TERRA HGL/BA with

TERRA HGL/BA with TERRA HGL/BA with

11.08.2012 Views

1 2 3 4 5 6 7 8 9 10 11 12 13 Contents 2. Allgemeine Beschreibung Contents 2 General instructions on operating the heat pump. Important instructions on assembling and operating the heat pump. It is imperative that these are observed. All rights reserved for modifi cations to the technology and design. Operating Manual NAV 1.0 T HE POWER FAMILY OPERATING INSTRUCTIONS 3 1. DESCRIPTION 4 1.1. General information 4 1.2. Navigator Control for HGL Technology 5 1.3. Structure of the Navigator Control 5 2. OPERATION 6 2.1. Operation using the Control Unit 6 2.2. Displays in the Main Menu 6 2.3. Displays in the Status Bar 7 3. OPERATING MODES 8 3.1. Operating Modes via the Main Menu 8 4. TEMPERATURE SETTINGS 11 4.1. Temperature Settings via the Main Menu 11 5.1. Time Settings via the Main Menu 13 5. TIME SETTINGS 13 6. INFORMATION 18 6.1. Information via the Main Menu 18 7. ERRORS 20 7.1. Error Display in the Main Menu 20 General instructions on assembling the heat pump. Space for customer service telephone number (C) IDM ENERGIESYSTEME GMBH

T HE POWER FAMILY Terra heat pumps may only be installed by competent specialist staff and commissioned and serviced by a customer service company trained to do so by IDM- Energiesysteme GmbH. Service and repair work must also be undertaken by a company customer service company trained to do so by IDM- Energisysteme GmbH. Switching the system on and off: Including in emergencies, the main switch at the top of the heat pump, or in the case of CL heat pumps by using the main switch on the independent control cabinet, is used to switch the system on and off. Safety of operation can no longer be guaranteed if the equipment - Has visible damage - No longer operates - Repetitive error warnings are displayed. Should this be the case, the equipment must be shut down, secured against unintentional operation and customer service informed. In the event of an error, the heat pump is automatically switched off. The Navigator Control display issues an error warning. (see Chapter 7). Terra SW main switch Terra CL main switch Operating Instructions Refrigerant: Refrigerant used: □ R407C □ R134A In the event of any required repairs, no other refrigerant should be used. Refrigerant fi lling weight: ________ kg Maximum operating pressure: 27 bar Safety instructions for the refrigerant: Rapid evaporation of the refrigerant can cause frost damage. Refrigerant vapours are heavier than air and, due to atmospheric oxygen deprivation, can lead to suffocation. Therefore, in the event of an incident, it must be ensured that the installation room is well ventilated. First aid measures: General instructions: in the case of unconsciousness, place the person on their side and seek medical assistance. Never administer anything into the mouth of an unconscious person. Use artifi cial respiration in the event of uneven breathing or respiratory standstill. Should diffi culties persist, consult a doctor. Inhalation: Go out in the fresh air. Keep the affected person in a warm and quiet place. Artifi cial respiration and/or oxygen may be required. Contact with the skin: Wash off with warm water. Immediately remove soiled, impregnated clothing. Contact with the eyes: Immediately rinse with lots of water, including under the eyelids. Consult a doctor. If any of the housing parts are removed this can lead to the risk of injury from an electric shock and hot surfaces. (C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 3 1 2 3 4 5 6 7 8 9 10 11 12 13 Operating Instructions

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

Contents<br />

2. Allgemeine Beschreibung<br />

Contents<br />

2<br />

General instructions on operating the heat<br />

pump.<br />

Important instructions on assembling and<br />

operating the heat pump. It is imperative<br />

that these are observed.<br />

All rights reserved for modifi cations to the technology and design.<br />

Operating Manual NAV 1.0<br />

T HE POWER FAMILY<br />

OPERATING INSTRUCTIONS 3<br />

1. DESCRIPTION 4<br />

1.1. General information 4<br />

1.2. Navigator Control for <strong>HGL</strong> Technology 5<br />

1.3. Structure of the Navigator Control 5<br />

2. OPERATION 6<br />

2.1. Operation using the Control Unit 6<br />

2.2. Displays in the Main Menu 6<br />

2.3. Displays in the Status Bar 7<br />

3. OPERATING MODES 8<br />

3.1. Operating Modes via the Main Menu 8<br />

4. TEMPERATURE SETTINGS 11<br />

4.1. Temperature Settings via the Main Menu 11<br />

5.1. Time Settings via the Main Menu 13<br />

5. TIME SETTINGS 13<br />

6. INFORMATION 18<br />

6.1. Information via the Main Menu 18<br />

7. ERRORS 20<br />

7.1. Error Display in the Main Menu 20<br />

General instructions on assembling the heat<br />

pump.<br />

Space for customer service<br />

telephone number<br />

(C) IDM ENERGIESYSTEME GMBH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!