<strong>Service</strong> <strong>Instructions</strong> BZFM Stromag DessauIP 54safety in motionElectromagnetic Double - Face Spring-Applied Brake 12.12.2006bridgeU~inputvoltageU-brakeU~inputvoltagebridgeU brakefigure 5a one way rectification Figure 5b bridge rectificatione.g. with type EGV 500 e.g. with type BG 2704.4.1. Installation of the rectifierThe rectifier module can be mounted in the terminal box of the motor eg. as shown in figure 6figure 601 terminal block03 mounting screw04 contact bridgeTable 7The terminal contacts are assigned as follows:Contact Symbols Assignment of contactsK1 ; K2 ∼ ; ~ AC supply (K1 – phase conductor;K2 - N / PEN)K3 ; K4 - ; + DC output brakeK5 ; K6Auxiliary contact connection (only withDC –side switching)13