T HE POWER FAMILY<br />

4.1. Temperature Settings via the Main Menu<br />

The temperatures for fresh water capture can be set<br />

using the second menu item in the main menu, as<br />

well as the temperatures for the individual heating<br />

circuits.<br />

4.1.1. Fresh water temperature setting<br />

Fresh water temperature parameters<br />

Par.<br />

No.<br />

Name Description<br />

4. Temperature Settings<br />

FW30 Fresh water temperature The fresh water temperature gives the set temperature for the tapwater capture.<br />

It is possible to carry out this setting over the temperature range from 35.00°C<br />

to 60.00°C. The desired set temperature is set using the arrow keys. The new<br />

temperature value is confi rmed by using the right-hand selection key.<br />

4.1.2. Heating circuits temperature setting<br />

The parameters that can be set for the heating circuit<br />

temperatures are in accordance <strong>with</strong> the machine<br />

confi guration. Only the setting parameters that are<br />

relevant <strong>with</strong> regard to the machine confi guration are<br />

displayed.<br />

Heating circuit temperatures parameters<br />

Par.<br />

No.<br />

Name Description<br />

HC104 Normal Heating Room<br />

Temp.<br />

HC105 ECO Heating Room<br />

Temperature<br />

Upon delivery of the equipment, the default value is set at 46.00°C.<br />

Note: 60°C is only possible for heat pumps using the refrigerant R134a.<br />

The Normal Heating Room Temperature can be set between 15.00°C and 30.00°C.<br />

The duration during which the temperature is maintained depends on the respective<br />

heating program.<br />

The ECO Heating Room Temperature gives the temperature outside the selected<br />

heating times.<br />

The ECO Heating Room Temperature can be set between 10.00°C and 25.00°C.<br />

(C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 11<br />