Temperature Settings<br />
4. Allgemeine Beschreibung<br />
Temperature Settings<br />
Heating circuit temperatures parameters<br />
Par.<br />
No.<br />
Name Description<br />
12<br />
Operating Manual NAV 1.0<br />
T HE POWER FAMILY<br />
HC108 Heating limit For mixer and uncontrolled heating circuits a heating limit can be set in the user menu<br />
above which the heating mode is blocked.<br />
HC109 Room infl uence<br />
Above this outside temperature, no further heating demand is generated by the<br />
heating circuit. The heating limit is deactivated <strong>with</strong> the setting 0.<br />
The room infl uence factor shows to what extent the control system reacts to the room<br />
temperature.<br />
HC110 Heating curve<br />
If the room unit is assembled in a room affected by other heat sources (e.g. a tiled<br />
stove) a smaller proportion should be selected. The temperature of the room in which<br />
the room unit is assembled, also affects the heating of the other rooms.<br />
Note: Parameter is only visible in the case of confi gured room unit.<br />
Given the steepness of the characteristic heating curve, the relation of the outside<br />
temperature to the required fl ow temperature is established.<br />
HC150 Normal Cooling Room<br />
Temp.<br />
HC151 ECO Cooling Room<br />
Temp.<br />
2,6<br />
2,4<br />
2,2<br />
2<br />
The greater the steepness of the characteristic curve is set, the higher the fl ow<br />
temperature for the heating depending on the outside temperature as well as on the<br />
heating and cooling limits.<br />
Parameter for the desired room temperature during Normal Cooling mode.<br />
Parameter for the desired room temperature during ECO Cooling mode.<br />
HC153 Cooling fl ow Parameter for the desired cooling circuit fl ow temperature.<br />
HC154 Dew-point gap This shows the minimum temperature difference between the dew-point (room humidity<br />
sensor) and the set fl ow temperature.<br />
HC108 Cooling limit Below this outside temperature no further cooling demand is generated by the<br />
cooling circuit.<br />
1,8<br />
Outside temperature [°C]<br />
1,6<br />
1,4<br />
1,2<br />
1<br />
0,8<br />
0,6<br />
0,4<br />