10.07.2015 Views

Product Catalog

Product Catalog

Product Catalog

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Energy Controls-40°F(-40°C)to155°F(68°C)DTMV40DTMV40-MMechanism OnlyDTMV40-BBracket MountCompliantE10694UL916E76987HVAC/R Multi-VoltageDefrost ControlsDTMV40 SeriesMulti-Voltage Time SwitchHVAC/RMechanical time switches designed for defrost control ofrefrigeration equipment, stand-up coolers and freezer cases.Multi-voltage feature reduces the need to stock additional SKUs. Simply snaps intoexisting enclosures. Replaces over 40 competitive SKUs.<strong>Product</strong> Features:• 40 Amp rated contacts• Captive trippers are independently adjustable for full or partial defrost cycles in 15minute intervals• Time initiated, temperature, pressure or time-terminated• “Real time” clock face for quick, easy and accurate setting• Field adjustable multi-voltage DIP switch for 120, 208, 240 Volts• Multi-voltage feature reduces the need to stock additional SKUs• Red and green LED lights indicate defrost or refrigeration cycle• Available in a Quartz model with 7-day battery back-up (DTQMV)• NEMA 3R standard outdoor enclosure (DTMV40 ONLY)• All-in-one assembly• UL94HB Flame Class Rated• Electrically isolatedApplications:• Restaurants • Refrigeration Equipment • Supermarkets• Stand-up Coolers • Bars • Freezer Cases• Schools, Universities • Food Industry Refrigeration • Hotels• Convenience Stores • HospitalsSpecifications:Indoor/Outdoor Enclosure: NEMA 3R raintight enclosure, Gray with lockable hasp8.8 in. (22.0 cm) H x 6.6 in. (16.5 cm) W x 2.9 in. (7.3 cm) DBattery Back-up: Quartz drive model allows for 7 day battery back-upTemperature Range: -40°F (-40°C) to 131°F (55°C)Min ON/OFF Time: 15 minutesMax ON/OFF Time: 23 hours 45 minutesWiring Connections: Large screw terminals and ground lug terminationWire Size: AWG #8Shipping Weight: 3.0 lbs (1.36 kg)ELECTRICAL RATINGS:• 40 Amp Resistive, 120, 208, 240 VAC• 1 HP (16 FLA, 90 LRA) 120 VAC; 2 HP (12 FLA, 52 LRA) 240 VAC• “F” Terminal: 30 Amp Resistive, 120/240 VAC; 1 HP, 120 VAC; 2 HP, 240 VACDefrostBattery Frequency DefrostModel # Voltage Enclosure Backup No./Day DurationDTMV40 120, 208, 240 VAC, NEMA 3R No 1 to 24 15 – 18060 Hz MinutesDTMV40-M 120, 208, 240 VAC, Mechanism No 1 to 24 15 – 18060 Hz only MinutesDTMV40-B 120, 208, 240 VAC, Bracket No 1 to 24 15 – 18060 Hz Mount MinutesDTQMV40 120, 208, 240 VAC, NEMA 3R Yes 1 to 24 15 – 18060 Hz MinutesDTQMV40-M 120, 208, 240 VAC, Mechanism Yes 1 to 24 15 – 18060 Hz only MinutesDTQMV40-B 120, 208, 240 VAC, Bracket Yes 1 to 24 15 – 18060 Hz Mount Minutes20www.intermatic.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!