Terra heat pumps may only be installed by competent<br />
specialist staff and commissioned and serviced by a<br />
customer service company trained to do so by IDM-<br />
Energiesysteme GmbH.<br />
Service and repair work must also be undertaken by a<br />
company customer service company trained to do so<br />
by IDM- Energisysteme GmbH.<br />
Switching the system on and off:<br />
Including in emergencies, the main switch at the top<br />
of the heat pump, or in the case of CL heat pumps<br />
by using the main switch on the independent control<br />
cabinet, is used to switch the system on and off.<br />
Safety of operation can no longer be guaranteed if the<br />
equipment<br />
- Has visible damage<br />
- No longer operates<br />
- Repetitive error warnings are displayed.<br />
Should this be the case, the equipment must be shut<br />
down, secured against unintentional operation and<br />
customer service informed.<br />
In the event of an error, the heat pump is automatically<br />
switched off. The Navigator Control display issues an<br />
error warning. (see Chapter 7).<br />
Terra SW main switch<br />
Terra CL main switch<br />
Operating Instructions<br />
Refrigerant:<br />
Refrigerant used: □ R407C<br />
□ R134A<br />
In the event of any required repairs, no other refrigerant<br />
should be used.<br />
Refrigerant fi lling weight: ________ kg<br />
Maximum operating pressure: 27 bar<br />
Safety instructions for the refrigerant:<br />
Rapid evaporation of the refrigerant can cause frost<br />
damage.<br />
Refrigerant vapours are heavier than air and, due to<br />
atmospheric oxygen deprivation, can lead to suffocation.<br />
Therefore, in the event of an incident, it must be<br />
ensured that the installation room is well ventilated.<br />
First aid measures:<br />
General instructions: in the case of unconsciousness,<br />
place the person on their side and seek medical assistance.<br />
Never administer anything into the mouth<br />
of an unconscious person. Use artifi cial respiration in<br />
the event of uneven breathing or respiratory standstill.<br />
Should diffi culties persist, consult a doctor.<br />
Inhalation:<br />
Go out in the fresh air. Keep the affected person in<br />
a warm and quiet place. Artifi cial respiration and/or<br />
oxygen may be required.<br />
Contact <strong>with</strong> the skin:<br />
Wash off <strong>with</strong> warm water. Immediately remove soiled,<br />
impregnated clothing.<br />
Contact <strong>with</strong> the eyes:<br />
Immediately rinse <strong>with</strong> lots of water, including under<br />
the eyelids. Consult a doctor.<br />
If any of the housing parts are removed<br />
this can lead to the risk of injury from an<br />
electric shock and hot surfaces.<br />