Ordering InformationGenerate the required ordering code as follows: e.g. 2V165 BBBBA2V1651 2 3 4 51 AUXILIARY SUPPLY RANGEA 20-70V DC B 40-300V DC / 40-275V AC2 DIGITAL INPUT OPERATING VOLTAGE – GROUP 1Opto-isolated inputABC24-80V AC/DC75-150V AC/DC150-300V AC/DC3 DIGITAL INPUT OPERATING VOLTAGE – GROUP 2Opto-isolated inputABC24-80V AC/DC75-150V AC/DC150-300V AC/DC4 DIGITAL INPUT OPERATING VOLTAGE – GROUP 3Opto-isolated inputABC24-80V AC/DC75-150V AC/DC150-300V AC/DC5 TPI ANALOGUE OUTPUTSABNot requiredRequired 4 to 20mATAP POSITION LOGIC TABLE FIRMWAREA Not required Matched tap changersB Non matched tap changers Complete the table on page 22V165 wiring diagram - <strong>Relay</strong> shown in de-energised condition 1COMMUNICATIONS(RS 232 SCADA option)D9RS232 PC Programming port<strong>Transformer</strong> 1 IN GROUPStatus input group 1<strong>Transformer</strong> 2 IN GROUPVx35797252723303432Powersupply /CPU failalarmTap raise<strong>Transformer</strong> 1Tap lowerNetworkport242628SENDRECEIVEGROUND<strong>Transformer</strong> 3 IN GROUPStatus input group 2111315364038Tap raise<strong>Transformer</strong> 2Tap lowerCOMMUNICATIONS(RS 485 SCADA option)D9RS232 PC Programming port<strong>Transformer</strong> 4 IN GROUPTap raise input commandStatus input group 3Tap lower input commandGo to specified tap1316221822202242464448525019Tap raise<strong>Transformer</strong> 3Tap lowerTap raise<strong>Transformer</strong> 4Tap lowerNetworkportBIAS linksJ19 J18242628SHIELDRS485 Shielded twistedpair cable (Up to 1Km)120 OhmTo other uMATRIX relays (Up to 32 units)Fit external terminating resistor to end of BUS relay onlyFit internal BIAS jumper links for single relay connection only<strong>Transformer</strong> 1 tap position indicator input<strong>Transformer</strong> 2 tap position indicator input<strong>Transformer</strong> 3 tap position indicator input<strong>Transformer</strong> 4 tap position indicator input35373941434547492117108141253552Out of stepalarmTap ChangefeedbackAll OFF LINETap positionoutputVisit www.rmspl.com.au for the latest product information.Due to RMS continuous product improvement policy this information is subject to change without notice. 2V165/Issue E - 17/11/08 - 44

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!