4–ConfigurationConfiguring Fibre Channel Array Hosts and LUN AssignmentsConfiguring Fibre Channel Array Hosts and LUNAssignmentsWhen configuring Fibre Channel array hosts, you must treat each <strong>iSR6200</strong> virtualport group (VPG) as its own unique Fibre Channel host within the virtualizedstorage array. This means if you have only one VPG enabled, the <strong>iSR6200</strong> willhave only one host entity. If you enable two more VPGs, the <strong>iSR6200</strong> presentsthree separate host entities to your storage array.Each host entity must contain WWPNs from the same VPG. Figure 4-8 shows acorrect configuration.Figure 4-8. Correctly Configured <strong>Storage</strong> Array Using Virtual Port GroupsDo not simply group all Fibre Channel ports from the <strong>iSR6200</strong> router into a singlehost entity. Doing so defeats the purpose of virtual port groups, limiting you to 256LUNs. It will also cause problems when you later try to restore access toadditional LUNS.4-12 ISR651101-00 G