10.07.2015 Views

Thermal Performance: Part L1A - Masonryfirst.com

Thermal Performance: Part L1A - Masonryfirst.com

Thermal Performance: Part L1A - Masonryfirst.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Thermal</strong> <strong>Performance</strong>: <strong>Part</strong> <strong>L1A</strong><strong>Thermal</strong> properties of walls and floorsFigure 12 provides thermal performance information for a range of wall and floor constructions. U-valuesand thermal mass-related information is also included [18]. For a brief overview of all the thermal propertiesinformation in Figure 12, see page 21.Figure 12: <strong>Thermal</strong> properties for a range of walls, floors and partitions.<strong>Part</strong>ial fill, brick and aircrete block<strong>Part</strong>ial fill, brick andlightweight aggregate block<strong>Part</strong>ial fill, aircrete block (both leafs)External WallsPhenolic insulation Phenolic insulation Phenolic insulationU-values (W/m 2 K) U-values (W/m 2 K) U-values (W/m 2 K)0.28 303 mm wall / 50 mm insulation 0.28 308 mm wall / 55 mm insulation 0.28 298 mm wall / 40 mm insulationInsulation0.25 308 mm wall / 55 mm insulation 0.25 318 mm wall / 65 mm insulation 0.25 303 mm wall / 45 mm insulation0.20 328 mm wall / 75 mm insulation 0.20 338 mm wall / 85 mm insulation 0.20 328 mm wall / 70 mm insulation0.18 343 mm wall / 90 mm insulation 0.18 348 mm wall / 95 mm insulation 0.18 338 mm wall / 80 mm insulation0.15 368 mm wall / 115 mm insulation 0.15 373 mm wall / 120 mm insulation 0.15 358 mm wall / 100 mm insulationk-values (kJ/m 2 K) k-values (kJ/m 2 K) k-values (kJ/m 2 K)Wet plaster finish 65 Wet plaster finish 141 Wet plaster finish 65Plasterboard finish 52 Plasterboard finish 114 Plasterboard finish 52<strong>Thermal</strong> massOther thermal mass properties(wet plaster finish assumed)Other thermal mass properties(wet plaster finish assumed)Other thermal mass properties(wet plaster finish assumed)Admittance (W/m 2 K) 2.5 Admittance (W/m 2 K) 4.1 Admittance (W/m 2 K) 2.5Decrement values whenU-value is 0.2810 hours Decrement values whenU-value is 0.2810.3 hours Decrement values whenU-value is 0.2810.2 hoursFactor = 0.34 Factor = 0.25 Factor = 0.34Decrement values whenU-value is 0.1511.3 hours Decrement values when 11.6 hours Decrement values when 11.6 hoursU-value is 0.15U-value is 0.15Factor = 0.3 Factor = 0.23 Factor = 0.29Values contained in Figure 12 are intended for guidance purposes only.14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!