10.07.2015 Views

friction clutches - Arten Freios e Embreagens Industriais

friction clutches - Arten Freios e Embreagens Industriais

friction clutches - Arten Freios e Embreagens Industriais

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Table of ContentsWeb ProductsGC 300 WEB GUIDE CONTROLLERSWEB GUIDING CONTROLS ◗Easy Calibration, Set-up andOperationMaximum Output:24VDC at 6 amps max.Smart over-current protection andindication. Protects motors while allowingfull force operation when needed.0.50''[12,70]0.62''[15,75]Dimensions8.25''[209,55]6.00''[152,40]8.94''[227,08]7.00''[177,80]INCH[MM]0.57''[14,48]4.25''[107,95]3.69''[93,73]0.07''[1,78]Thermal overload protection of driverstages. Motor miswiring warning.Determines and displays motor wiring errors.SETUPRight and left travel limit protection andindication. (Both visual and relay closure).10.25''[260,35]SENSOR10.75''[273,05]Sensor type selection.Dip-switch selection of ultrasonic, LED,or Line Follower type sensor.Automatic sensor calibration.Sets optimal offset, gain and deadband.11.50''[292,10]ENTERGC 300Manual sensor calibration to override theautomatic settings when needed.Programmable sensor offset (with faultindication).Remote sensor offset.A remote pot. can be used to electronicallyoffset the center of the guide sensor.0.62''[15,75]0.31'' [7,87] Dia. 5X0.875'' [22,225] Dia. Hole 6X0.38''[96,52]Instrumentation output available.Center guiding available.(Use daughter board accessory for secondsensor). Automatically enabled when daughterboard is present.Auto-center function included standard.Operates with either reed switch orproximity sensor input.Front panel membrane switches.Allows all calibration to be accomplishedfrom the front panel.Front panel LED bar graph for rapidinterpretation of status.Used to display web position within thesensor window; and also display faults andparameters during calibration.Factory settings stored in memory.Return the unit to “factory parameter status”quickly and easily.Sealed for use in dusty environments.CE Marked1.94''[49,28]0.69''[17,53]0.69''[17,53]2.06''[52,32] 3.44''[87,38]SpecificationsAccuracyPowerAmbient Temp.RangeInputsStandardStandardOptionalAuto-center SwitchEnd-of-TravelRemote Offset PotOutputsMotorEnd-of-TravelWeb Position0.75''[19,05]KNOCK-OUT SEAL (3)± 0.004" [0,1mm] with Appropriate sensors110 VAC or 220 VAC, 160 VA at 50/60 Hz32° F. to 120° F. (0° C. to 50° C.)Line Follower LH100 (Requires second sensor board)One Ultrasonic UH21 or One Infrared LED PH16Second UH21 or PH16 (requires daughter board)Either Limit Switch or Proximity Switch (Auto-Detect)Limit Switches2kΩ Pot. (customer supplied))6 amp Max, 24 VDC, Over Current protectedSPDT Relays, Rated 0.3 amp max. @ 24 VDCIndication: 0-10 V321

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!