10.07.2015 Views

Operating Manual - Webshop, Gas Analysis Technology

Operating Manual - Webshop, Gas Analysis Technology

Operating Manual - Webshop, Gas Analysis Technology

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1512 INSTALLATION INSTRUCTIONSThe EC-30(/FD) cooler is equally suitable for wall mounting or for installation in a 19" rack.NOTE!Please state the desired type of mounting when ordering, so that the LEDfunction display can be positioned to match at the factory!NOTE!The operating position for this cooler is exclusively vertical. This is the onlyway to ensure proper separation and removal of condensate in the heatexchangers. During transport and when in storage, the cooler has always tostand vertical with the transport feet positioned underneath so that the oil inthe closed compressor circuit cannot run out of this compressor case.The cooler should be kept away from sources of heat and well ventilatedwhen installed, to avoid interfering heat accumulation.The minimum installation dimensions (fig. 2) must be followed without fail. Ifthe unit is installed outdoors, the cooler must be installed in a housing thatis frost-free in winter and adequately ventilated in summer. Avoid locatingthe unit in direct sunlight.Unheated gas sample lines have to be run with slope up to the cooler. In thatcase pre-separation of the condensate is not required.Connect the heated sample line with sufficient thermal decoupling to thecooler!13 SUPPLY CONNECTIONS13.1 HOSE CONNECTIONSThe hoses for the heat exchangers are connected as shown in figure 4.NOTE!Do not mix up the hose connections; the inlet and outlet connections of theheat exchangers are marked with arrows;Exit hose of the low-temperature stage (fig. 4) is marked red.Ensure that the connections are sealed adequately;To ensure free removal of the condensate, ensure that the listed diametersfor the condensate removal lines are not reduced!Ensure that the connections are sealed adequately by noting the following:Duran glass heat exchangers with GL connectionsBefore assembly, check the GL coupling rings to see if the PTFE/silicon locking rings have beendamaged;The locking rings should be installed with the PTFE side facing the medium.PVDF heat exchangers with PVDF tube connectorsCarefully remove the nuts from the coupling body so that the ferrule that is loose inside the nutwill not be lost.Push the union nut first, and then the ferrule with the thick bulb facing the nut, onto the 4/6 mmhose.Push the hose onto the support nipple in the coupling body and tighten the union nut hand-tight.<strong>Gas</strong> sampling and gas conditioning technology3-4.20-ME

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!