NESLAB ULT Series Bath Circulators - Equipar.com.mx
NESLAB ULT Series Bath Circulators - Equipar.com.mx NESLAB ULT Series Bath Circulators - Equipar.com.mx
Optimize performance from day one• Quick, efficient installation.• Optimize performance.• Accelerate payback.• Validate your warranty via inspection by a certifiedThermo Electron Corporation field representativeControl NESLAB CB TechnologiesSeriesPerformance INITIATIONMaintaining operational excellence requires achieving it first Thermo Electron CorporationPerformance INITIATION service ensures ROI realization from day one.Available start-up services• Solution integration and implementationplanning•Site supervision of construction inpreparation for system installation•Installation qualification• Operation qualification• System calibrated to the application• Operator training• Interface with licensing agencies•Installation inspection•Warranty validationBenefits• Optimum performance from day one• Faster payback on your investment• Compliance with FDA requirements forsystem qualification as discussed in 21CFR Part 11• Reduction in total engineering costs ascompared to managing multiple vendorrelationships• Reduced overall time from project releaseto system startupStartup Service exampleChecklist for Temperature Control SystemStep Activity1 Check power, volts, HZ, phase, and amps from power source2 Check plumbing connections, line size, and line length3 Check location of unit, air flow and serviceability4 Fill tank, check for leaks, and open all valves5 Start unit, check pump, compressor, fans, and controller6 Purge lines of air, top off tank, and check for leaks7 Unit calibration – adjust controller set point, high and low temperature limitswitches, and flow switch8 Add heat load, ensure unit maintains temperature set point and runs to allThermo specifications9 Check refrigeration pressures10 Review completed procedures with the customer and answer any questions11 Validate unit warranty12 Provide certificate as written proof of compliance to industry standards, ifrequired13 Provide cursory operator training (in-depth operator and maintenance training isavailable as an optional service)30 Customer Service: 1-800-258-0830 • Web Address: www.thermo.com/tc
- Page 1: NESLAB TemperatureBioscience Contro
- Page 5 and 6: Refrigerated and Heating Circulatin
- Page 7 and 8: Performance CurvesRTE 740RTE 7, 10,
- Page 9 and 10: Performance CurvesRamp Down 230V/50
- Page 11 and 12: NESLAB RPC — Programmable Control
- Page 13 and 14: Low-Temp Bath Circulator SystemsNES
- Page 15 and 16: NESLAB ULT Series Bath CirculatorsS
- Page 17 and 18: Cold BathsNESLAB RTE CB Series Cold
- Page 19 and 20: Performance CurvesTime to Temperatu
- Page 21 and 22: Recirculating Chiller SystemsNESLAB
- Page 23 and 24: NESLAB Merlin Series Recirculating
- Page 25 and 26: Immersion Cooling SystemsNESLAB CC
- Page 27 and 28: NESLAB CB Series CryotrolCryotrol O
- Page 29 and 30: Service AgreementsPerformance Servi
- Page 31 and 32: Performance PLUSEnhanced service re
- Page 33: Protect your biggest investment - y
Optimize performance from day one• Quick, efficient installation.• Optimize performance.• Accelerate payback.• Validate your warranty via inspection by a certifiedThermo Electron Corporation field representativeControl <strong>NESLAB</strong> CB Technologies<strong>Series</strong>Performance INITIATIONMaintaining operational excellence requires achieving it first Thermo Electron CorporationPerformance INITIATION service ensures ROI realization from day one.Available start-up services• Solution integration and implementationplanning•Site supervision of construction inpreparation for system installation•Installation qualification• Operation qualification• System calibrated to the application• Operator training• Interface with licensing agencies•Installation inspection•Warranty validationBenefits• Optimum performance from day one• Faster payback on your investment• Compliance with FDA requirements forsystem qualification as discussed in 21CFR Part 11• Reduction in total engineering costs as<strong>com</strong>pared to managing multiple vendorrelationships• Reduced overall time from project releaseto system startupStartup Service exampleChecklist for Temperature Control SystemStep Activity1 Check power, volts, HZ, phase, and amps from power source2 Check plumbing connections, line size, and line length3 Check location of unit, air flow and serviceability4 Fill tank, check for leaks, and open all valves5 Start unit, check pump, <strong>com</strong>pressor, fans, and controller6 Purge lines of air, top off tank, and check for leaks7 Unit calibration – adjust controller set point, high and low temperature limitswitches, and flow switch8 Add heat load, ensure unit maintains temperature set point and runs to allThermo specifications9 Check refrigeration pressures10 Review <strong>com</strong>pleted procedures with the customer and answer any questions11 Validate unit warranty12 Provide certificate as written proof of <strong>com</strong>pliance to industry standards, ifrequired13 Provide cursory operator training (in-depth operator and maintenance training isavailable as an optional service)30 Customer Service: 1-800-258-0830 • Web Address: www.thermo.<strong>com</strong>/tc