Application Report - Rohmann GmbH
Application Report - Rohmann GmbH
Application Report - Rohmann GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Application</strong> <strong>Report</strong><br />
Inspection on Components for Wind Energy Systems<br />
Complete assembled parts<br />
The parts are from non-conductive material. There are rings made from aluminium or<br />
copper inside the parts. The distance between these rings should be about 14mm. It<br />
should be checked whether the distance is not less than 8 mm. ABB in Spain use the<br />
ELOTEST M2V3 with a PKA 48-23 probe for this application.<br />
Also the new ELOTEST M3 and the ELOTEST B310 can be used for this application.<br />
Sample part – complete view with Elotest M3:<br />
Sample part – defect view:<br />
<strong>Rohmann</strong> <strong>GmbH</strong> • Carl-Benz-Str. 23 • 67227 Frankenthal • GERMANY • Tel. +49(0)62 33 - 3789-0 • Fax +49(0)62 33 - 3789-77 • www.rohmann.de • E-Mail: info@rohmann.de<br />
<br />
Distance too small<br />
<strong>Rohmann</strong> <strong>GmbH</strong><br />
<br />
<br />
<strong>Application</strong> <strong>Report</strong><br />
Sample part with probe PKA 48-23: Drawing:<br />
The probe is moved along the surface <br />
<br />
Screendump with the eddy current signal from<br />
the sample part:<br />
Distance Distance too too small<br />
small <br />
Distance Distance too too small<br />
small <br />
<br />
<br />
Test systems and accessories:<br />
<strong>Rohmann</strong> <strong>GmbH</strong> • Carl-Benz-Str. 23 • 67227 Frankenthal • GERMANY • Tel. +49(0)62 33 - 3789-0 • Fax +49(0)62 33 - 3789-77 • www.rohmann.de • E-Mail: info@rohmann.de<br />
<br />
<strong>Rohmann</strong> <strong>GmbH</strong><br />
ELOTEST M3<br />
The new ELOTEST M3 is unbeatable anytime a high resolution is required, when<br />
diffificult jobs are to be done or when both hands are required and the instrument<br />
has to be put down or when several inspectors have to look at the display at the<br />
same time.<br />
Yet the typical performance data are quite impressive:<br />
• Full frequency range from 10Hz to 12MHz<br />
• All filter functions (low pass, high pass, band pass)<br />
(optimized special filters for rotor operation)<br />
• Wide amplification range<br />
• Dual-frequency operation; may be independently<br />
adjusted (1 probe)<br />
• Pictograph-guided operation via 10 keys (dual<br />
compensation)<br />
• All commercially available probes may be connected<br />
Probe PKA 48-23<br />
Frequency: 80 Hz - 8 kHz<br />
Order number: ASP07330