R<strong>IceStop</strong> GMK-RC <strong>Roof</strong> <strong>Clip</strong> <strong>and</strong>GM-RAKE <strong>Hanger</strong> <strong>Braket</strong>Installation InstructionsThe GMK-RC <strong>Roof</strong> <strong>Clip</strong> <strong>and</strong> GM-RAKE <strong>Hanger</strong> Bracket Kits are for use withRaychem <strong>IceStop</strong> heating cables. Carefully follow these instructions. Donot use other hardware or techniques which may damage the heating cable<strong>and</strong> cause electrical hazard, fire damage or poor performance.GMK-RCGMK-RCThe GMK-RC roof clips are used to secure <strong>IceStop</strong> heating cables to roofs<strong>and</strong> gutters. For applications where you will be using this clip to install theheating cable with a nail or screw, go to page 2. For applications whereyou will be using this clip to install the heating cable with adhesives, go topage 3.GM-RAKEThe GM-RAKE hanger bracket is used to provide mechanical protection tothe <strong>IceStop</strong> heating cable as it goes over sharp edges <strong>and</strong> to hold theheating cable in place at the top of downspouts. Refer to page 4 forinstruction on how to install the GM-RAKE hanger bracket.GM-RAKEApprovalsThe GMK-RC <strong>and</strong> GM-RAKE kits are approved for use with UL Listed,FM Approved, <strong>and</strong> CSA Certified <strong>IceStop</strong> heating cable systems.Shingle <strong>Roof</strong>GMK-RCGM-RAKEMetal St<strong>and</strong>ing Seam <strong>Roof</strong>GMK-RCGM-RAKE


4GMK-RC <strong>and</strong> GM-RAKE Installation InstructionsInstalling GM-RAKE in Gutter12• Bend the GM-RAKE toapproximately 90°.• Insert cable ties throughholes on GM-RAKE.• Position the GM-RAKE<strong>and</strong> tighten the cable ties.• Trim off excess cable tie.3a Installing GM-RAKE in Downspout3b Installing GM-RAKE for Mechanical Protection• GM-RAKE should becentered on the edgeof the downspout toprevent mechanicaldamage <strong>and</strong> to supportthe heatingcable.GM-RAKEGM-RAKE• Use the GM-RAKE to protectthe heating cable from sharpedges.Installing GM-RAKE as a Spacer• GM-RAKE can alsobe used in one oftwo orientations ina wide gutter as aspacer.Wideorientation<strong>IceStop</strong> is a trademark of Raychem Corporation.Narroworientation©1999 Raychem Corporation PN603717 H56690 3/99Telecommunications, Energy <strong>and</strong>Industrial DivisionRaychem Corporation300 Constitution DriveMenlo Park, California 94025-1164Tel (800) 545-6258Fax (800) 611-2323cheminfo@raychem.comwww.raychem.comRaychem Canada LimitedToronto, OntarioCanadaTel (800) 545-6258Fax (650) 811-0323

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!