10.07.2015 Views

Specification Thermopile Sensor HMS-J21-F4.26 R 0.1

Specification Thermopile Sensor HMS-J21-F4.26 R 0.1

Specification Thermopile Sensor HMS-J21-F4.26 R 0.1

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

HEIMANN <strong>Sensor</strong> GmbHProduct <strong>Specification</strong>:<strong>Thermopile</strong> <strong>Sensor</strong><strong>HMS</strong>-<strong>J21</strong>-<strong>F4.26</strong>Author(s): W. Leneke, M. Simon Rev.: R <strong>0.1</strong> / 09.07.2004 Page 1 of 5<strong>Specification</strong> <strong>Thermopile</strong> <strong>Sensor</strong><strong>HMS</strong>-<strong>J21</strong>-<strong>F4.26</strong>R <strong>0.1</strong>Author(s):W. Leneke, M. SimonRevision HistoryVersion Date RemarksR <strong>0.1</strong> 09.07.2004 1. Draft of HEIMANN <strong>Sensor</strong> GmbH<strong>Specification</strong>_<strong>Thermopile</strong><strong>Sensor</strong>_<strong>HMS</strong> <strong>J21</strong>-<strong>F4.26</strong>.doc© HEIMANN <strong>Sensor</strong> GmbH


HEIMANN <strong>Sensor</strong> GmbHProduct <strong>Specification</strong>:<strong>Thermopile</strong> <strong>Sensor</strong><strong>HMS</strong>-<strong>J21</strong>-<strong>F4.26</strong>Author(s): W. Leneke, M. Simon Rev.: R <strong>0.1</strong> / 09.07.2004 Page 3 of 54. General and Electrical Parameter ThermistorTypeThermistor 100kΩParameter Symbol Limits Units ConditionsMin Typ Maxresistance R Th 95 100 105 kΩ 25°CBETA-value β 3900 3940 3980 K 25°C/50°CT / °C R Th min / Ohm R Th nom / Ohm R Th max / Ohm-30 1557900 1655000 1753100-25 1163320 1234000 1306680-20 875826 928700 981974-15 665010 704500 744190-10 508730 538500 568370-5 392108 414600 4372920 304466 321700 3389345 238072 251400 26472810 187444 197800 20805615 148568 156600 16463220 118404 124800 13109625 95000 100000 10500030 76537 80630 8471335 62032 65380 6873840 50543 53310 5607745 41386 43680 4598450 34070 35980 3789055 28174 29770 3136660 23405 24750 2609565 19536 20670 2180470 16383 17340 1829775 13788 14600 1542280 11653 12350 1304785 9890 10480 1108090 8421 8930 944495 7197 7635 8076100 6172 6551 6935<strong>Specification</strong>_<strong>Thermopile</strong><strong>Sensor</strong>_<strong>HMS</strong> <strong>J21</strong>-<strong>F4.26</strong>.doc© HEIMANN <strong>Sensor</strong> GmbH


HEIMANN <strong>Sensor</strong> GmbHProduct <strong>Specification</strong>:<strong>Thermopile</strong> <strong>Sensor</strong><strong>HMS</strong>-<strong>J21</strong>-<strong>F4.26</strong>Author(s): W. Leneke, M. Simon Rev.: R <strong>0.1</strong> / 09.07.2004 Page 4 of 55. Filter CharacteristicsFilter <strong>F4.26</strong>Parameter Limits Units ConditionsMin Typ. MaxCenter wavelength(CWL)4.05 4.26 4.51 µmHalf power bandwidth(HPB)160 180 200 nmHPB/CWL 4.2 %Peak transmittance 73 %Blocking T average < <strong>0.1</strong>% % from UV to band passT peak < 1% % from UV to band passT peak < 1% % from band pass to 12µmFilter <strong>F4.26</strong>Transmission / %10090807060504030201003,6 3,8 4 4,2 4,4 4,6 4,8Wavelength / µmFilter <strong>F4.26</strong><strong>Specification</strong>_<strong>Thermopile</strong><strong>Sensor</strong>_<strong>HMS</strong> <strong>J21</strong>-<strong>F4.26</strong>.doc© HEIMANN <strong>Sensor</strong> GmbH


HEIMANN <strong>Sensor</strong> GmbHProduct <strong>Specification</strong>:<strong>Thermopile</strong> <strong>Sensor</strong><strong>HMS</strong>-<strong>J21</strong>-<strong>F4.26</strong>Author(s): W. Leneke, M. Simon Rev.: R <strong>0.1</strong> / 09.07.2004 Page 5 of 56. Drawing and Pin Assignment6. LiabilityChanges or modifications at the product which haven't influence to the performanceand/or quality of the device haven't to be announced to the customers in advance.Customers are requested to consult with Heimann <strong>Sensor</strong> representatives before theuse of Heimann <strong>Sensor</strong> products in special applications where failure or abnormaloperation may directly affect human lives or cause physical injury or propertydamage. The company or their representatives will not be responsible for damagearising from such use without prior approval.<strong>Specification</strong>_<strong>Thermopile</strong><strong>Sensor</strong>_<strong>HMS</strong> <strong>J21</strong>-<strong>F4.26</strong>.doc© HEIMANN <strong>Sensor</strong> GmbH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!