4–ConfigurationConfiguring Fibre Channel Array Hosts and LUN AssignmentsWhen assigning LUNs to your VPG host entities, you must not assign the sameLUN to two VPG host entities. Figure 4-12 shows a valid LUN presentation. EachLUN is presented to only one VPG. Any of these LUNs can be presented to anynumber of other Fibre Channel hosts on the array, but can be presented to oneand only one VPG of the <strong>iSR6200</strong>.<strong>Storage</strong> Array<strong>iSR6200</strong>FC1Blade 1FC221:00:00:c0:dd:13:16:f821:01:00:c0:dd:13:16:f821:02:00:c0:dd:13:16:f821:00:00:c0:dd:13:16:f921:01:00:c0:dd:13:16:f921:02:00:c0:dd:13:16:f9Host EntitiesHost Entity 021:00:00:c0:dd:13:16:f821:00:00:c0:dd:13:16:f9Host Entity 121:01:00:c0:dd:13:16:f821:01:00:c0:dd:13:16:f9Host Entity 221:02:00:c0:dd:13:16:f821:02:00:c0:dd:13:16:f9LUN 1LUN 2LUN 3LUN 4Figure 4-12. Correctly Assigning LUNs to Your VPG Host EntitiesISR651101-00 G 4-15