10.07.2015 Views

friction clutches - Arten Freios e Embreagens Industriais

friction clutches - Arten Freios e Embreagens Industriais

friction clutches - Arten Freios e Embreagens Industriais

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Table of ContentsWeb ProductsSIDEWALL MOUNT TENSION SENSORMeasures web tension in unwind, intermediate and rewind applicationsTENSION CONTROLS ◗DimensionsA C D G H K L M N O P1.25 1.95 Not used 2.61 1.77 2.26 3.18 .4025 3.25 0.59 4.00WITH FLANGE [31,8] [49,5] Not used [66,2] [45] [57,2] [80,7] [10,3] [82,5] [14,9] 101,61.25 1.95 1/2-13 x 0.55DP 2.45 1.77 2.26 3.02 Not usedWITHOUT FLANGE [31,8] [49,5] [12,7]-13 x [14]DP [62,2] [45] [57,2] [76,7] Not usedNotes: • All dimensions shown in inches. [mm] • Allow 2-1/2 inches [63.5] clearance for connector. • Maximum roller shaft length = distance between sidewalls - (2x G)Selection Chart Cables InstallationSensorStandard CableForce (lbs) (N) Product Number Provided with each Product Number25 111 803351 sensor 16 foot [5m] 3051850 222 803352 Optional Cables75 334 803353 Length (ft.) (M) Product Number100 445 80335425 7,6 15596150 667 80335530 9,1 15869200 890 80335650 15,2 15870Selection of Force RatingThe proper sensor force ratingfor any application is calculatedusing known values for maximumweb tension, wrap angle andidler roll weight. To calculatethe force rating, first select theappropriate wrap configuration,1, 2 or 3. Then calculate theforce using the formula for thatwrap configuration.Selection of Force RatingWRAP 1Tension Force,F T above horizontalThese formulas allow for atension transient of 2 times theaverage tension. Thus, in somecases, it may be appropriate touse a sensor pair with a forcerating slightly less than thecalculated net force.In some applications, a transducerroll can be so heavy thatits weight takes up the operatingrange weight of the sensors. IfWRAP 2Tension Force,F T below horizontalthis happens, it may not bepossible to zero the tensionwhen the transducer roll isunloaded. This is caused byexceeding the adjustmentrange of the tension controlleror meter.To determine if your idler roll istoo heavy, compare the forcerating with the effective weightof the roll using this formula: IfW COS (A) is more than 95%WRAP 3Tension Force,F T is horizontalof the force rating selected, thetension meter or controller cannotbe adjusted to zero. If this is thecase, one or more of thesechanges must be made toreduce W COS (A) to less than95% of the force rating:• Reduce the sensor roll weight• Increase angle (A)• Use the next higher forcerating (this is not desirable assensor signal output is reduced)303

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!