZ2/ZM-160408435.5 12.5 12.5 15 22 25 16…25 200…350 PKZ2/ZM-250432167.5 15 17.5 22 22 32 24…32 275…425 PKZ2/ZM-3204558911 20 22 24 30 40 32…40 350…500 PKZ2/ZM-40047962Circuit-<strong>breakers</strong>For protection of cables and conductors– – – – – 10 6…10 50…80 PKZ2/ZM-10-8050335– – – – – 16 10…16 80…140 PKZ2/ZM-16-8052708– – – – – 25 16…25 130…210 PKZ2/ZM-25-8055081– – – – – 32 24…32 160…280 PKZ2/ZM-32-8057454– – – – – 40 32…40 200…350 PKZ2/ZM-40-8059827Pricesee pricelistStd.pack<strong>Moeller</strong> HPL0211-2007/2008Notes1 off Single-phasing sensitivity toIEC/EN 60947-4-1Overload release, adjustableI r = 0.6 1.0 x I uShort-<strong>circuit</strong> release, adjustableI rm = 8.5 – 14 x I u factory set to12 x I uWorld market devices to IEC qUL/CSA1 off Overload release, adjustableI r = 0.6 – 1.0 x I uShort-<strong>circuit</strong> release, adjustableI rm = 5.0 – 8.5 x I u factory set to5 x I uNotes53AccessoriesPage3 Standard auxiliary contact a 8/355 Trip-indicating auxiliary contact a 8/356 Shunt release, undervoltage release a 8/377 Remote operators a 8/398 Contact module, high-capacity contact module, current limiter a 8/419 Clip plate a 8/44Additional accessories a 8/33Rated ultimate short-<strong>circuit</strong> breaking capacitya Technical dataManual a 8/44Can be snap fitted to IEC/EN 60715 with 7.5or 15 mm height9876PKZ2PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerI >


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker8/28OrderingCompact starters, high-capacity compact starters<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netMax. motor ratingRateduninterruptedcurrentSetting rangeAC-3 Overload releases Short-<strong>circuit</strong>releases220 V230 V240 V380 V400 V415 V440 V 500 V 660 V690 VP P P P P I u A AkW kW kW kW kW AI rI rmhttp://catalog.moeller.netCompact starters, Type 1“ coordination0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 PKZ2/ZM-1/SE1A/11(230V50HZ,240V600633640.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 PKZ2/ZM-1,6/SE1A/11(230V50HZ,240V0633720.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 PKZ2/ZM-2,4/SE1A/11(230V50HZ,240V0633820.75 1.5 1.5 2.2 3 4 2.4…4 35…55 PKZ2/ZM-4/SE1A/11(230V50HZ,240V600633921.1 2.2 3 3 4 6 4…6 50…80 PKZ2/ZM-6/SE1A/11(230V50HZ,240V600634022.2 4 4 5.5 7.5 10 6…10 80…140 PKZ2/ZM-10/SE1A/11(230V50HZ,240V6063412L4 7.5 9 9 12.5 16 10…16 130…220 PKZ2/ZM-16/SE1A/11(230V50HZ,240V6063422Ι >5.5 12.5 12.5 15 22 25 16…25 200…350 PKZ2/ZM-25/SE1A/11(230V50HZ,240V6063432A1 13 217.5 15 17.5 22 22 32 24…32 275…425 PKZ2/ZM-32/SE1A/11(230V50HZ,240V6063442A2 14 2211 18.5 22 24 30 36 32…40 350…500 PKZ2/ZM-40/SE1A/11(230V50HZ,240V6T063452High-capacity compact starters, Type 2“ coordination0.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 PKZ2/ZM-1/S(230V50HZ,240V60HZ)0634720.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 PKZ2/ZM-1,6/S(230V50HZ,240V60HZ)0634820.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 PKZ2/ZM-2,4/S(230V50HZ,240V60HZ)0634920.75 1.5 1.5 2.2 3 4 2.4…4 35…55 PKZ2/ZM-4/S(230V50HZ,240V60HZ)0635021.1 2.2 3 3 4 6 4…6 50…80 PKZ2/ZM-6/S(230V50HZ,240V60HZ)0635122.2 4 4 5.5 7.5 10 6…10 80…140 PKZ2/ZM-10/S(230V50HZ,240V60HZ)063522L4 7.5 9 9 12.5 16 10…16 130…220 PKZ2/ZM-16/S(230V50HZ,240V60HZ)0635325.5 12.5 12.5 15 22 25 16…25 200…350 PKZ2/ZM-25/S(230V50HZ,240V60HZ)I >063542A1 13 217.5 15 17.5 22 22 32 24…32 275…425 PKZ2/ZM-32/S(230V50HZ,240V60HZ)06355222 A2 14I >>11 18.5 22 24 30 36 32…40 350…500 PKZ2/ZM-40/S(230V50HZ,240V60HZ)063562TPKZ2/ZMPart no.Article no.<strong>Moeller</strong> HPL0211-2007/2008Pricesee pricelistOrderingCompact starters, high-capacity compact startersStd. pack Notes Notes1 off 1 M/1 B auxiliarycontact built intothe contact module1 off Rated short-<strong>circuit</strong>currentI q = 100 kA/400 VHigh-capacitycontact module hasbuilt-in auxiliarycontacts: 1 M/1 B53 4AccessoriesPage3 Standard auxiliary contact a 8/354 Standard auxiliary contact a 8/355 Trip-indicating auxiliary contact a 8/356 Shunt release, undervoltage release a 8/377 Remote operators a 8/399 Clip plate a 8/44Other accessories a 8/33Further actuating voltages a 8/45Manual a 8/44Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102Supplied fitted to C-PKZ2 clip plate, can be snap fitted to one or two IEC/EN 60715 top-hat rails, height 15 mmOverload release, adjustable I r = 0.6 – 1.0 x I uAdjustable short-<strong>circuit</strong> release I rm = 8.5 – 14 x I u setex-works to 12 x I uPTB 02 ATEX 3152Observe manual.9PKZ2/ZM768/29PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker


8/30Ordering<strong>Motor</strong> protection modulesPKZ2, PKZ2/S…<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netPKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerBasic unit, 3-poleRateduninterrupted currentI uAPart no.Article no.40 PKZ2026606Pricesee pricelistRGStd.pack1 offCircuit diagram forZM...PKZ2M...PKZ2PKZ2 basic unit with S-PKZ2 high-capacity contactmodule fitted (1 M, 1 B)Supplied on C-PKZ2 clipplate. Cannot be combinedwith Z...-0.6-PKZ2.40 PKZ2/S(230V50HZ)063572ZMR...PKZ2I > I >PKZ2 basic unit with SE1A/11-PKZ2 contact modulefitted (1 M, 1 B) Supplied onC-PKZ2 clip plate. Cannotbe combined with Z...-0.6-PKZ2.40 PKZ2/SE1A/11(230V50HZ)082142I >Adjustable:H q manual position orA q automatic positionFor EEx e applications the 95/96 N/C contact must always be usedto de-energize the (high-capacity) contact module or contactor.HA95969798<strong>Motor</strong>-<strong>protective</strong> trip blocks ZMR-...-PKZ2 cannot be combinedwith U/A voltage releases and RE/RS remote operators.Further actuating voltages a 8/45Manual a 8/44Max. motor ratingRateduninterruptedcurrentSetting rangePart no.Article no.Pricesee pricelistStd.packAC-3220 V230 V240 V380 V400 V415 V440 V 500 V 660 V690 VOverloadreleasesShort<strong>circuit</strong>releasesP P P P P I u I r I rmkW kW kW kW kW A A A<strong>Motor</strong>-<strong>protective</strong> trip blocks, 3-poleWith overload release0.09 0.12 0.18 0.25 0.25 0.6 0.4…0.6 5…8 ZM-0,6-PKZ20242320.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 ZM-1-PKZ20289790.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 ZM-1,6-PKZ20313520.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 ZM-2,4-PKZ20337250.75 1.5 1.5 2.2 3 4 2.4…4 35…55 ZM-4-PKZ20360981.1 2.2 3 3 4 6 4…6 50…80 ZM-6-PKZ20384712.2 4 4 5.5 7.5 10 6…10 80…140 ZM-10-PKZ20408444 7.5 9 9 12.5 16 10…16 130…220 ZM-16-PKZ20432175.5 12.5 12.5 15 22 25 16…25 200…350 ZM-25-PKZ20455907.5 15 17.5 22 22 32 24…32 275…425 ZM-32-PKZ204796311 20 22 24 30 40 32…40 350…500 ZM-40-PKZ20503361 off Single-phasing sensitivityto IEC/EN 60947-4-1Suitable for the protectionof EEx e motorsPTB Certificate No.: 3.53-388.299Extension to ATEX appliedforOverload releases,adjustableI r = 0.6 – 1.0 x I uAdjustable short-<strong>circuit</strong>releaseI rm = 8.5 – 14 x I uFactory set to 12 x I uFor <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008220 – 240 V RateduninterAC-3220 V230 V240 V380 V400 V415 V440 V 500 V 660 V690 VruptedcurrentSetting rangeOverloadreleasesP P P P P I u I r I rmkW kW kW kW kW A A AShort-<strong>circuit</strong>releasesOrdering<strong>Motor</strong> protection modulesPart no.Article no.<strong>Motor</strong>-<strong>protective</strong> trip blocks, 3-poleWith overload relay function, with Hand/Auto position0.09 0.12 0.18 0.25 0.25 0.6 0.4…0.6 5…8 ZMR-0,6-PKZ20339430.12 0.25 0.25 0.37 0.55 1 0.6…1 8…14 ZMR-1-PKZ20339500.25 0.55 0.55 0.75 1.1 1.6 1…1.6 14…22 ZMR-1,6-PKZ20339520.37 0.75 1.1 1.1 1.5 2.4 1.6…2.4 20…35 ZMR-2,4-PKZ20339550.75 1.5 1.5 2.2 3 4 2.4…4 35…55 ZMR-4-PKZ20339571.1 2.2 3 3 4 6 4…6 50…80 ZMR-6-PKZ20339662.2 4 4 5.5 7.5 10 6…10 80…140 ZMR-10-PKZ20339674 7.5 9 9 12.5 16 10…16 130…220 ZMR-16-PKZ20339685.5 12.5 12.5 15 22 25 16…25 200…350 ZMR-25-PKZ20339697.5 15 17.5 22 22 32 24…32 275…425 ZMR-32-PKZ203397311 20 22 24 30 40 32…40 350…500 ZMR-40-PKZ2033975Without overload release– – – – – 0.6 –… 5…8 M-0,6-PKZ2004537– – – – – 1 –… 8…14 M-1-PKZ2004538– – – – – 1.6 –… 14…22 M-1,6-PKZ2004539– – – – – 2.4 –… 20…35 M-2,4-PKZ2004540– – – – – 4 –… 35…55 M-4-PKZ2004541– – – – – 6 –… 50…80 M-6-PKZ2004542– – – – – 10 –… 80…140 M-10-PKZ2004543– – – – – 16 –… 130…220 M-16-PKZ2004544– – – – – 25 –… 200…350 M-25-PKZ2004545– – – – – 32 –… 275…425 M-32-PKZ2004546– – – – – 40 –… 350…500 M-40-PKZ2004547ZM(R)…-PKZ2, M-PKZ2Pricesee pricelistStd.pack1 off Phase-failure sensitivityand overload/short<strong>circuit</strong>release settingoptions and PTB, seeabove.When using motor<strong>protective</strong>trip blockswith an overload relayfunction, the motor<strong>protective</strong><strong>circuit</strong>-breakerdoes not trip in the eventof an overload. Theoverload indication isproduced by means oftwo auxiliary contacts.Different potentials maybe applied to the twoauxiliary contacts.1 off Adjustable short-<strong>circuit</strong>releaseI rm = 8.5 – 14 x I uFactory set to 12 x I u8/31PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerNotesWhen using the M-...-PKZ2 as short-<strong>circuit</strong> protection for motors with heavy starting duty, the rated operational current Ie must be up-ratedwhen engineering by the following factors:CLASS Factor5 1.010 1.015 1.2220 1.4125 1.5830 1.7335 1.8940 2.0


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker8/32Basic unit, 3-poleOrderingComponents for distribution <strong>circuit</strong> protectionPKZ2, PKZ24, ZM…-PKZ…RateduninterruptedcurrentI uAPart no.Article no.40 PKZ2026606Pricesee pricelistStd. pack1 off<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netBasic unit, 4-pole40 PKZ240045211 offCircuit diagram forZM... -PKZ2(4)M... -PKZ2(4)I > I >RateduninterruptedcurrentSetting rangeOverloadreleasesShort-<strong>circuit</strong>releasesPart no.Article no.Pricesee pricelistRGStd. packI u I r I rmA A ATrip block for distribution <strong>circuit</strong> protection3-poleWith overload release10 6…10 50…80 ZM-10-8-PKZ206220116 10…16 80…140 ZM-16-8-PKZ205982825 16…25 130…210 ZM-25-8-PKZ205745532 24…32 160…280 ZM-32-8-PKZ205508240 32…40 200…350 ZM-40-8-PKZ20527094-poleWith overload releases in all 4 poles10 6…10 50…80 ZM-10-8-PKZ2400452616 10…16 80…140 ZM-16-8-PKZ2400452525 16…25 130…210 ZM-25-8-PKZ2400452432 24…32 160…280 ZM-32-8-PKZ2400452340 32…40 200…350 ZM-40-8-PKZ240045221 off Overload releases, adjustableI r = 0.6 – 1.0 x I uAdjustable short-<strong>circuit</strong> releaseI rm = 5 – 8.5 x I u factory set to 5 x I u1 off Overload releases, adjustableI r = 0.6 – 1.0 x I uAdjustable short-<strong>circuit</strong> releaseI rm = 5 – 8.5 x I u factory set to 5 x I uCircuit-<strong>breakers</strong> PKZ24/ZM-...-8 protect in all 4-poles.


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008Insulated enclosures for surface mountingFor motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, 3- or 4-pole <strong>circuit</strong>-<strong>breakers</strong>Degree of protection IP40 Coverwith aperture dimensioned toaccommodate front of breaker,comes with blanking stripDegree of protection IP54 Formounting of (R)H-PKZ2 doorcoupling handleDegree of protection IP54 Formounting of (R)H-PKZ2 doorcoupling handleFor use withPKZ2/ZM-... +NHI +AGM + U or A or RE orRS PKZ24/ZM-... + NHI+ AGM + U or APKZ2/ZM-... + NHI +AGM + U or A + (R)HPKZ24/ZM-... + NHI +AGM + U or A + (R)HColourPart no.Article no.CI19EA-PKZ2026234CI19EB-PKZ2028607CI19ED-PKZ24005145OrderingInsulated enclosuresCI…-PKZ, E…-PKZPricesee pricelistStd. packNotes1 off Built-in IEC/EN 60715top-hat rail, separateterminals for PE(N)- andNincl. cable entry 2 x PG16/21/29L-PKZ0 indicator lightcan be fitted8/33PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerFor 3-pole compact starters, high-capacity compact starters, combination <strong>circuit</strong>-<strong>breakers</strong> (Kombi)Degree of protection IP40 Coverwith aperture dimensioned toaccommodate front of breaker,comes with blanking stripDegree of protection IP54 Formounting of (R)H-PKZ2 doorcoupling handlePKZ2/ZM-.../S(E1A) +NHI + AGM + RE or RSor U or APKZ2/ZM-.../S + NHI +AGM + U or A + (R)HCI23EA-PKZ2087936CI23EB-PKZ20903091 off Complete with L3/5-CI23 mounting plateWill accept compactstarter or PKZ2/ZM-.../Shigh-capacity compactstarter without clipplateInsulated enclosures for flush mountingFor motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, 3- or 4-pole <strong>circuit</strong>-<strong>breakers</strong>Neutral terminalFor connection of a 5th conductorDegree of protection IP41 Greyfront plate with retaining frameIntegral PE(N) terminalDegree of protection IP54 (R)H-PKZ2 door coupling handle alsorequired as standardPKZ2/ZM-... + NHI +AGM PKZ2/ZM-... + Uor A PKZ24/ZM-...+ NHI + AGMPKZ2/ZM-...+U or A (undervoltageor shunt release)PKZ24/ZM-...PKZ2/ZM-... + NHI +AGM PKZ2/ZM-... + Uor A PKZ24/ZM-...+ NHI + AGMPKZ2/ZM-...+U or A (undervoltageor shunt release)PKZ24/ZM-...E-PKZ2E54-PKZ2E-PKZ2003218E54-PKZ2033939N-PKZ20032191 off For mounting in sideplate or door.Vertical mountingposition.L-PKZ0 indicator lightcan be fitted1 offDoor coupling handlesDegree of protection IP65For use as main switch to IEC/EN 60204For use in MCC distributionboards with PKZ2 turnedthrough 90°. For use as mainswitch according to EN 60204BlackBlackPKZ2-XH106127PKZ2-XH-MCC1061301 off Lockable in 0 or IpositionSuitable for 3 padlockswith 4 – 8 mm haspthicknessFor use as a main switch withEmergency-Stop function, toEN 60204RedyellowPKZ2-XRH106128Plug-fit extension shaft for door coupling handleCan be extended as required for mounting depths from 171 - 300 mmPKZ2-XAH1061291 off


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/34OrderingAccessoriesOrderingAccessories8/35PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerNHI…-PKZ2<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netContacts Contact diagram Contact sequence Part no.N/O = NormallyopenN/C = Normallyclosedhttp://catalog.moeller.netOrder number forseparate ordersStandard auxiliary contactsFor motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, <strong>circuit</strong>-<strong>breakers</strong>, and (high-capacity) compact starters1 N/O 1 N/C 1.13 1.21NHI11-PKZ2L1L2L3090677NHI112 N/O 2 N/C 1.14 1.22NHI22-PKZ2L1L2L3097796I >NHI2-11SPKZ 2(4)/ZM...NHI11oderNHI221.13 1.211.31 1.43Pricesee pricelist<strong>Moeller</strong> HPL0211-2007/2008Std. pack1 off Can be fitted to <strong>circuit</strong>-breaker and (high-capacity) compactstarter.1 offCan be combined with AGM trip-indicating auxiliarycontactsNotesNHI…-PKZ217PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker1.14 1.22 1.32 1.44For (high-capacity) compact starters1 N/O 1 N/C 1.21 1.43 1.21 43NHI11S-PKZ2L1L2L31.13 1.21 1.13 1.31 1.13 31007623NHI112 N/O 2 N/C NHI22S-PKZ2L1L2L3000504NHI2-11S1321I >A12 x 1 N/O 2 x 1 N/C NHI2-11S-PKZ2L1L2L3A214 220099961 off Can be fitted to the starter combinationCan be combined with AGM trip-indicating auxiliarycontacts,AccessoriesPage1 <strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker, <strong>circuit</strong><strong>breakers</strong>a 8/277 Remote operators a 8/39Additional accessories a 8/33297NHI2-11SI >>PKZ 2(4)/ZM.../S1.14 1.22 1.14 1.32 1.14 321.22 1.44 1.22 44NHI 11S NHI 22S NHI 2-11STrip-indicating auxiliary contacts with short-<strong>circuit</strong> indicatorFor motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, <strong>circuit</strong>-<strong>breakers</strong>, and (high-capacity) compact starters2 x 1 N/O 2 x 1 N/C Trip"+"AGM2-11-PKZ2017115L1L2L3AGMI >"+"PKZ 2(4)/ZM... AGM 2-11"I >"4.43 4.31 4.21 4.134.44 4.32 4.22 4.141 off Differential remote indication:a) General trip indication “+", overload,b) Short-<strong>circuit</strong> tripCan be fitted to <strong>circuit</strong>-breaker and (high-capacity) compactstarter.Can be combined with NHI... or NHI...S standard auxiliarycontactsAccessoriesPage2 (High-capacity) compact starter a 8/297 Remote operators a 8/399 Clip plate a 8/44Additional accessories a 8/33Short-<strong>circuit</strong> indicatorsFor motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>, <strong>circuit</strong>-<strong>breakers</strong>, and (high-capacity) compact startersTrip "+"L1L2L3"+"– K-AGM-PKZ20218615 off Local short-<strong>circuit</strong> indication by resettable indicator.Can be used in <strong>circuit</strong>-<strong>breakers</strong> and (high-capacity) compactstarters" "On/OffL1L2L3"+"" "Current limitersTo increase the switching capacity of non-inherently short-<strong>circuit</strong>-proof motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> to 100 kA/500 V– LCL-PKZ2076439I >>T1 off Max. rated operational voltage U e = 690 VRated uninterrupted current I u = 40 ACan be retrofitted to <strong>circuit</strong>-breaker or can be fittedindividually with EZ plinthCan be used as individual contactorC-PKZ2 clip plate required as standard19AccessoriesPage1 <strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker, <strong>circuit</strong>breakera 8/279 clip plates a 8/44Additional accessories a 8/33


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/36OrderingAccessoriesOrderingAccessories8/37PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerShunt releasesFor AC and DCA-PKZ…, U-PKZ…<strong>Moeller</strong> HPL0211-2007/2008Contact sequence Contact diagram Actuating voltageVoltage and frequency combination possible with one coil in the voltage release.C1C224 V DC 48 V DC 60 V DC24 V 50Hz 48 V 50Hz24 V 60 Hz 48 V 60Hz110 V DC 125 V DC 250 V DC110 V 50Hz 127 V 50Hz 220 V 50Hz230 V 50Hz 240 V 50Hz110 V 60Hz 120 V 60 Hz 208 V 60 Hz220 V 60 Hz 240 V 60Hz380 V 50Hz 400 V 50Hz 415 V 50Hz440 V 50Hz 500 V 50Hz480 V 60 Hz 600 V 60 Hzhttp://catalog.moeller.nethttp://catalog.moeller.netTypeOrder number for separateordersA-PKZ2-A063967A-PKZ2-B063964A-PKZ2-C063930Pricesee pricelistRG<strong>Moeller</strong> HPL0211-2007/2008Can be fitted to motor-<strong>protective</strong> <strong>circuit</strong>-breaker, <strong>circuit</strong>breaker,(high-capacity) compact starterCan be combined with remote operator.Notes1A-PKZ…, U-PKZ…7AccessoriesPage1 <strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker, <strong>circuit</strong><strong>breakers</strong>a 8/277 Remote operators a 8/39Additional accessories a 8/33PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerUndervoltage releases, non-delayedWithout auxiliary contactD1U


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/38OrderingRemote operatorsOrderingRemote operators8/39PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerRE-PKZ2 remote operatorActuation via auxiliary contactRE-PKZ, RS-PKZ<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netContact sequence Circuit diagram for pulsed operation Part no.Article no.OFF and RESET separate OFF equals RESETRS-PKZ2 remote operatorActuation from PLC semi-conductor outputsLI >TLI >T7274A20 A40 B2072 74A20 A30 A0IL(+)N(-)72 74LINECONTROLA20 A40 B20OON OFF RESET3334IL(+)N(-)72 74LINECONTROLA20 A40 B20OON OFF RESET3334Power and control sections have the same potential.Can be actuated by a single pulse (f 2 VA/W, 15 ms)or by maintained contact. When activated, the powersection is energized directly from the mains supply(700 VA/W, 30 ms). Control section can be activatedby: NHI, AGM, ETS4-VS3, EK..., PLC with isolatedcontacts without RC suppressor.http://catalog.moeller.netRE-PKZ2(220-240V50/60HZ,DC)063676RE-PKZ2(110-120V50/60HZ,DC)063673RE-PKZ2(24V50/60HZ,DC)063670– L(+)N(-)RS-PKZ2(220-240V50/60HZ,DC)063688ONPower and control sections electrically isolated fromone another. Control section always 24 V. Safeisolation between power and control section isassured. Can be actuated by a single pulse (f 2 VA/W, 15 ms) or by maintained contact. The controlsection can be activated directly from the PLCelectronic outputs (24 V DC). When activated, thepower section is energized directly from the mainssupply (700 VA/W, 30 ms).RS-PKZ2(380-415V50/60HZ)063689– RS-PKZ2(24V50/60HZ,DC)CONTROL34063682ION72 74A20 A30 A0L(+)LINECONTROLOFF/RESETN(-)72 74LINEA20 A30 A0OOFF/RESET333424V DC3324V DCAC/DC<strong>Moeller</strong> HPL0211-2007/2008Pricesee pricelistStd. pack1 off Can be fitted to <strong>circuit</strong>-breakerand (high-capacity) compact1 off starter. Remote On/Off switchingof <strong>circuit</strong>-breaker and trip reset toOFF.1 off Remote operator can be switchedoff locally and the thumb-griplocked using 6 mm padlock.Suitable for use with AC or DC.Can be combined with U, U-HI20,UVHI-PKZ2 voltage releases or A-PKZ2.NHI standard auxiliary contact isalways required in addition forcombination of <strong>circuit</strong>-breaker1 off and RE/RS-PKZ2 remote operator.Cannot be used in conjunction1 offwith (R)H-PKZ2 door-couplinghandle.Mounting is possible in On andOff switch positions.Internal electronic interlockingalways makes “Off” a priority.A green background to the slideindicates the q “Hand” positiomwith contacts (33/34) open.A red background to the slideindicates the q “Auto” position1 off with contacts (33/34) closed.In the Hand’’ position, remoteswitching is not possible.Notes53Accessories1Page1 <strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker, <strong>circuit</strong>-<strong>breakers</strong> a 8/273 Standard auxiliary contact a 8/355 Trip-indicating auxiliary contact a 8/35Additional accessories a 8/33542RE-PKZ, RS-PKZ9AccessoriesPage2 (high-capacity) compact starters a 8/294 Standard auxiliary contact a 8/355 Trip-indicating auxiliary contact a 8/359 Clip plate a 8/44PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerMinimum command time:ONCONTROLIONOf 15t (ms)OFF/RESETCONTROLIOFF/RESETOf 15t (ms)LINEf 300IONCONTROLOOFFMain contactF 30 F 30t (ms)


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/40OrderingContact moduleOrderingContact module8/41PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerContact moduleSE…/…-PKZ, VGSPKZ<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netContact sequence 220 – 240 V Auxiliary contacts For use with Part no.Article no.TA1A2High-capacity contact module with current limiting contactsTT1314I >>TA1 13 21A214 22A1 13 23A2 14 24A1A213 2114 22A1 13 23A2 14 2424 V DCAC-3 N/O =Normally220 V230 V240 V380 V400 V415 V440 V 500 V 660 V690 VP P P P PkW kW kW kW kWN/C =Normallyhttp://catalog.moeller.net11 20 22 24 30 1 N/O 1 N/C PKZ2(4) SE1A/11-PKZ2(230V50HZ)06371111 20 22 24 30 2 M – PKZ2(4) SE1A/20-PKZ2(230V50HZ)06371811 20 22 24 30 1 M – PKZ2(4) SE1A-G-10-PKZ2(24VDC)05885611 20 22 24 30 1 N/O 1 N/C PKZ2(4) S-PKZ2(230V50HZ)06369611 20 22 24 30 2 N/O – PKZ2(4) S/HI20-S-PKZ2(230V50HZ)063703Pricesee pricelist<strong>Moeller</strong> HPL0211-2007/2008Std. pack1 off Clip plate for snap fitting the combination to beordered separately. Can be fitted to 3 or 4-pole<strong>circuit</strong>-breaker. When combined with a clip platecan be snap fitted to one IEC/EN 60715 top-hatrail with 15 mm height or two with 15 mmheight.Can be mounted separately using base (seebelow), RC suppressor on request.DC version: The coil cannot be changed. TheHI10-S-PKZ2 integral auxiliary contact is freelyconfigurable. The auxiliary contact cannot bechanged.DC version with varistor suppressor present.High-capacity contact modules with serial no. 01suitable for mounting with MV-PKZ2.1 offNotes5SE…/…-PKZ, VGSPKZ3 41AccessoriesPage1 <strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker, <strong>circuit</strong><strong>breakers</strong>a 8/273 Standard auxiliary contact a 8/354 Standard auxiliary contact a 8/355 Trip-indicating auxiliary contact a 8/356 Shunt release, undervoltage release a 8/377 Remote operators a 8/399 Clip plate a 8/44Further actuating voltages a 8/46Additional accessories a 8/33976PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerI >>TA1A2131424 V DC11 20 22 24 30 1 N/O – PKZ2(4) S-G-PKZ2(24VDC)070921I >>TSuppressor <strong>circuit</strong> Varistor suppressorA1A224 – 48 V AC – – – – – – – S(E1A)-...-PKZ2 VGSPKZ48063974110 – 250 V AC – – – – – – – VGSPKZ250063973380 – 415 V AC – – – – – – – VGSPKZ41506397210 off For (high-capacity) contact modules with 50-60Hz AC operationBases for separate mounting– – – – – – – – – S(E1A)-...-PKZ2CL-PKZ2EZ-PKZ20285961 off For retrofitting of (high-capacity) contact moduleor current limiter, separate mountingWith separate contacts also provides fixing basefor HI11-S/EZ-PKZ2 auxiliary contacts.Can be snap fitted to an IEC/EN 60715 top-hatrail, or screw fixing M4


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/42OrderingAccessories for contact modulesOrderingAccessories for contact modules8/43PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerControl <strong>circuit</strong> terminalHI…-PKZ2<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netContacts Contact diagram Contact sequence Part no.N/O = Normally N/C = NormallyArticle no.openclosedAuxiliary contacts for (high-capacity) contact module, separate mountinghttp://catalog.moeller.netST-PKZ2010998Pricesee price list<strong>Moeller</strong> HPL0211-2007/2008Std. packNotesHI…-PKZ23 off 1 set = 2 offComplies with IEC and UL/CSAFast-on connectors can be fitted (insulated/non-insulated) 2.8 mmMax. cross-section 0.5 – 1 mm 2 , 20 – 16 AWGMax. current tapped off 1 A or 15 % of set valueIncrease setting of overload release accordingly.Enables control <strong>circuit</strong> supply to be tapped off between motor-<strong>protective</strong> <strong>circuit</strong>-breaker and(high-capacity) contact modulePKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerCan be fitted on side of base for separate mounting1 N/O 1 N/COn31 43HI11-S/EZ-PKZ2090305L1L2L31 off10HIOffL1L2L3HI32 44Auxiliary contacts for (high-capacity) contact moduleAuxiliary contacts to replace integral auxiliary contacts in (high-capacity) contact module.Replacement not possible with SE1A-G-10-PKZ2 contact module or S-G-PKZ2 high-capacity contact module.1 N/O 1 N/C – – HI11-S-PKZ20339362 N/O – – HI20-S-PKZ2033935Mechanical interlockFor mechanically interlocking two separately mounted (high-capacity) contact modules or two (high-capacity) compact starters.Four end brackets suppliedCan be combined with S-PKZ2 high-capacity contact module Serial No. 01.– – MV-PKZ20339381 off1 off1 offAccessoriesPage8 High-capacity contact module a 8/4110 Base for separate mounting a 8/41Further actuating voltages a 8/468


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/44OrderingAccessoriesPKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerC-PKZ, B3…-PKZFor use withClip plateFor optional snap fitting and M4 screw fixing of <strong>circuit</strong>-breaker with (highcapacity)contact module or current limiterCan be used with AD busbar adapterPart no.Article no.C-PKZ2052710<strong>Moeller</strong> HPL0211-2007/2008Pricesee pricelistStd. packhttp://catalog.moeller.net2 off Can be used with AD busbarCan be snap fitted to one IEC/EN 60715top-hat rail, height 15 mm, or two tophatrails, greater than 10 mmThree-phase commoning linkFor wiring 3 PKZ2s, space is provided for either 2auxiliary contacts or 2 voltage releasesFor wiring of 2 PKZ2s, space is provided for either1 auxiliary contact or 1 voltage releaseB3.1/3-PKZ2033940B3.1/2-PKZ20639695 off Can be extended to several PKZ2s byrotated mounting, protected againstaccidental contactU e = 690 V, u I = 120 A, short-<strong>circuit</strong>5 offproofIncoming terminalFor three-phase commoning link, protected against accidental contactU e = 690 V, u I = 120 A– BK50/3-PKZ2033941Shroud for unused terminalsProtection against direct contact.To cover unused terminals on three-phase commoning link– H-B3-PKZ20639682 off For connection of:max. 1 x 50 mm 2 or 2 x 35 mm 2 ;above one another min. 1 x 1mm 2 or 2x 1 mm 210 off Snap-fitting option must be available onthe three-phase commoning linkPadlocking featureFor locking rear mounting <strong>circuit</strong>-<strong>breakers</strong> in the OFF position when thepanel door is open.– SVB-PKZ20503375 off Suitable for 3 padlocks with 5 – 8 mmhasp thicknessCoding pinsFor coding the trip block to match the PKZ2(4) basic unit Coding in binary– CS-PKZ20550831 offDocumentationPKZM2 motor<strong>protective</strong><strong>circuit</strong><strong>breakers</strong>,overloadmonitoring of EEx eGerman/EnglishAWB1210-1485D/GB2661661 off


OrderingActuating voltages8/45http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008Compact starterContact modules with 1 N/O and 1 N/C contactACPKZ2/ZM-1/SE1A/11(...)PKZ2/ZM-1.6/SE1A/11(...)PKZ2/ZM-2.4/SE1A/11(...)PKZ…/S…PKZ2/ZM-4/SE1A/11(...)PKZ2/ZM-6/SE1A/11(...)Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1)Standard voltage see price list see price list see price list see price list see price list230V 50Hz,063364 063372 063382 063392 063402240V 60Hz110V 50/60Hz – – – – 063408230V 50/60Hz 063369 063379 063389 063399 063409PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerCompact starterContact modules with 1 N/O and 1 N/C contactACPKZ2/ZM-10/SE1A/11(...)PKZ2/ZM-16/SE1A/11(...)PKZ2/ZM-25/SE1A/11(...)PKZ2/ZM-32/SE1A/11(...)PKZ2/ZM-40/SE1A/11(...)PKZ2/SE1A/11(...)Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1)Standard voltage see price list see price list see price list see price list see price list see price list230V 50Hz,063412 063422 063432 063442 063452 082142240V 60Hz110V 50/60Hz 063418 063428 063438 063448 063458 –230V 50/60Hz 063419 063429 063439 063449 063459 082148High-capacity compact starterContact modules with 1 N/O and 1 N/C auxiliary contactAC PKZ2/ZM-1/S(...) PKZ2/ZM-1.6/S(...) PKZ2/ZM-2.4/S(...) PKZ2/ZM-4/S(...) PKZ2/ZM-6/S(...)Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1)Standard voltage see price list see price list see price list see price list see price list230V 50Hz,063472 063482 063492 063502 063512240V 60Hz110V 50/60Hz 063478 063488 063498 063508 063518230V 50/60Hz 063479 063489 063499 063509 063519High-capacity compact starterContact modules with 1 N/O and 1 N/C auxiliary contactACPKZ2/ZM-10/S(...)PKZ2/ZM-16/S(...)PKZ2/ZM-25/S(...)PKZ2/ZM-32/S(...)PKZ2/ZM-40/S(...)PKZ2/S(...)Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1) Article no. 1)Standard voltage see price list see price list see price list see price list see price list see price list110V 50Hz,– – – – – 063570120V 60Hz230V 50Hz,063522 063532 063542 063552 063562 063572240V 60Hz24V 50/60Hz – – – – – 063577110V 50/60Hz 063528 063538 063548 063558 063568 –230V 50/60Hz 063529 063539 063549 063559 063569 063579Notes1) The article no. is formed from the combination of part no. and actuating voltage. Devices with dual-voltage coils are to beordered under a single order number.For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


8/46<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker PKZ2Actuating voltagesPKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerU-PKZ, S-PKZ<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netUndervoltage releaseWhen ordered separatelyAC U-PKZ2(...) U-HI20-PKZ2(...) UVHI-PKZ2(...)Article no. 1) Article no. 1) Article no. 1)Standard voltage see price list see price list see price list24V 50Hz 055085 063649 –110V 50Hz,– 063655 –120V 60Hz220V 50Hz,065685 063656 –240V 60Hz230V 50Hz,065766 065768 065770240V 60Hz400V 50Hz,065767 – –440V 60Hz24V 50/60Hz – 063659 –Non-standard voltages with the exception of the shownstandard voltages 2) .– see price list –...V 50Hz (24 – 600V) – 907537 3) –...V 60Hz (24 – 600V) – 907538 3) –DCStandard voltage see price list – –24V DC 014463 – –48V DC 028701 – –Notes1) The article no. is formed from the combination of part no. and actuating voltage.Devices with dual-voltage coils are to be ordered under a single order number.2) With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated.3) Minimum order quantity: 10 units.(High capacity)contact moduleSingle coil for (high-capacity) contact moduleAC S-PKZ2(...) S/HI20-S-PKZ2(...) SE1A/11-PKZ2(...) SE1A/20-PKZ2(...)Article no. 1) Article no. 1) Article no. 1) Article no. 1)Standard voltage see price list see price list see price list see price list24V 50Hz 026609 – – –48V 50Hz 062651 056383 – –240V 50Hz 001882 057048 058716 05871724V 60Hz 062501 – – –110V 50Hz,063694 063701 063709 063716120V 60Hz190V 50Hz,063695 – 063710 063717220V 60Hz220V 50Hz,063699 063706 – –240V 60Hz230V 50Hz,063696 063703 063711 063718240V 60Hz400V 50Hz,063697 – 063712 063719440V 60Hz24V 50/60Hz 062500 – 058720 058721110V 50/60Hz – – 058696 –230V 50/60Hz 065103 056395 058712 058713DC S-G-PKZ2(...) SE1A-G-10-PKZ2(...)Article no. 1) Article no. 1)Standard voltage see price list see price list24V DC 070921 058856Notes1) The article no. is formed from the combination of part no. and actuating voltage.Devices with dual-voltage coils are to be ordered under a single order number.2) With non-standard voltages the required actuating voltage from the defined range (...–...V) must be stated.For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008PKZM0, PKZM4 and PKZ2 in 1 and 2 pole <strong>circuit</strong>sfoe DC and AC1 3 5I > I > I >2 4 61 3 5I > I > I >2 4 6Protection of PVC insulated cables against thermal overload with short-<strong>circuit</strong>sEngineering<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZ, PKZMThe table indicates which minimum cable cross-sections are protected by PKZ(M) motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>up to their rated conditional short-<strong>circuit</strong> current I q .Min. cross-section protectedDeviceMin. cross-section protectedDevice380 – 415 V, 50 Hz, Cu mm 2 Part no.380 – 415 V, 50 Hz, Cu mm 2 Part no.4 2,5 1,5 1 0,754 2,5 1,5 1 0,75PKZM0-0.16PKZ2/ZM-0,68/47PKZM01, PKZM0, PKZM4, PKZ2motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>...PKZM0-6.3PKZM0-10PKZM0-12PKZM0-16PKZM0-20PKZM0-25PKZM0-32PKZM4-16PKZM4-25PKZM4-32PKZM4-40PKZM4-50PKZM4-58PKZM4-63...PKZ2/ZM-2.4PKZ2/ZM-4PKZ2/ZM-6PKZ2/ZM-10PKZ2/ZM-16PKZ2/ZM-25PKZ2/ZM-32PKZ2/ZM-40Fuseless installation with PKZ(M), back-up-protection diagramsBack-upprotectionrangewith CL-PKZ 0Ratedshort-<strong>circuit</strong>breakingcapacityrangePKZM0PKZM0415 V ACI cnI ccInherently short-<strong>circuit</strong> proof I cc rms [kA]10050302016106PKZM0Inherentlyshort-<strong>circuit</strong>-proofPKZM0-...+ CL-PKZ0PKZM0-...Ratedcurrent I n [A]0.16... 10 16 20 25Back-upprotectionrangewith CL-PKZ2or S-PKZ2Ratedshort<strong>circuit</strong>breakingcapacityrangePKZ2/ZMPKZ2at415 V ACIcnIccInherently short-<strong>circuit</strong> proof I cc rms [kA]1005030201064PKZ2Inherentlyshort-<strong>circuit</strong>-proofPKZ2/ZM-.../SPKZ2/ZM-...+CLPKZ2/ZM-...Ratedcurrent I n [A]0.6... ...16 25 32 40Back-upprotectionrangewith CL-PKZ 0Ratedshort-<strong>circuit</strong>breakingcapacityrangePKZM4PKZM4415 V ACI cnI ccInherently short-<strong>circuit</strong> proof I cc rms [kA]10050302016106Inherentlyshort-<strong>circuit</strong>-proofPKZM4-... +CL-PKZ0PKZM4-...Ratedcurrent16... 25 32 40 50 63I n [A]


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/48EngineeringCharacteristic curvesPKZMPKZM0-...T tripping characteristics (not for PKM0-...), PKZM01<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netPKZM01, PKZM0, PKZM4, PKZ2motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Milliseconds SecondsMinutes2 h20105214020105212005020PKZM0-...,PKZM01PKZM0...-TMilliseconds SecondsMinutes2 h20105214020105212005020PKZM4-...55221.5 2 3 4 6 8 10 15 20 301.5 2 3 4 6 8 10 15 20 30x Rated operational currentx Rated operational currentLet-through characteristics, motor-<strong>protective</strong> <strong>circuit</strong>-breaker, transformer-<strong>protective</strong> <strong>circuit</strong>-breaker, <strong>circuit</strong>-breaker for starter combinationsx D 10PKZM0-....[kA] 8 PKZM01-....6PKM0-....43210.80.60.40.30.20.10.080.060.040.030.020.0150.012 · I ccU e = 400 V1 1.5 2 3 4 6 8 10 15 20 30 40 60 80100I cc rms [kA]32 A25 20 A16 A10 A/12 A6.3 A4.0 A2.5 A1.6 A1 A0.63 A0.4 A0.25 AZy[A 2 s]10 5 PKZM018PKZM0-.... 32 A6PKM0-.... 25 20 A16 4310 A/12 A26.3 A1.510 4864.0 A4321.510 3 86431 st half-wave2.5 A1.6 A2U e = 400 V1.51021.0 A1 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100I cc rms [kA]<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker let-through characteristicsÎD[kA]100PKZM4Zy10 6[A 2 s]PKZM42 · I cc10 51 st half-wave63/58 A50/40/32 A25 A16 A1063/58 A50/40/32 A25 A16 A10 410 3 U e = 400 V11U e = 400 V10 100I cc rms [kA]10 2 1 10 100I cc rms [kA]


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008Circuit-breaker switching capacity from serial no. 04EngineeringSwitching capacityPKZM08/49Rated uninterrupted current I uRated conditional short-<strong>circuit</strong> current I q IEC/EN 60947-4-1Rated ultimate short-<strong>circuit</strong> breaking capacity I cu ⎫⎬ IEC/EN 60947-2Rated service short-<strong>circuit</strong> breaking capacity I cs ⎭230 V 400 V 440 V 500 V 690 VIu I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I csA kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1)PKZM0, PKZM0...-T, PKM0 with classification type “1” and “2”0,16 – 1 150 150 150 N 150 150 150 N N N N1,6 150 150 150 N 150 150 150 N N N N2,5 150 150 150 N 150 150 150 N N N 5 5 5 504 150 150 150 N 150 150 150 N N N 3 3 3 506,3 150 150 150 N 150 150 150 N N 42 42 6 50 3 3 2 5010 150 150 150 N 150 150 150 N 42 42 10 50 42 42 6 50 3 3 2 5012 50 50 10 50 50 50 10 50 15 15 10 50 15 15 6 50 3 3 2 5016 50 50 10 50 50 50 10 50 15 15 10 50 15 15 6 50 3 3 2 5020 50 50 10 50 50 50 10 50 10 10 10 50 6 6 6 50 3 3 2 5025 50 50 10 50 50 50 10 50 10 10 10 50 6 6 6 50 3 3 2 5032 50 50 10 50 50 50 10 50 10 10 10 50 6 6 6 50 3 3 2 50PKZM01, PKZM0, PKZM4motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM0 (PKZM0...-T, PKM0) + CL-PKZ00,16 – 1 N N N N 20 N1,6 N N N N 20 N2,5 N N N N 20 20 20 N4 N N N N 20 20 20 N6,3 N N N 50 N 20 20 20 N10 N N N 20 N 20 20 20 N12 N N N 20 N 5 5 2,5 N16 N N N 20 N 5 5 2,5 N20 N N N 10 10 10 N 5 5 2,5 N25 N N N 10 10 10 N 5 5 2,5 N32 N N N 10 10 10 N 5 5 2,5 NPKZM0 (PKZM0...-T, PKM0) + 2 CL-PKZ00,16 – 1 N N N N 20 N1,6 N N N N 20 N2,5 N N N N 40 40 20 N4 N N N N 40 40 20 N6,3 N N N 50 N 20 20 20 N10 N N N 40 N 20 20 20 N12 N N N 40 N 10 10 2,5 N16 N N N 40 N 10 10 2,5 N20 N N N 20 20 20 N 10 10 2,5 N25 N N N 20 20 20 N 10 10 2,5 N32 N N N 20 20 20 N 10 10 2,5 NNotesNo upstream <strong>protective</strong> devicerequired, as it is the autoprotectedrange (100/150 kA)1) Necessary back-up fuse when the short-<strong>circuit</strong> currentexceeds the rated conditional short-<strong>circuit</strong> current of the device (I cc I q ).NNot required


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/50EngineeringSwitching capacityPKZM01, PKZM4Circuit-breaker switching capacity<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netPKZM01, PKZM0, PKZM4motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Rated uninterrupted current I uRated conditional short-<strong>circuit</strong> current I q IEC/EN 60947-4-1Rated ultimate short-<strong>circuit</strong> breaking capacity I cu ⎫⎬ IEC/EN 60947-2Rated service short-<strong>circuit</strong> breaking capacity I cs ⎭230 V 400 V 440 V 500 V 690 VIu I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I csA kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1) kA kA kA A 1)PKZM01 with classification type “1” and “2”0.16 – 1 50 50 50 50 50 50 50 50 50 50 50 501.6 50 50 50 50 50 50 50 50 50 50 50 502.5 50 50 50 50 50 50 50 50 50 50 50 504 50 50 50 50 50 50 50 50 50 50 50 506.3 50 50 50 50 50 50 50 50 50 50 50 5010 50 50 50 50 50 50 50 50 42 42 10 5012 50 50 10 50 50 50 10 50 15 15 10 5016 50 50 10 50 50 50 10 50 15 15 10 50PKZM4 with classification type “1” and “2”16 150 150 25 N 150 150 25 N 45 45 25 100 15 15 100 8 8 2.5 10025 150 150 25 N 150 150 25 N 45 45 25 100 15 15 100 8 8 2.5 10032 50 50 25 100 50 50 25 100 45 45 25 100 15 15 100 5 5 2.5 10040 50 50 25 100 50 50 25 100 45 45 25 100 15 15 100 5 5 2.5 10050 50 50 25 100 50 50 25 100 45 45 25 100 15 15 100 5 5 2.5 10058 50 50 25 160 50 50 25 160 45 45 25 160 15 15 160 5 5 2.5 16063 50 50 25 160 50 50 25 160 45 45 25 160 15 15 160 5 5 2.5 160NotesNo upstream<strong>protective</strong> device necessary,as it is the auto-protected range(150 kA)1) Fuse (A gG/gL) for enhancing theswitching capacity of the motor<strong>protective</strong><strong>circuit</strong>-breaker to100 kANNot necessary


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008Tripping characteristic, motor-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> (high-capacity)compact startersMilliseconds SecondsMinutes2h20105214020105212005020PKZ2/ZM-...PKZ2/ZM-.../SPKZ2/ZM-.../SE1AEngineeringCharacteristic curvesPKZ2Tripping characteristics, cable and conductor protectionMilliseconds SecondsMinutes2h20105214020105212005020PKZ2/ZM-...-88/51PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker5521,5 2 3 4 6 8 10 15 20 30x Rated operational currentLet-through characteristics, <strong>circuit</strong>-breaker, compact starters21,5 2 3 4 6 8 10 15 20 30x Rated operational currentx D[kA]1008060403020PKZ2/ZM-...(-8)PKZ2/ZM-...(-8)/SE1A2 · I ccZ i 2 dt 10 62PKZ2/ZM-...(-8)[A s] 8PKZ2/ZM-...(-8)/SE1A643232/40 A25 A1.51 st half-wave1510864332/40 A25 A16 A10 A6 A10 5864321.516 A10 A6 A21.511U e = 400 V1.5 2 3 4 6 8 10 15 20 30 40 60 80 100I cc rms [kA]10 486U e = 400 V41 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100I cc rms [kA]High-capacity compact starter and <strong>circuit</strong>-breaker + CL current limiter let-through characteristicsÎD[kA]100806040302015108643PKZ2/ZM-...(-8)/SPKZ2/ZM-...(-8)/S-GPKZ2/ZM-...(-8)+CLPKZ2/ZM-.../S-SP2 · I cc32/40 A25 A16 A10 A6 AZ y6102[A s] 864321,5510864321.51 st half-wavePKZ2/ZM-...(-8)/SPKZ2/ZM-...(-8)/S-GPKZ2/ZM-...(-8)+CLPKZ2/ZM-.../S-SP40 A32 A25 A16 A10 A6 A21.511e = 400 V1.5 2 3 4 6 8 10 15 20 30 40 60 80 100UI cc rms[kA]41086U e = 400 V41 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100I cc rms [kA]


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker8/52EngineeringCharacteristic curvesPKZ2S-PKZ2 high-capacity contact module, SE1A-PKZ2 contact moduleNormal switching dutykWRated output of three-phasemotors 50...60 HzAC-3/400V18.515117.55.5432.21.51.10.750.550.370.25ARated operationalcurrent 50...60 Hz3528.522.115.411.48.86.85.23.62.651.86Normal switching dutyS(E1A)-PKZ21.421.050.810.1 0.2 0.4 0.6 0.8 1 2 3 4 5 6 8 10Component lifespan (millions of operations)<strong>Moeller</strong> HPL0211-2007/2008Normal AC induction motorOperatingcharacteristics:Typical applications:Starting:Stopping:compressorspumpsfansvalves<strong>Electric</strong>al characteristics: Starting:Stopping:http://catalog.moeller.netfrom restduring runningliftsescalatorsconveyorsbucket-elevatorsmixersagitatorscentrifugesairconditioningsystemsGeneral drives for manufacturing and processingmachinesup to6 X rated motor current1 X rated motor currentUtilization category:100 % AC-3Extreme switching dutieskWRated output of three-phasemotors 50...60 Hz3528.522.115.411.48.86.85.23.62.651.861.421.050.81Light switching dutyBreaking currentAC-4/400V18.515117.55.5432.21.51.10.750.550.370.25ARated operationalcurrent 50...60 HzAC-1/400VA403528,522,115,411,48,86,85,23,62,651,861,421,050,81Extreme switching dutyS(E1A)-PKZ20.01 0.02 0.03 0.04 0.06 0.1 0.2 0.3 0.4 0.6 1 2 3 4 5Component lifespan (millions of operations)Non-motor loads, 3-poleS(E1A)-PKZ20,1 0,2 0,4 0,6 0,8 1 2 3 4 5 6 8 10Component lifespan (millions of operations)Normal AC induction motorOperatingInching, plugging, reversingcharacteristics:Typical applications: printing machineswire-drawing machinescentrifugesSpecial drives on manufacturing and processingmachines<strong>Electric</strong>al characteristics: Starting:Stopping:Utilization category:Non-motor loadsOperatingcharacteristics:Typical applications:100 % AC-46 X rated motor current6 X rated motor currentNon inductive and slightly inductive loads<strong>Electric</strong>alheaters<strong>Electric</strong>al characteristics: Starting:Stopping:Utilization category:100 % AC-1up to1.5 X rated current1 X rated currentDetermination of the maximum operating frequency dependant on the rating and utilization category (recommended values)for (high capacity) contact modulesP N = max. motor rating (kW) ops/h= max. operations per hourOps./h90007000600050004000300020001500AC-31000800600500400300AC-42001501000 10 20 30 40 50 60 70 80 90 100%(kW) P N


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker switching capacity and (high-capacity) compact starterEngineeringSwitching capacityRated uninterrupted current I uRated conditional short-<strong>circuit</strong> current I q IEC/EN 60 947-4-1Rated ultimate short-<strong>circuit</strong> breaking capacity I cu ⎫IEC/EN 60 947-2Rated service short-<strong>circuit</strong> breaking capacity I⎬cs ⎭1) 1) 1) 1) 1)230 V 400 V 440 V 500 V 690 VIu I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I cs I q I cu I csA kA kA kA A kA kA kA A kA kA kA A kA kA kA A kA kA kA APKZ2/ZM with classification type “1” and “2”0,16 – 1,6 N N N N N2,4 N N N N N4 N N N N 4,5 4,5 2,5 636 N N N N 4,5 4,5 2,5 8010 30 N 30 N 10 10 5 80 7 7 3,5 80 4,5 4,5 2,5 8016 30 N 30 N 10 10 5 100 7 7 3,5 100 4,5 4,5 2,5 10025 30 30 7,5 160 30 30 7,5 160 10 10 5 125 7 7 3,5 125 4,5 4,5 2,5 12532 30 30 7,5 160 30 30 7,5 160 10 10 5 160 7 7 3,5 160 4,5 4,5 2,5 16040 30 30 7,5 160 30 30 7,5 160 10 10 5 160 7 7 3,5 160 4,5 4,5 2,5 160PKZ2/ZM + CL-PKZ2 with classification type “1” and “2”0,16 – 1,6 N N N N N2,4 N N N N N4 N N N N 10 4,5 2,5 N6 N N N N 10 4,5 2,5 N10 30 N 30 N 5 N 3,5 N 10 4,5 2,5 N16 30 N 30 N 5 N 3,5 N 10 4,5 2,5 N25 7,5 N 7,5 N 5 N 3,5 N 10 4,5 2,5 N32 7,5 N 7,5 N 5 N 3,5 N 10 4,5 2,5 N40 7,5 N 7,5 N 5 N 3,5 N 10 4,5 2,5 NPKZ2/ZM(R)-.../SE1A(-G)... with classification type “1”0,16 – 1,6 N N N N N N N N N N N N N N N2,4 N N N N N N N N N N N N N N N4 N N N N N N N N N N N N 4,5 N N 636 N N N N N N N N N N N N 4,5 N N 8010 N N N N N N 10 N N 80 7 N N 80 4,5 N N 8016 N N N N N N 10 N N 100 7 N N 100 4,5 N N 10025 30 N N 160 30 N N 160 10 N N 125 7 N N 125 4,5 N N 12532 30 N N 160 30 N N 160 10 N N 160 7 N N 160 4,5 N N 16040 30 N N 160 30 N N 160 10 N N 160 7 N N 160 4,5 N N 160PKZ2/ZM-.../S(-G) with classification type “1” and “2”0,6 – 2,4 N N N N N N N N N N4 – 6 N N N N N N N N 10 N N 8010 – 16 N N N N N N N N 10 N N 10025 – 40 N N N N N N N N 10 N N 160PKZ2/ZM-..-8 and PKZ2/ZM-..-8/SE1A(-G)0,16 – 1,6 N N N N N N N N N N2,4 N N N N N N N N N N4 N N N N N N N N N 4,5 2,5 636 N N N N N N N N N 4,5 2,5 8010 N 30 N N 30 N N 10 5 80 N 7 3,5 80 N 4,5 2,5 8016 N 30 N N 30 N N 10 5 100 N 7 3,5 100 N 4,5 2,5 10025 N 30 7,5 160 N 30 7,5 160 N 10 5 125 N 7 3,5 125 N 4,5 2,5 12532 N 30 7,5 160 N 30 7,5 160 N 10 5 160 N 7 3,5 160 N 4,5 2,5 16040 N 30 7,5 160 N 30 7,5 160 N 10 5 160 N 7 3,5 160 N 4,5 2,5 160PKZ2/ZM-...-8/S(-G)0,6 – 2,4 N N N N N N N N N N4 – 6 N N N N N N N N N 10 5 8010 – 16 N N N N N N N N N 10 5 10025 – 40 N N N N N N N N N 10 5 160PK228/53PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerNotesNo upstream <strong>protective</strong> devicerequired,as it is the autoprotectedrange (100 kA)1) Fuse (A gG/gL) for enhancing the switchingcapacity of the motor-<strong>protective</strong> <strong>circuit</strong>-breakerto 100 kANNot necessary


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/54Technical Data<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Technical Data<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>8/55PKZM<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.nethttp://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008PKZM<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4PKZM01... PKZM0-... PKM0-... PKZM0-...-T PKZM4GeneralStandards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14Climatic proofing Damp heat, constant, to IEC 60068-2-78Damp heat, cyclic, to IEC 60068-2-30Damp heat, constant, to IEC 60068-2-78Damp heat, cyclic, to IEC 60068-2-30Ambient temperature Storage °C –25…80 –25…80 –25…80 –25…80 –25…70Open °C –25…55 –25…55 –25…55 25…55 –25…55Enclosed °C –25…40 –25…40 –25…40 –25…40 –25…40Mounting position90˚90˚90˚90˚90˚90˚90˚90˚<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Direction of incoming supply As required As required As required As required As requiredDegree of protection Device IP 20 IP 20 IP 20 IP 20 IP 20Terminations IP00 IP00 IP00 IP00 IP00Protection against direct contact Finger and back-of-hand proof Finger and back-of-hand proofMechanical shock resistance half-sinusoidal shock 10 ms to IECg 25 25 25 25 1560068-2-27Altitude m 2000 2000 2000 2000 2000Terminal capacity screwterminalsSolid mm 2 1 x (1 – 6)2 x (1 – 6)Flexible with ferrule to DIN 46228 mm 2 1 x (1 – 6)2 x (1 – 6)1 x (1 – 6)2 x (1 – 6)1 x (1 – 6)2 x (1 – 6)Solid or stranded AWG 18 – 10 18 – 10 18 – 10 18 – 10 14 – 2Terminal capacity springloaded terminalsTerminal capacity screwterminalsSolid mm 2 1 x (1…2.5)2 x (1…2.5)Flexible with ferrule to DIN 46228 mm 2 1 x (1…2.5)2 x (1…2.5)1 x (1 – 6)2 x (1 – 6)1 x (1 – 6)2 x (1 – 6)1 x (1…2.5)2 x (1…2.5)1 x (1…2.5)2 x (1…2.5)Solid or stranded AWG 18…14 18…14Specified tightening torque for terminal screwsMain cable Nm 1.7 1.7 1.7 1.7 3Control <strong>circuit</strong> cables Nm 1 1 1 1 11 x (1 – 6)2 x (1 – 6)1 x (1 – 6)2 x (1 – 6)1 x (1 – 50)2 x (1 – 35)1 x (1 – 35)2 x (1 – 35)Main conducting pathsRated impulse withstand voltage U imp V AC 6000 6000 6000 6000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3Rated operational voltage U e V AC 690 690 690 690 690Rated uninterrupted current = rated operational current I u = I e A 16 or current setting of theovercurrent release32 or current setting of theovercurrent release32 or current setting of the overcurrentrelease25 or current setting of the overcurrentreleaseRated frequency Hz 40 – 60 40 – 60 40 – 60 40 – 60 40 – 60Current heat loss (3 pole at operating temperature) W 6 6 6 6 22Lifespan, mechanical Operations x 10 6 0.05 0.1 0.1 0.1 0.03Lifespan, electrical (AC-3 at 400 V) Operations x 10 6 0.05 0.1 0.1 0.1 0.03Maximum operating frequency Operations/h Ops/h 25 40 40 40 40Short-<strong>circuit</strong> ratingAC a Engineering a Engineering a Engineering a Engineering a EngineeringDC kA 60 60 (up to PKZM0-16)40 (PKZM0-20 to PKZM0-32)60 (up to PKM0-16)40 (PKM0-20 to PKM0-32)60 (up to PKZM0-16)40 (PKZM0-20 to PKZM0-32)<strong>Motor</strong> switching capacity AC-3 (up to 690 V) A 16 32 32 25 6565 open63 enclosed60DC-5 (up to 250 V) A 16 (3 contacts in series) 25 (3 contacts in series) 25 (3 contacts in series) 25 (3 contacts in series) 63 (3 contacts in series)ReleasesTemperature compensationto IEC/EN 60947, VDE 0660 °C –5…40 –5…40 –5…40 –5…40 –5…40Operating range °C –25…55 –25…55 –25…55 –25…55 –25…55Temperature compensation residual error for T > 40 °C %/K F 0.25 F 0.25 F 0.25 F 0.25 F 0.25Setting range of overload releases x I u 0.6 – 1 0.6 – 1 – 0.6 – 1 0.6 – 1Short-<strong>circuit</strong> release fixed x I u 14 14 14 20 14Short-<strong>circuit</strong> release tolerance % g 20 g 20 g 20 g 20 g 20Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 IEC/EN 60947-1-1, VDE 0660 Part 102


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/56Technical DataAuxiliary contacts, voltage releasesNHI…PKZ, AGM, U-PKZ, A-PKZ,<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4NHI...PKZ0 NHI-E-...PKZ0 VHI...PKZ0 AGM tripindicationAuxiliary contactsRated impulse withstand voltage U imp V AC 6000 4000 4000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3Rated operational voltage U e V AC 500 440 440 500U e V DC 250 250 250 250Safe isolation to VDE 0106 Part 101 and Part 101/A1Between auxiliary contacts and main contacts V AC 690 690 690 690Rated operational currentAC–15220 – 240 V I e A 3.5 1 1 3.5380 – 415 V I e A 2 – – 2440 – 500 V I e A 1 – – 1DC-13 L/R – 100 ms24 V I e A 2 2 2 260 V I e A 1.5 – – 1.5110 V I e A 1 – – 1220 V I e A 0.25 – – 0.25LifespanLifespan, mechanical Operations x 10 6 0.1 0.1 0.1 0.01Lifespan, electrical Operations x 10 6 0.05 0.1 0.1 0.005Control <strong>circuit</strong> reliability (at U e = 24 V DC, U min = 17 V, I Failure rate l < 10 -8 < 1 failure at 1 x 10 8 operationsmin= 5.4 mA)Interlocked opposing contacts to ZH 1/457 Yes – – –Short-<strong>circuit</strong> rating without weldingFuseless FAZ-B4/1-HI – – FAZ-B4/1-HIFuse A gG/gL 10 10 10 10Terminal capacitiesSolid or flexible conductor with ferrule mm 2 0.75 – 2.5 0.75 – 1.5 0.75 – 1.5 0.75 – 2.5Solid or stranded AWG 18 – 14 18 – 16 18 – 16 18 – 14Undervoltage releaseTerminal capacitiesU-PKZ...Solid or flexible conductor withmm 2 2 x (0.75 – 2.5)ferruleSolid or stranded AWG 2 x (18 – 14)Main conducting pathsRated operating voltage U e V AC 42 – 480Rated operating voltage U e V DC 24 – 250Pick-up voltage x U s 0.85 – 1.1Drop-out voltage x U s 0.7 – 0.35Power consumption Pick-up AC Pick-up VA 5Sealing AC Sealing VA 3Shunt releaseTerminal capacitiesA-PKZ...Solid or flexible conductor withmm 2 2 x (0.75 – 2.5)ferruleSolid or stranded AWG 2 x (18 – 14)Main conducting pathsRated operating voltage U e V AC 42 – 480Rated operating voltage U e V DC 24 – 250Operating range AC x U s 0.7…1.1DC x U s 0.7…1.1Power consumptionAC Pick-up AC Pick-up VA 5Sealing AC Sealing VA 3DC Pick-up DC Pick-up W 3Sealing DC Sealing W 3


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.netGeneralStandards<strong>Moeller</strong> HPL0211-2007/2008Technical Data<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZ2/ZM-...(8)PKZ2/ZM-...(8)/SE...PKZ2/ZM-...(8)/S(+CL)S(EA)...IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14, GL, LR, DNV,PRS, BV, RINA, RS, EZU, MEEIClimatic proofing Damp heat, constant, to IEC 60068-2-78;Cyclic to IEC 60068-2-30Ambient temperature Storage °C -25…70 -25…70 -25…70 -25…70Open °C –25…60 –25…60 –25…60 –25…60Enclosed °C –25…40 –25…40 –25…40 –25…40Mounting positionPKZ2PKZ2/.../SPKZ2/.../SPKZ2/.../+CL90°PKZ230°8/57PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker90°90°PKZ290° 90°PKZ2{ PKZ2/.../+CLSCLSCLDirection of incoming supplyAs requiredProtection typeIP00Mechanical shock resistanceHalf-sinusoidal shock 20 ms to IEC 60068-2-27 g 30 8 8 8Altitude m 2000Terminal capacities Solid or stranded mm 2 1 x (1 – 16)2 x (1 – 6)Flexible with ferrule mm 2 1 x (1.5 – 10)2 x (1.5 – 6)Solid or stranded AWG 14 – 6 14 – 6 14 – 6 14 – 6Specified tightening torque Main cable Nm 1.8 1.8 1.8 1.8for terminal screws Control <strong>circuit</strong> cables Nm 1 1 1 1Main conducting pathsRated impulse withstand voltage U imp V AC 6000 6000 6000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3Rated operational voltage U e V AC 690 690 690 690Rated uninterrupted current = rated operational current I u = I e A 40 40 40 40Rated frequency Hz 50 – 60 50 – 60 50 – 60 50 – 60Current heat loss (3-pole at operating temperature) W 14 23 23 9Lifespan, mechanical Operations x 10 6 0.1 5 5 5Lifespan, electrical 100 % AC-3 Operations x 10 6 0.05 1 1 1AC-4 Operations x 10 6 – 0.03 0.03 0.03Maximum operating frequency Operations/h Ops/h 60 a Projektieren Kennlinien<strong>Motor</strong> switching capacity AC-3 (up to 690 V) A 40 40 40 40DC-5 up to 250 V A 40 40 40 40DC applicationRated short-<strong>circuit</strong> I cn (250 V DC), L/R = 15 ms kA 30 30 50breaking capacity I cn I cn (125 V DC), L/R = 15 ms kA 50 50 65Operating times under short<strong>circuit</strong>conditionsMinimum command time ms Approx. 2 Approx. 2 Approx. 2 Approx.Opening delay ms Approx. 0.5 Approx. 0.5 Approx. 0.5 Approx.Total opening delay ms 6 6 4Notes With dual-frequency coil 50/60 Hz, the mechanical lifespan reduces by 30%ZM-...-PKZ2 ZMR-...-PKZ2 ZM-...-8-PKZ2(4)ReleasesFunction <strong>Motor</strong> protection <strong>Motor</strong> protection System protectionTemperature compensationto IEC/EN 60947, VDE 0660 °C –5…40 –5…40 –5…40Operating range °C –25…60 –25…60 –25…60Temperature compensation residual error for T > 40 °C %/K F 0.25 F 0.25 F 0.25Short-<strong>circuit</strong> release tolerance % g 20 g 20 g 20Setting range of overload releases x I u 0.6 – 1 0.6 – 1 0.6 – 1Short-<strong>circuit</strong> releases x I u 8.5 – 14 8.5 – 14 5 – 8.5


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker8/58Technical Data(High-capacity) contact module, current limiterSE…x…PKZ, CL-PKZ<strong>Moeller</strong> HPL0211-2007/2008S(EA)...(High-capacity) contact moduleOperating delays Closing delay ms 9 – 30Opening delay ms 4 – 12Duty factor % DF 100Rated making capacity c = 0.45 A 400Rated breaking capacity c = 0.45 A 400Magnet systemsAC operationOperating range Pick-up voltage x U s 0.85 – 1.1Drop-out voltage x U s 0.4 – 0.6Power consumption Pick-up AC Pick-up VA 190Sealing AC Sealing VA 13DC operationRated control voltage U s V DC 24Operating range Pick-up voltage x U s 0.85 – 1.1Power consumption Pick-up DC Pick-up VA 150Sealing DC Sealing VA 2.7Current consumption Pick-up A 6.3Sealing mA 113Rated operational current, open, enclosedAC-1 230 V I e A 40400 V I e A 40440 V I e A 40500 V I e A 40690 V I e A 40AC–-3 230 V I e A 40400 V I e A 40440 V I e A 40500 V I e A 40690 V I e A 40AC-4 230 V e I A 30400 V I e A 30440 V I e A 30500 V I e A 28690 V I e A 25http://catalog.moeller.netCL-PKZ2Current limiterRated making capacity c = 0.45 A 400Rated breaking capacity c = 0.45 A 400AC-1 duty Conventional thermal current I th A 40


Technical DataAuxiliary contacts8/59http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008NHI…PKZNHI11(S)-PKZ2 NHI22(S)-PKZ2 NHI2-11S-PKZ2 AGM2-11-PKZ2Auxiliary contactsRated impulse withstand voltage U imp V AC 6000 6000 6000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3Rated operational voltage U e V AC 500 500 500 500Rated operational currentAC–15 230 – 240 V I e A 6 6 6 5400 – 415 V I e A 3 1.5 3 3440 V I e A 1.5 1.5 1.5 1.5500 V I e A 1.5 1.5 1.5 1.5Lifespan, mechanical Operations x 10 6 0.1 0.1 5 0.01Lifespan, electrical Operations x 10 6 0.05 0.05 1 0.005PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerControl <strong>circuit</strong> reliability (at U e = 24 V DC, U min =17 V, I min = 10 mA)Failure rate l Control <strong>circuit</strong> reliability through the entire mechanical lifespanInterlocked opposing contacts to ZH 1/457 – – Yes YesShort-<strong>circuit</strong> rating without weldingFuseless240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6Fuse A gG/gL 10 10 10 10Terminal capacitiesSolid or flexible conductorwith ferrulemm 2 1 x (0.75 – 2.5)2 x (0.75 – 2.5)Solid or stranded AWG 1 x (22 – 14)2 x (22 – 14)Safe isolation to VDE 0106 Part 101 and Part 101/A11 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (22 – 14)2 x (22 – 14)Between auxiliary contacts and main contacts V AC 690 690 5001 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (22 – 14)2 x (22 – 14)240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,61 x (0.75 – 2.5)2 x (0.75 – 2.5)22 – 14HI...-S-PKZ2 HI11-S/EZ-PKZ2 ZMR-...(95 – 96) ZMR-...(97 – 98)Auxiliary contactsRated impulse withstand voltage U imp V AC 6000 6000 6000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3Rated operational voltage U e V AC 500 500 500 500Rated operational currentAC–15 230 – 240 V I e A 6 6 1.5 1.5400 – 415 V I e A 1.5 3 0.7 0.5440 V I e A 1.5 1.5 0.5 0.3500 V I e A 1.5 1.5 0.5 0.3Lifespan, mechanical Operations x 10 6 5 5 0.01 0.01Lifespan, electrical Operations x 10 6 1 1 0.005 0.005Control <strong>circuit</strong> reliability (at U e = 24 V DC, U min =17 V, I min = 10 mA)Failure rate l Control <strong>circuit</strong> reliability through the entire mechanical lifespanInterlocked opposing contacts to ZH 1/457 – – – –Short-<strong>circuit</strong> rating without weldingFuseless240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6240 V: PKZM0-6,3415 V: PKZM0-4500 V: PKZM0-1,6– –Fuse A gG/gL 10 10 10 10Terminal capacitiesSolid or flexible conductor withferrulemm 2 1 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (0.75 – 2.5)2 x (0.75 – 2.5)Solid or stranded AWG 22 – 14 22 – 14 22 – 14 22 – 14Safe isolation to VDE 0106 Part 101 and Part 101/A1Between auxiliary contacts and main contacts V AC 500 500 – –1 x (0.75 – 2.5)2 x (0.75 – 2.5)For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


8/60Technical DataVoltage releasePKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerU-PKZ, A-PKZ<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.netU-PKZ2... U-HI20-PKZ2... UVHI-PKZ2Undervoltage releaseRated impulse withstand voltage U imp V AC 6000 6000 6000Overvoltage category/pollution degree III/3 III/3 III/3Terminal capacitiesSolid or flexible conductor with ferrule mm 2 1 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (0.75 – 2.5)2 x (0.75 – 2.5)1 x (0.75 – 2.5)2 x (0.75 – 2.5)Solid or stranded AWG 22 – 14 22 – 14 22 – 14Rated operating voltage U e V AC 24 – 600 24 – 600 24 – 600Rated operating voltage U e V DC 24 – 125 24 – 125 24 – 125Drop-out voltage x U s V 0.7 – 0.35 0.7 – 0.35 0.7 – 0.35Power consumptionACPick-up AC Pick-up VA 5 5 5Sealing AC Sealing VA 3 3 3DCPick-up DC Pick-up W 3 3 3Sealing DC Sealing W 3 3 3Off-delay ms – – 200Rated operational currentAC–15230 V I e A – 6 6400 V I e A – 3 3440 V I e A – 1.5 1.5A-PKZ2...Shunt releaseRated impulse withstand voltage U imp V AC 6000Overvoltage category/pollution degreeIII/3Terminal capacitiesSolid or flexible conductor with ferrule mm 2 1 x (0.75 – 2.5)2 x (0.75 – 2.5)Solid or stranded AWG 22 – 14Rated operating voltage U e V AC 24 – 600Rated operating voltage U e V DC 24 – 250Operating rangeAlternating voltage x U s 0.7 – 1.1DC x U s 0.7 – 1.1Power consumptionACPick-up AC Pick-up VA 5Sealing AC Sealing VA 3DCPick-up DC Pick-up W 3Sealing DC Sealing W 0.3BK...-PKZ2, B3.1/...-PKZ2Incoming terminal and three-phase currentRated impulse withstand voltage U imp V AC 6000Overvoltage category/pollution degreeIII/3Rated operational voltage U e V AC 690Rated uninterrupted current I u A 120For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


Technical DataR...-PKZ2 remote operator8/61http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008RE-PKZ2RS-PKZ2Remote operatorRated impulse withstand voltage U imp V AC 6000 6000Overvoltage category/pollution degree III/3 III/3Rated operating voltage U e V AC 380 – 440 380 – 440Rated operating voltage U e V DC 24 – 240 24 – 240Safe isolation to VDE 0106 Part 101 and Part 101 A1 betweenV AC 500 500auxiliary contacts and main contactsRequired short-time rating (30 ms) VA/W 700 700Control transformer short-time rating VA 1000 1000Short<strong>circuit</strong> voltage % 4.4 4.4Closing delay ms 30 30Opening delay ms 30 30Reset time to Off ms 30 30Maximum operating frequency Ops/h 60 60Operating range Alternating voltage x U s 0.85 – 1.1 0.85 – 1.1DC x U s 0.85 – 1 0.85 – 1Lifespan, electrical Operations x 10 6 0.05 0.05Integral auxiliary contacts (make contact 33/34 Hand/Autoindication)Conventional free air thermal current th I th A 1.5 1.5Rated operational currentAC–-14 230/240 V I e A 1.5 1.5400/415 V I e A 1 1440 V I e A 0.5 0.5Terminal capacitiesSolid or flexible conductor with ferrule mm 2 1 x (0.75 – 2.5)2 x (0.75 – 2.5)RE-PKZ, RS-PKZSolid or stranded AWG 22 – 14 22 – 141 x (0.75 – 2.5)2 x (0.75 – 2.5)PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerBK...-PKZ2, B3.1/...-PKZ2Incoming terminal and three-phase currentRated impulse withstand voltage U imp V AC 6000Overvoltage category/pollution degreeIII/3Rated operational voltage U e V AC 690Rated uninterrupted current I u A 120For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM48/62Dimensions<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01...4545935.5447485<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>Transformer-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong><strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker with standardauxiliary contactPKZM0-...(+NHI-E-...-PKZ0)PKZM0-...-T(+NHI-E-...-PKZ0)PKM0-...(+NHI-E-...-PKZ0)70<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> with lockable rotary handlesPKZM0-...+AK-PKZ0AK-PKZ 09355454.59345AK-PKZ 02545NHI-E-..-PKZ0506876NHI-E-..-PKZ045508894Current limitersCL-PKZ...4528<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> with early-make auxiliary contactsPKZM0-...+VHI-...-PKZ080a907393934555VHI...-PKZ07.54449.57.570VHI...-PKZ045506886Standard auxiliary contacts Trip-indicating auxiliary contacts Shunt releasesUndervoltage releasesNHI...-PKZ0 AGM2...-PKZ0 A-PKZ0...U-PKZ0...3645903645903645909 26689 266818 4968


DimensionsAccessories8/63http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008PKZ0Three-phase commoning linksThree-phase commoning linksB3.0/4-PKZ0B3.0/2-PKZ0H-B3-PKZ 0180 (90)Three-phase commoning linksB3.1/5-PKZ0B3.1/4-PKZ0B3.1/3-PKZ0B3.1/2-PKZ02745B3.2/4-PKZ0B3.2/2-PKZ0H-B3-PKZ 0Incoming terminalBK25/3-PKZ0234 (108)6327<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4H-B3-PKZ 0261 (207, 153, 99)2754Overlappingmounting toextend thethree-phasecommoning link73F 567.5 3148BK25/3-PKZ0F 41B3...-PKZ0Three-phase commoning linksThree-phase commoning linksB3.0/5-PKZ0-UB3.1/5-PKZ0-UB3.0/4-PKZ0-UB3.1/4-PKZ0-UB3.0/3-PKZ0-UB3.1/3-PKZ0-UB3.0/2-PKZ0-UB3.1/2-PKZ0-U27.527.5a13.213.6a13.213.6Part no. aB3.0/5-... 215B3.0/4-... 170B3.0/3-... 125B3.0/2-... 80Part no. aB3.0/5-... 215B3.0/4-... 170B3.0/3-... 125B3.0/2-... 80Incoming terminalBK25/3-PKZ0-U154244 33.5For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


8/64DimensionsAccessoriesPKZMO<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4Insulated enclosure for top mountingCI-PKZ0-M801589010070CI-PKZ0-G...M8015897.5125.5CI-K2-PKZ0-...M + SVB-PKZ0-CICI-K2-PKZ0-...M + SVB-PKZ0-CICI-K2-PKZ0-...M + SVB-PKZ0-CICI-PKZ0-...M98303097.5285544SVB-PKZ0-CI81581534.533804.5CI-K2-PKZ0CI-K2-PKZ0G(R)(V)16018116018110047.510047.5104103130CI-K2-PKZ0-G(R)(V) + SVB-PKZ0-CICI-K2-PKZ0-G(R)(V) + SVB-PKZ0-CICI-K2-PKZ0...CI-K2-PKZ0...98303011428M45544SVB-PKZ0-CI1601811713397M4For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616DimensionsAccessories8/65http://catalog.moeller.netDoor coupling handlesPKZ0-XH20o+ l64645548<strong>Moeller</strong> HPL0211-2007/20087.548Mounting depth: 100 to 240 mm fromtop edge of DIN top-hat rail up to frontof panel door/coverClearance of switch shaft/cover hinge:at least 100 mmPKZM0<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM4At least 100 mmup to cover hingeInsulated enclosure for flush mountingE-PKZ0E-PKZ0-GE-PKZ0-... mounting aperture69R412955116 – 11885809612470–72E-PKZ0-G... + SVB-PKZ0-E30983098583028585512955218096124858096124Insulated enclosure for top mountingCI23E-125Mounting platesM3-CI23187.52533142.562.520512525250225262278561141441471771471771627358 × PG 162 × PG 21/29knockout200602159014114.584.514114.584.5279227926 × PG 161 × PG 21/29


<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM48/66DimensionsAccessoriesPKZM01Insulated enclosure for top mountingCI-PKZ01CI-PKZ01-G80CI-PKZ01-SVBCI-PKZ01-SVB-V158CI-PKZ01-PVTCI-PKZ01-PVS116.5 80158<strong>Moeller</strong> HPL0211-2007/2008116.5177.2http://catalog.moeller.net15880116.5129.5Insulated enclosure for flush mountingE-PKZ01E-PKZ01-G69E-PKZ01-PVTE-PKZ01-PVS69129129E-PKZ01-SVBE-PKZ01-SVB-V90.2 93115.290.2 93115.2175.96912990.2 93115.2For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.net<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM4-...130140<strong>Moeller</strong> HPL0211-2007/2008DimensionsAccessories for motor-<strong>protective</strong> <strong>circuit</strong>-breaker4455365125Standard auxiliary contactsNHI...-PKZ...NHI...-PKZ0369 2668PKZM445908/67<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM430 NHI-E... 7.555118127145160NHI-E...<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong> with lockable coverPKZM4-... +AK-PKZ0Trip-indicating auxiliary contactsAGM2...-PKZ...AGM2...-PKZ04AK-PKZ013065140451253645909 266830 7.555Three-phase commoning linksB3.0/4-PKZ4118127145171B3.2/4-PKZ414143620533 26033B3.0/3-PKZ4B3.2/2-PKZ414143636361513311533B3.0/2-PKZ4B3.1/3-PKZ4141436369833 17033B3.1/4-PKZ4B3.1/2-PKZ4141436362323311733


<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZM01, PKZM0, PKZM48/68DimensionsAccessoriesPKZM4Insulated enclosure for top mountingCI-K4-PKZ4-G240<strong>Moeller</strong> HPL0211-2007/2008http://catalog.moeller.net160134181CI-K4-PKZ4-G(R)+SVB-PKZ4-CI9832SVB-PKZ4-CI723Drilling dimensionsCI-K4-PKZ-G(R)o 5.624024019372160 186 2830142For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616Dimensions<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>8/69http://catalog.moeller.net<strong>Moeller</strong> HPL0211-2007/2008<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-breaker and trip blockPKZ2/ZM... + ZMR-...-PKZ2133.5105M419+0ZMR8310510944.5621564568Trip-indicating auxiliary contactsAGM2-11-PKZ218AGM31.545PKZ2PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker1962.571.5Protective switchPKZ24Standard auxiliary contactsNHI...-PKZ281.528.51944.51096105674568105681818NHI 22 NHI 114477118133.5Remote operatorRE-PKZ2(...)RS-PKZ2(...)Shunt releasesUndervoltage releasesU-PKZ2…A-PKZ2...10510536 4518 44109122126109113


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-96168/70Dimensions<strong>Motor</strong>-<strong>protective</strong> <strong>circuit</strong>-<strong>breakers</strong>PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breakerPKZ2High-capacity compact startersPKZ2/ZM-.../SPKZ2/ZM-.../S20411168I>0+71.519M4831902048.510915<strong>Moeller</strong> HPL0211-2007/20086http://catalog.moeller.net2711S-G(Varistor)1256.125S-G(Varistor)18.53862.546.4111.4135.9Standard auxiliary contacts for (high-capacity) compact starterNHI...-PKZ219015318 18 18NHI 22S NHI 2-11S NHI 11SContact modulesHigh-capacity contact moduleCurrent limitersSE1A/11-PKZ2(...)S-PKZ2(...)CL-PKZ24477Bases for separate mountingAuxiliary contact, separate mountingEZ-PKZ2HI11-S/EZ-PKZ2Type -G only3819 M 4533727193862.510103.5854410925365.540.811 10012577


For <strong>Moeller</strong> <strong>Electric</strong> Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.netInsulated enclosures for surface mountingCI19EA-PKZ215099.5<strong>Moeller</strong> HPL0211-2007/2008CI19EB-PKZ2CI19ED-PKZ24DimensionsAccessoriesDrilling dimensionsCI23EA-PKZ2 CI23EB-PKZ2 Drilling dimensions187.546130.520012.5125 M412.5162175PKZ2: E-PKZ, B3…-PKZ, MV-PKZ150M4 187.516215020012.512512.51758/71PKZ2 motor-<strong>protective</strong> <strong>circuit</strong>-breaker99.512.54625022512.5250225130.512.515012.5Insulated enclosure for flush mountingE-PKZ2E54-PKZ2Door coupling handlesPKZ2-X...(R) H-PKZ 2 with serial no. 017.59393+ l1711557M4155o6448123E-PKZ 2111 621301770104Mounting aperturefor 2 – 50 mmpanel thicknessMounting aperturefor 1.5 – 16 mmpanel thickness2064554891At least 100 mmup to cover hingemax. 6 mmThree-phase commoning link Incoming terminal Shroud for unusedterminalsB3.1/3-PKZ2 B3.1/2-PKZ2 BK50/3-PKZ2 H-B3-PKZ222233601403360184.275502584.578.54.5Mechanical interlock with (high-capacity) contact moduleMV-PKZ2Neutral terminal for (high-capacity) contact moduleN-PKZ210 1491021154.5365956.5103.5851.514.61944109128.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!