10.07.2015 Views

TS 93 DORMA - The Building Product Directory

TS 93 DORMA - The Building Product Directory

TS 93 DORMA - The Building Product Directory

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DORMA</strong> <strong>TS</strong> <strong>93</strong> EMRY Size EN 2-5Cam action door closerconforming to EN 1154,carries the CE mark, Conturdesign, with rapidlydecreasing opening torque/force. Pull-side fixing. Closingspeed, latching speed,hydraulically controlled backcheckand delayed actionconveniently adjustable atvalves accessible from thefront. Mounting bracket withuniversal fixing hole system.Non-handed.Slide channel assembly withintegral smoke detectorfeaturing standby and maintenanceindicators and electro-mechanicalhold-open,24 V DC, conforming toEN 1155. Hold-open point(80° - 120°) and pull-offforce infinitely variable. Afloating (volt-free) alarmcontact and connections forfurther detectors and externalmanual release devicesare provided. One-piececover. Overall height 30 mm.Approved by the GermanInstitute for <strong>Building</strong>Technology, Berlin, for useas a hold-open unit.Acceptance inspection ofthe system is mandatory.ModelY <strong>TS</strong> <strong>93</strong> EMR with integratedpower pack.Power supply 230 V AC,operating voltage 24 V DCY <strong>TS</strong> <strong>93</strong> EMR DCWSmoke detector withoutpower pack for connectionto DCW bus.Y Optional integral alarmmodule adding an audiblesignal to the visual indicator.ColourY silverwhite, sim. to RAL Y 9010Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)Make<strong>DORMA</strong> <strong>TS</strong> <strong>93</strong> EMR, EN 2-5<strong>DORMA</strong> <strong>TS</strong> <strong>93</strong> EMR DCW,EN 2-5<strong>DORMA</strong> <strong>TS</strong> <strong>93</strong>G EMRY Size EN 2-5Cam action door closer conformingto EN 1154, carriesthe CE mark, Contur design,with rapidly decreasingopening torque/force. Pushsidefixing. Closing speed,latching speed, hydraulicallycontrolled backcheck anddelayed action convenientlyadjustable at valves accessiblefrom the front. Mountingbracket with universal fixinghole system. Non-handed.Slide channel assembly withintegral smoke detector featuringstandby and maintenanceindicators, powerpack and electro-mechanicalhold-open, 24 V DC, conformingto EN 1155.Hold-open point (80° - 120°)and pull-off force infinitelyvariable. A floating (volt-free)alarm contact and connectionsfor further detectorsand external manual releasedevices are provided.One-piece cover. Overallheight 30 mm.Approved by the GermanInstitute for <strong>Building</strong>Technology, Berlin, for useas a hold-open unit.Acceptance inspection ofthe system is mandatory.ModelY <strong>TS</strong> <strong>93</strong> EMR withintegrated power pack.Power supply 230 V AC,operating voltage 24 V DCY <strong>TS</strong> <strong>93</strong> EMR DCWSmoke detector withoutpower pack for connectionto DCW bus.Y Optional integral alarmmodule adding an audiblesignal to the visual indicator.ColourY silverwhite, sim. to RAL Y 9010Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)Make<strong>DORMA</strong> <strong>TS</strong> <strong>93</strong>G EMR, EN 2-5<strong>DORMA</strong> <strong>TS</strong> <strong>93</strong>G EMR DCW,EN 2-5<strong>DORMA</strong> RMZSmoke detector, Conturdesign, with standby andmaintenance indicators,integral power pack andoptical smoke sensor fortransom/lintel fixing.For activation of <strong>DORMA</strong>hold-open devices.A floating (volt-free) alarmcontact and connections forfurther detectors and externalmanual release devicesare provided.Can be switched to manualreset. One-piece cover.Overall height 30 mm.Approved by the GermanInstitute for <strong>Building</strong>Technology, Berlin, for usein a hold-open system.Acceptance inspection ofthe system is mandatory.ModelY RMZ with integratedpower pack.Power supply 230 V AC,operating voltage 24 V DCY RMZ DCWSmoke detector withoutpower pack for connectionto DCW bus.Y Optional integral alarmmodule adding an audiblesignal to the visual indicator.ColourY silverwhite, sim. to RAL Y 9010Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)Make<strong>DORMA</strong> RMZ<strong>DORMA</strong> RMZ DCW<strong>DORMA</strong> RMUniversal, non-directionaloptical smoke detector,24 V DC, for transom, linteland ceiling fixing. For use asa smoke switch and monitoringunit for hold-opendevices. A floating (volt-free)alarm contact and connectionsfor external manualrelease device are provided.Approved by the GermanInstitute for <strong>Building</strong>Technology, Berlin, for usein a hold-open system, andapproved by the VdS,Cologne, to EN 54, Part 7.Acceptance inspection ofthe system is mandatory.ColourY silverwhite, sim. to RAL Y 9010Y 9016Y stainless steelY polished brassY special colour (sim. to RAL)Make<strong>DORMA</strong> RM<strong>TS</strong> <strong>93</strong> GB33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!