NESLAB ULT Series Bath Circulators - Equipar.com.mx

NESLAB ULT Series Bath Circulators - Equipar.com.mx NESLAB ULT Series Bath Circulators - Equipar.com.mx

equipar.com.mx
from equipar.com.mx More from this publisher
10.07.2015 Views

NESLAB RTE and EX Series Bath CirculatorsBath CirculatorsNESLAB RTE and EX SeriesBath CirculatorsNESLAB RTE Series and EX Series of Bath Circulatorsare Ideal for cooling and heating below, at, or aboveambient temperatures.The RTE and EX Series feature superior coolingand heating power, expansive temperature ranges,powerful force and suction pumps, and sophisticateddigital control technology to ensure reliable andstable control of your liquid temperature procedures.Series SpecificationsNESLAB RTE Series familyRTE 7 RTE 10 RTE 17 RTE 740Temperature range -25ºC to + 150ºC -25ºC to + 150ºC -25ºC to + 150ºC - 40ºC to + 200ºCTemperature stability ±0.01ºC ±0.01ºC ±0.01ºC ±0.01ºCCooling capacity60 Hz 500 watts at 20ºC 500 watts at 20ºC 500 watts at 20ºC 800 watts at 20ºC230V/50 Hz 500 watts at 20ºC 500 watts at 20ºC 500 watts at 20ºC 700 watts at 20ºCHeater60 Hz 800 watts 800 watts 1600 watts 800 watts230V/50 Hz 2000 watts 2000 watts 2000 watts 2000 wattsBath volume*gallon 1.9 2.6 4.5 1.9liter 7 10 17 7Pumping performance50 Hz/60 Hz (LPM) 15 LPM @ 0’ head 15 LPM @ 0’ head 15 LPM @ 0’ head 15 LPM @ 0’ head50 Hz/60 Hz (GPM) 4 GPM @ 0’ head 4 GPM @ 0’ head 4 GPM @ 0’ head 4 GPM @ 0’ headPump force/suction force/suction force/suction force/suctionPump head50 Hz/60 Hz Max head 16’ (4.9M) Max head 16’ (4.9M) Max head 16’ (4.9M) Max head 16’ (4.9M)Unit dimensionsH x W x D in 23.62 x 9.25 x 17.5 23.62 x 11.38 x 18.88 26.62 x 11.38 x 18.88 26.62 x 11.38 x 18.88H x W x D cm 60.0 x 23.5 x 44.5 60.0 x 28.9 x 47.9 67.6 x 28.9 x 47.9 67.6 x 28.9 x 47.9Bath opening/Bath depthW x L x D in 6.62 x 7.25 x 6 8.75 x 9.38 x 6 8.75 x 9.38 x 9 6.62 x 7.25 x 6W x L x D cm 16.8 x 18.3 x 15.2 22.4 x 23.9 x 15.2 22.4 x 23.9 x 22.9 16.8 x 18.3 x 15.2Power requirements115V, 60 Hz 12 amps 12 amps 16 amps 16 amps100V, 50-60 Hz 12 amps 12 amps 16 amps 16 amps230V, 50 Hz 12 amps 12 amps 12 amps 12 ampsUnit weightlb 59.5 67.25 70.25 87kg 27 30.5 31.9 39.5*Bath reservoir volume is measured to midpoint of designated fill lines.Note: A remote sensor option allows you to control the temperature in an external vessel. The sensor comprises a resistance temperature detector (RTD)with a tether. The standard tether is 6 ft. long, and a variety of lengths and diameters are available to suit most any application need.Stability, pump performance and cooling capacity specifications to +5ºC were determined using water. Other specifications were determined using fluidwith specific heat of 0.6, ambient 20ºC. We do not recommend the use of flammable liquids. Specifications subject to change without notice.2 Customer Service: 1-800-258-0830 • Web Address: www.thermo.com/tc

Performance CurvesRTE 740RTE 7, 10, 17 230V/50 Hz UnitsTemperature (°C)Heat Removal (Watts)80706050403020100-10-20-30-4011001000900800700600500400300200100B*A*BA*B*AAB10 20 30 40 50 60 70Time (Minutes)Cooling Capacity-40-30-20-10 0 10 20 30 40 50 60 70 80 90100Temperature °CCBAFluid:WaterA = 115/60B = 230/50Fluid:Specific Heat = 0.6A* = 115/60B* = 230/50A = 115/60 RTE 740 unitsB = 230/50 RTE 740 unitsC = RTE 7, 10, 17Temperature (°C)Temperature (°C)9080706050403020100-10-20-309080706050403020100-10-20-30AA* B*C*A*C*B*BCAB*A*BC*25 50 75 100 125 150Time (Minutes)RTE 7, 10, 17 115V/60 Hz UnitsACABA* B*25 50 75 100 125 150Time (Minutes)BC*CCFluid:WaterA = RTE 7B = RTE 10C = RTE 17Fluid:Specific Heat = 0.6A* = RTE 7B* = RTE 10C* = RTE 17Fluid:WaterA = RTE 7B = RTE 10C = RTE 17Fluid:Specific Heat = 0.6A* = RTE 7B* = RTE 10C* = RTE 17NESLAB RTE and EX Series Bath CirculatorsMeters Feet4.9 16Pumping CapacityCompatible with AutomaticReservoir Refill Accessory3.7 12Pressure2.4 8RS-232 and RS-485communicationsNitrogenPurge Port1.2 4Drain allows tubingto be added afterbath is filled0.8 1.6 2.4 3.2 4.0 Gpm3 6 9 12 15 LpmFlowCustomer Service: 1-800-258-0830 • Web Address: www.thermo.com/tc 3

Performance CurvesRTE 740RTE 7, 10, 17 230V/50 Hz UnitsTemperature (°C)Heat Removal (Watts)80706050403020100-10-20-30-4011001000900800700600500400300200100B*A*BA*B*AAB10 20 30 40 50 60 70Time (Minutes)Cooling Capacity-40-30-20-10 0 10 20 30 40 50 60 70 80 90100Temperature °CCBAFluid:WaterA = 115/60B = 230/50Fluid:Specific Heat = 0.6A* = 115/60B* = 230/50A = 115/60 RTE 740 unitsB = 230/50 RTE 740 unitsC = RTE 7, 10, 17Temperature (°C)Temperature (°C)9080706050403020100-10-20-309080706050403020100-10-20-30AA* B*C*A*C*B*BCAB*A*BC*25 50 75 100 125 150Time (Minutes)RTE 7, 10, 17 115V/60 Hz UnitsACABA* B*25 50 75 100 125 150Time (Minutes)BC*CCFluid:WaterA = RTE 7B = RTE 10C = RTE 17Fluid:Specific Heat = 0.6A* = RTE 7B* = RTE 10C* = RTE 17Fluid:WaterA = RTE 7B = RTE 10C = RTE 17Fluid:Specific Heat = 0.6A* = RTE 7B* = RTE 10C* = RTE 17<strong>NESLAB</strong> RTE and EX <strong>Series</strong> <strong>Bath</strong> <strong>Circulators</strong>Meters Feet4.9 16Pumping CapacityCompatible with AutomaticReservoir Refill Accessory3.7 12Pressure2.4 8RS-232 and RS-485<strong>com</strong>municationsNitrogenPurge Port1.2 4Drain allows tubingto be added afterbath is filled0.8 1.6 2.4 3.2 4.0 Gpm3 6 9 12 15 LpmFlowCustomer Service: 1-800-258-0830 • Web Address: www.thermo.<strong>com</strong>/tc 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!