TERRA HGL/BA with
TERRA HGL/BA with
TERRA HGL/BA with
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
T HE POWER FAMILY<br />
4.1. Temperature Settings via the Main Menu<br />
The temperatures for fresh water capture can be set<br />
using the second menu item in the main menu, as<br />
well as the temperatures for the individual heating<br />
circuits.<br />
4.1.1. Fresh water temperature setting<br />
Fresh water temperature parameters<br />
Par.<br />
No.<br />
Name Description<br />
4. Temperature Settings<br />
FW30 Fresh water temperature The fresh water temperature gives the set temperature for the tapwater capture.<br />
It is possible to carry out this setting over the temperature range from 35.00°C<br />
to 60.00°C. The desired set temperature is set using the arrow keys. The new<br />
temperature value is confi rmed by using the right-hand selection key.<br />
4.1.2. Heating circuits temperature setting<br />
The parameters that can be set for the heating circuit<br />
temperatures are in accordance <strong>with</strong> the machine<br />
confi guration. Only the setting parameters that are<br />
relevant <strong>with</strong> regard to the machine confi guration are<br />
displayed.<br />
Heating circuit temperatures parameters<br />
Par.<br />
No.<br />
Name Description<br />
HC104 Normal Heating Room<br />
Temp.<br />
HC105 ECO Heating Room<br />
Temperature<br />
Upon delivery of the equipment, the default value is set at 46.00°C.<br />
Note: 60°C is only possible for heat pumps using the refrigerant R134a.<br />
The Normal Heating Room Temperature can be set between 15.00°C and 30.00°C.<br />
The duration during which the temperature is maintained depends on the respective<br />
heating program.<br />
The ECO Heating Room Temperature gives the temperature outside the selected<br />
heating times.<br />
The ECO Heating Room Temperature can be set between 10.00°C and 25.00°C.<br />
(C) IDM ENERGIESYSTEME GMBH Operating Manual NAV 1.0 11<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
Temperature Settings