NESLAB ULT Series Bath Circulators - Equipar.com.mx

NESLAB ULT Series Bath Circulators - Equipar.com.mx NESLAB ULT Series Bath Circulators - Equipar.com.mx

equipar.com.mx
from equipar.com.mx More from this publisher
10.07.2015 Views

NESLAB EX SeriesNESLAB RTE and EX Series Bath CirculatorsSeries SpecificationsNESLAB EX Series familyEX 7 EX 10 EX 17 EX 35Temperature range Ambient +12ºC to 200ºC Ambient +12ºC to 200ºC Ambient +12ºC to 200ºC Ambient +12ºC to 200ºCTemperature stability ±0.01ºC ±0.01ºC ±0.01ºC ±0.01ºCHeater60 Hz 800 watts 800 watts 1600 watts 1600 watts50 Hz 2000 watts 2000 watts 2000 watts 2000 wattsBath volume*gallon 1.9 2.6 4.5 9.3liter 7 10 17 35Pumping performance50Hz/60 Hz (LPM) 15 LPM @ 0’ head 15 LPM @ 0’ head 15 LPM @ 0’ head 15 LPM @ 0’ head50Hz/60 Hz (GPM) 15 GPM @ 0’ head 15 GPM @ 0’ head 15 GPM @ 0’ head 15 GPM @ 0’ headPump force/suction force/suction force/suction force/suctionPump head50 Hz/60 Hz Max head 16’ (4.9M) Max head 16’ (4.9M) Max head 16 ’(4.9M) Max head 16’ (4.9M)Unit dimensionsW x L x D in 14.62 x 9.25 x 17.5 14.62 x 11.38 x 18.25 17.62 x 11.38 x 18.25 20.62 x 11.38 x 25.38W x L x D cm 37.2 x 23.5 x 44.5 37.1 x 28.9 x 46.4 44.8 x 28.9 x 46.4 52.4 x 28.9 x 64.5Bath opening/Bath depthW x D x L in 6.62 x 7.25 x 6 8.62 x 9.38 x 6 8.75 x 9.38 x 9 8.75 x 15.5 x 12W x D x L cm 16.8 x 15.2/23.9 22.4 x 15.2/23.9 22.4 x 15.2/23.9 22.4 x30.5/39.4Power requirements115V, 60 Hz 9 amps 9 amps 16 amps 16 amps100V, 50-60 Hz 9 amps 9 amps 16 amps 16 amps230V, 50 Hz 10 amps 10 amps 10 amps 10 ampsUnit weightlb 26.4 32.0 35.6 52.7kg 12.0 14.5 16.1 23.9*Bath reservoir volume is measured to midpoint of designated fill lines.Stability, pump specifications to 90ºC were determined using water. Other specifications were determined with silicon oil. Reservoir volume measured tomidpoint of designated fill line. Bath opening measured to tank top. Flammable fluids should never be used with these units. Specifications subject tochange without notice.4 Customer Service: 1-800-258-0830 • Web Address: www.thermo.com/tc

Performance CurvesRamp Down 230V/50 Hz UnitsRamp Down 115V/60 Hz UnitsTemperature (°C)Temperature (°C)2001801601401201008060402020018016014012010080604020AABA* B*50 100 150 200 250 300Time (Minutes)Ramp Up 230V/50 Hz UnitsBA* B*CCC*C*DD*DD*With oilA = EX 7B = EX 10C = EX 17D = EX 35With waterA* = EX 7B* = EX 10C* = EX 17D* = EX 35With oilA = EX 7B = EX 10C = EX 17D = EX 35With waterA* = EX 7B* = EX 10C* = EX 17D* = EX 35Temperature (°C)Temperature (°C)200180160140A120B10080604020A* B*20018016014012010080604020C*DC50 100 150 200 250 300Time (Minutes)Ramp Up 115V/60 Hz UnitsA CA*C*B*D*BDD*With oilA = EX 7B = EX 10C = EX 17D = EX 35With waterA* = EX 7B* = EX 10C* = EX 17D* = EX 35With oilA = EX 7B = EX 10C = EX 17D = EX 35With waterA* = EX 7B* = EX 10C* = EX 17D* = EX 35NESLAB RTE and EX Series Bath Circulators25 50 75 100 125Time (Minutes)25 50 75 100 125 150Time (Minutes)Meters Feet4.9 16Pumping CapacityCompatible with AutomaticReservoir Refill AccessoryRS-232 and RS-485communicationsPressure3.7 122.4 81.2 4Drain allowstubing to beadded afterbath is filled0.8 1.6 2.4 3.2 4.0 Gpm3 6 9 12 15 LpmFlowCustomer Service: 1-800-258-0830 • Web Address: www.thermo.com/tc 5

<strong>NESLAB</strong> EX <strong>Series</strong><strong>NESLAB</strong> RTE and EX <strong>Series</strong> <strong>Bath</strong> <strong>Circulators</strong><strong>Series</strong> Specifications<strong>NESLAB</strong> EX <strong>Series</strong> familyEX 7 EX 10 EX 17 EX 35Temperature range Ambient +12ºC to 200ºC Ambient +12ºC to 200ºC Ambient +12ºC to 200ºC Ambient +12ºC to 200ºCTemperature stability ±0.01ºC ±0.01ºC ±0.01ºC ±0.01ºCHeater60 Hz 800 watts 800 watts 1600 watts 1600 watts50 Hz 2000 watts 2000 watts 2000 watts 2000 watts<strong>Bath</strong> volume*gallon 1.9 2.6 4.5 9.3liter 7 10 17 35Pumping performance50Hz/60 Hz (LPM) 15 LPM @ 0’ head 15 LPM @ 0’ head 15 LPM @ 0’ head 15 LPM @ 0’ head50Hz/60 Hz (GPM) 15 GPM @ 0’ head 15 GPM @ 0’ head 15 GPM @ 0’ head 15 GPM @ 0’ headPump force/suction force/suction force/suction force/suctionPump head50 Hz/60 Hz Max head 16’ (4.9M) Max head 16’ (4.9M) Max head 16 ’(4.9M) Max head 16’ (4.9M)Unit dimensionsW x L x D in 14.62 x 9.25 x 17.5 14.62 x 11.38 x 18.25 17.62 x 11.38 x 18.25 20.62 x 11.38 x 25.38W x L x D cm 37.2 x 23.5 x 44.5 37.1 x 28.9 x 46.4 44.8 x 28.9 x 46.4 52.4 x 28.9 x 64.5<strong>Bath</strong> opening/<strong>Bath</strong> depthW x D x L in 6.62 x 7.25 x 6 8.62 x 9.38 x 6 8.75 x 9.38 x 9 8.75 x 15.5 x 12W x D x L cm 16.8 x 15.2/23.9 22.4 x 15.2/23.9 22.4 x 15.2/23.9 22.4 x30.5/39.4Power requirements115V, 60 Hz 9 amps 9 amps 16 amps 16 amps100V, 50-60 Hz 9 amps 9 amps 16 amps 16 amps230V, 50 Hz 10 amps 10 amps 10 amps 10 ampsUnit weightlb 26.4 32.0 35.6 52.7kg 12.0 14.5 16.1 23.9*<strong>Bath</strong> reservoir volume is measured to midpoint of designated fill lines.Stability, pump specifications to 90ºC were determined using water. Other specifications were determined with silicon oil. Reservoir volume measured tomidpoint of designated fill line. <strong>Bath</strong> opening measured to tank top. Flammable fluids should never be used with these units. Specifications subject tochange without notice.4 Customer Service: 1-800-258-0830 • Web Address: www.thermo.<strong>com</strong>/tc

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!