Product Catalog
Product Catalog
Product Catalog
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Energy ControlsT7401BT7401BRT2005C22.2-177 ModelsLR3730 withoutUL917 carryover8 lbs3.6 kgModelswithcarryover9 lbs4.1 kg-40°F(-40°C)to130°F(54°C)MechanicalTime SwitchesT7000B Series7-Day Timers with and without Carryover• Provide different ON/OFF program each day of the week• Provides true 7-day load control with minimum ON/OFF time of 3 1 ⁄2hours• Provide for 4 pole single throw and 4 pole (2NO/2NC) switching• Separate clock motor terminals for switching loads not on-line voltageApplications:• Heating • Air Conditioning • Pumps • Indoor Lighting• Outdoor Lighting • Motors • Signs • Billboards• Ventilating Systems • Fans • Filters • 3 Phase LoadsSpecifications:Enclosure: NEMA 1 Rated Indoor steel in gray finish w/separate grounding terminal.12 1 ⁄2 in. (31.7 cm) H x 8 1 ⁄4 in. (21.0 cm) W x 4 in. (10.2 cm) DKnockouts: Combination 1 ⁄2 – 3 ⁄4 in. nominal knockouts, two on back, one on each sideand two on bottom. Also one 1 in. nominal on bottom center.Outdoor Enclosure: Same as above with gasketsReplacement Motors: See page 158 for available clock motors.Switch Rating: Each Pole 40 Amp Resistive, 120-480 VAC; 40 Amp Tungsten,Inductive or 1000 VA Pilot Duty, 120-277 VAC; 2 HP (24 FLA) 120 VAC; 5 HP (28 FLA)240 VAC single phase; 7 1 ⁄2 HP (28 FLA) 208 VAC 3-phase; 10 HP (28 FLA) 240 VAC3-phase.Carryover: Models with BC suffix only. Minimum time – mechanical operation: 16hours. Carryover accuracy +/-2%.ClockModel# Model # Model MotorSteel Indoor Steel Outdoor with Volts AC AmpsEnclosure Enclosure B † Carryover Switch 60 Hz (per pole)T7401B T7401BR T7401BC 4PST 125 40T7402B T7402BC 4PST 208, 277 40T7801B T7801BC 2NO/2NC 125 40T7802B 2NO/2NC 208, 277 40* All models (suffix B) have separate clock motor terminals for switching circuits noton line voltage.For additional trippers (7 ON/7 OFF per pack), order No. 156T2548A.† See pages 46 and 47 for details.T2000 SeriesCompact 7-Day TimersHVAC/RFeatures:• Minimum ON/OFF time 2 hours• Up to 84 (42 ON/OFF) operations each weekSpecifications:Enclosure: NEMA 1 Indoor steel; see page 46Replacement Motors: See page 158 for available clock motors.Switch Rating: 20 Amp Resistive, 120 and 208-277 VAC; 1 ⁄2 HP, 120 VAC; 1 HP, 240VACClock MotorModel # Switch Volts AC 60 Hz AmpsT2005 SPDT 120 20T2006 SPDT 208, 277 20For additional trippers (12 per pack), order No. 156T1950A.For replacement Snap Switch order No. 133T701A.16www.intermatic.com