TERRA CL 08 - 33 Air - Water - Heatpump
TERRA CL 08 - 33 Air - Water - Heatpump TERRA CL 08 - 33 Air - Water - Heatpump
TERRA CL 08 - 33 Air - Water - Heatpump Heatpumps Operation Manual Version 24.06.08 ba_TERRA CL eng
- Page 2 and 3: Table of contents Operation 3 Heati
- Page 4 and 5: Heating Controller IDM THETA Genera
- Page 6 and 7: Temperature Settings Operational mo
- Page 8 and 9: Setting the heating characteristics
- Page 10 and 11: Programming level - Level summary S
- Page 12 and 13: Copy operating times Seite 12
- Page 14 and 15: Table for individual operating time
- Page 16 and 17: Seite 16
- Page 18 and 19: Unmixed circuit, mixed circuit 1, m
- Page 20 and 21: Manual Mode Seite 20
- Page 22 and 23: Trouble shooting Seite 22 Operation
<strong>TERRA</strong> <strong>CL</strong> <strong>08</strong> - <strong>33</strong><br />
<strong>Air</strong> - <strong>Water</strong> - <strong>Heatpump</strong><br />
<strong>Heatpump</strong>s<br />
Operation<br />
Manual<br />
Version 24.06.<strong>08</strong><br />
ba_<strong>TERRA</strong> <strong>CL</strong> eng
Table of contents<br />
Operation 3<br />
Heating Controller IDM THETA 4<br />
General Operation 4<br />
Standard Operating Modes 5<br />
Temperature Settings 6<br />
Operational mode selection for heating and hot water 6<br />
Functions of operational modes 7<br />
Quick operational mode selection 7<br />
Setting the heating characteristics (heating curve) 8<br />
Plant Information 9<br />
Programming level - Level summary 10<br />
Programming of operating times 11<br />
System 15<br />
Domestic Hot <strong>Water</strong> 17<br />
Unmixed circuit, mixed circuit 1, mixed circuit 2 18<br />
Time - Date 19<br />
Error Messages 19<br />
Manual Mode 20<br />
Defrost Controller 21<br />
Bedienung 21<br />
Bedienebenen 21<br />
Benutzerebene 22<br />
Trouble shooting 23<br />
Seite 2
Operation<br />
The<strong>TERRA</strong>heat pump is switched on and off fully automated<br />
by the Multi talent control.<br />
For a proper operation of the controls the manual has<br />
to be looked up.<br />
An annual service and maintenance of the installation<br />
by a customer service is recommended in concern<br />
of warranty claims.<br />
Main Switch<br />
Enable Heating rod<br />
Main Switch:<br />
Switch the control circuit and the main connection for the<br />
heating rod and the compressor.<br />
Enable:<br />
Enables the heatpump<br />
Heating rod:<br />
It can be switched between different operating methods:<br />
0: the heating rod is disabled<br />
I: the heating rod runs if the two - valent condition<br />
point is below the target and there is a upon load<br />
dependent request.<br />
II: the heating rod runs if there is only a upon load<br />
dependent request.<br />
In Mode I and II the heating rod will run in case of an<br />
error.<br />
Defrost Controller Heating Controller<br />
Defrost Controller:<br />
This controller optimizes the defrost process of the heatpump<br />
and monitoring errors.<br />
Heating controller:<br />
This is the main controller for heating circuits, domestic<br />
hot water, circulation pumps and time programms.<br />
Seite 3
Heating Controller IDM THETA<br />
General Operation<br />
Seite 4
Standard Operating Modes<br />
Seite 5
Temperature Settings<br />
Operational mode selection for heating and hot water<br />
Seite 6
Functions of operational modes<br />
Quick operational mode selection<br />
Seite 7
Setting the heating characteristics (heating curve)<br />
Seite 8
Plant Information<br />
Seite 9
Programming level - Level summary<br />
Seite 10
Programming of operating times<br />
Seite 11
Copy operating times<br />
Seite 12
Return loading of standard programs - deleting of individual operating-times programs<br />
Seite 13
Table for individual operating times and programs<br />
Seite 14
System<br />
Seite 15
Seite 16
Domestic Hot <strong>Water</strong><br />
Seite 17
Unmixed circuit, mixed circuit 1, mixed circuit 2<br />
Seite 18
Time - Date<br />
Error Messages<br />
Seite 19
Manual Mode<br />
Seite 20
Defrost Controller<br />
The defrost controller RAM100A is put in for the demanddependent<br />
defrosting of iced over evaporator of air/waterheat<br />
pumps and coolinginstallations. This leads to a<br />
better performancedigit and considerable energy-savings.<br />
Appliance<br />
Reset of any error:<br />
Press No / - to reset the alarm or error<br />
Seite 21
Trouble shooting<br />
Seite 22<br />
Operation lamp<br />
Fault lamp<br />
The heat pump is equipped with a variety of safety applications<br />
to protect the machine for possible faults.<br />
If the heat pump is contrary to expectation not running,<br />
so the following things have to be checked:<br />
Is the green operation lamp shining?<br />
Is the humming fault light shining ?<br />
If not: Check the main fuse of the heatpump connection.<br />
In case of a series of High pressure, low pressure or Thermorelais faults, please contact your<br />
customer service!<br />
Customer service phone number:___________________________________
IDM - Servicetechnik<br />
IDM - Akademie<br />
Ihr IDM- Vor- Ort- Partner:<br />
© IDM - Energiesysteme GmbH / Änderungen vorbehalten<br />
InbETRIbnAHME - WARTUnG - SERvICE<br />
Unsere Service-Techniker helfen gerne Vorort. Ihren<br />
regionalen Ansprechpartner mit Kontaktdaten finden<br />
Sie auf unserer Website www.idm-energie.com<br />
PRAxISWISSEn FüR vERkAUF UnD TECHnIk<br />
Das umfangreiche Seminarangebot für Fachleute bei der<br />
IDM-ENERGIEFAMILIE steht für Sie jederzeit auf unserer<br />
Website www.idm-energie.com zur Verfügung.<br />
Wir freuen uns über Ihre Anmeldung.<br />
DIE EnERGIEFAMILIE<br />
DIE IDM ZEnTRALE In MATREI In OSTTIROL<br />
IDM- ENERGIESYSTEME GMBH<br />
Seblas 16 - 18<br />
9971 Matrei in Osttirol<br />
Telefon + 43 (0)4875 6172 - 0<br />
Telefax + 43 (0)4875 6172 - 85<br />
E-mail team@idm-energie.at<br />
Seminar- News www.idm-akademie.com<br />
Wasserhygiene- News www.krankgeduscht.com