10.07.2015 Views

BATCHFLUX 5500 C - Forbes Marshall

BATCHFLUX 5500 C - Forbes Marshall

BATCHFLUX 5500 C - Forbes Marshall

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2 TECHNICAL DATA<strong>BATCHFLUX</strong> <strong>5500</strong> C2.1 Technical data• The following data is provided for general applications. If you require data that is morerelevant to your specific application, please contact us or your local representative.• Additional information (certificates, special tools, software,...) and complete productdocumentation can be downloaded free of charge from the website (Download Center).Measuring systemMeasuring principleApplication rangeMeasured valuePrimary measured valueSecondary measured valueFaraday's lawElectrically conductive fluidsFlow velocityVolume flowDesignFeaturesTube: Zirconium oxide (DN2.5...15) / Aluminium oxide (DN25...40)Electrodes: Fused-in cermet (DN2.5...15) / Platimum (DN25...40)Standard wet calibrationModular constructionThe measurement system consists of a flow sensor and a signalconverter. It is only available as compact version.Compact version<strong>BATCHFLUX</strong> <strong>5500</strong> CNominal diameterDN2.5...40 / 0.1...1½"Measurement range -12...+12 m/s / -39...+39 ft/sUser interfaceOperating dataFactory set to customer specification.Human Machine Interface (HMI) Option: BATCHMon Plus softwareCable connections1x M12, 5-pin connector8www.krohne.com03/2010 - 4000043102 - TD <strong>BATCHFLUX</strong> <strong>5500</strong> R02 en

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!