<strong>Application</strong> <strong>Report</strong><br />

Inspection on Components for Wind Energy Systems<br />

Complete assembled parts<br />

The parts are from non-conductive material. There are rings made from aluminium or<br />

copper inside the parts. The distance between these rings should be about 14mm. It<br />

should be checked whether the distance is not less than 8 mm. ABB in Spain use the<br />

ELOTEST M2V3 with a PKA 48-23 probe for this application.<br />

Also the new ELOTEST M3 and the ELOTEST B310 can be used for this application.<br />

Sample part – complete view with Elotest M3:<br />

Sample part – defect view:<br />

<strong>Rohmann</strong> <strong>GmbH</strong> • Carl-Benz-Str. 23 • 67227 Frankenthal • GERMANY • Tel. +49(0)62 33 - 3789-0 • Fax +49(0)62 33 - 3789-77 • www.rohmann.de • E-Mail: info@rohmann.de<br />


<br />

Distance too small<br />

<strong>Rohmann</strong> <strong>GmbH</strong><br />


<br />



<br />

<strong>Application</strong> <strong>Report</strong><br />

Sample part with probe PKA 48-23: Drawing:<br />


 The
probe
is
moved
along
the
surface
<br />


<br />

Screendump with the eddy current signal from<br />

the sample part:<br />

Distance Distance
too
 too small<br />

small
<br />

Distance Distance
too
 too small<br />

small
<br />


<br />


<br />

Test systems and accessories:<br />

<strong>Rohmann</strong> <strong>GmbH</strong> • Carl-Benz-Str. 23 • 67227 Frankenthal • GERMANY • Tel. +49(0)62 33 - 3789-0 • Fax +49(0)62 33 - 3789-77 • www.rohmann.de • E-Mail: info@rohmann.de<br />


<br />

<strong>Rohmann</strong> <strong>GmbH</strong><br />

ELOTEST M3<br />

The new ELOTEST M3 is unbeatable anytime a high resolution is required, when<br />

diffificult jobs are to be done or when both hands are required and the instrument<br />

has to be put down or when several inspectors have to look at the display at the<br />

same time.<br />

Yet the typical performance data are quite impressive:<br />

• Full frequency range from 10Hz to 12MHz<br />

• All filter functions (low pass, high pass, band pass)<br />

(optimized special filters for rotor operation)<br />

• Wide amplification range<br />

• Dual-frequency operation; may be independently<br />

adjusted (1 probe)<br />

• Pictograph-guided operation via 10 keys (dual<br />

compensation)<br />

• All commercially available probes may be connected<br />

Probe PKA 48-23<br />

Frequency: 80 Hz - 8 kHz<br />

Order number: ASP07330