10.07.2015 Views

TS 93 DORMA - The Building Product Directory

TS 93 DORMA - The Building Product Directory

TS 93 DORMA - The Building Product Directory

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>DORMA</strong> G-EMFSlide channel assemblyElectro-mechanical hold-open51842830120°80°34Hold open range= Door stop<strong>The</strong> <strong>DORMA</strong> G-EMF slidechannel assembly enablesthe door to be held opensecurely at a preselectedposition without fall-back.<strong>The</strong> hold-open point can beadjusted within an openingangle of approx. 80° and 120°.Note<strong>The</strong> active leaf can be openedup to the maximum selectedhold-open point (door stopto be positioned accordingly).In the event of an alarm ora fault in the power supply,the hold-open is releasedand the door is closed bythe door closer. <strong>The</strong> releaseis triggered by a signal fromexternal smoke detectors(e.g. <strong>DORMA</strong> RMZ or<strong>DORMA</strong> RM).<strong>The</strong> release force for thehold-open mechanism canbe adjusted without toolsand is rated to ensure thatthe door can also be easilyreleased manually.<strong>The</strong> <strong>DORMA</strong> G-EMF slidechannel assembly comprisesthe slide arm, slide channel,slide block, electro-mechanicalhold-open unit, cover,fixing screws and end caps.<strong>The</strong> <strong>DORMA</strong> G-EMFis transom-fixed and nonhanded.In the case of particularlylarge and heavy doors (over1250 mm), or doors inwhich the hold-open pointrequired exceeds 120°, werecommend that <strong>DORMA</strong> EMhold-open magnets inconjunction with the<strong>DORMA</strong> RMZ central smokedetector be employed insteadof the electro-mechanicalhold-open unit.Technical dataOperating voltage 24 vDC, ± 15%Power input1.4 WRated for continuous duty (100%)Release forceadjustablemax. 1699 428l 8 (24 V DC)16426544311,584 (80)8142160( ) = <strong>TS</strong> <strong>93</strong> 5 – 7<strong>DORMA</strong> <strong>TS</strong> <strong>93</strong> B closer with <strong>DORMA</strong> G-EMF slide channel assembly, pull-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.max. 264289911,5l 8 (24 V DC)8543811728( ) = <strong>TS</strong> <strong>93</strong> 5 – 716043(45)49107<strong>DORMA</strong> <strong>TS</strong> <strong>93</strong> G closer with <strong>DORMA</strong> G-EMF slide channel assembly, push-side fixingExample: Anticlockwise-closing (ISO 6) door; mirrored arrangements apply to clockwise-closing (ISO 5) doors.10<strong>TS</strong> <strong>93</strong> GB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!