10.07.2015 Views

AXICO ANTI-STALL® Axial flow fan Fläkt

AXICO ANTI-STALL® Axial flow fan Fläkt

AXICO ANTI-STALL® Axial flow fan Fläkt

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

FPAC and FPMC axial-<strong>flow</strong> <strong>fan</strong>s Page 21Ordering key<strong>Axial</strong> <strong>flow</strong> <strong>fan</strong> (see note)<strong>Axial</strong> <strong>flow</strong> <strong>fan</strong> (see note)When placing the order, please state the max.blade angle in text (see point 11, page 11)TypeAC = pneumatic controlMC = mechanical controlArrangement (a)1 = Impeller mounted on motor shaftfor FPAC080 up to and incl. 125-5-d-e-f090 up to and incl. 125-6-d-e-ffor FPMC 080 up to and incl. 125-5-d-e-f090 up to and incl. 125-6-d-e-f3 = For belt-drive (belt drive to be ordered separately)for FPAC, FPMC 080-5-d-e-f090-6-d-e-f100-6-d-e-f112-6-d-e-f6 = Ducted <strong>fan</strong>Horizontal installation:for FPAC080 up to and incl. 125-5-d-e-f090 up to and incl. 180-6-d-e-f112 up to and incl. 180-8-d-e-f 1)for FPMC 080 up to and incl. 125-5-d-e-f090 up to and incl. 125-6-d-e-fVertical installation: 2)for FPAC080 up to and incl. 125-5-d-e-f090 up to and incl. 180-6-d-e-f112 up to and incl. 180-8-d-e-f7 = Impeller mounted on intermediate shaftfor FPAC080 up to and incl. 125-5-d-e-f090 up to and incl. 180-6-d-e-f112 up to and incl. 180-8-d-e-ffor FPMC 080 up to and incl. 125-5-d-e-f090 up to and incl. 160-6-d-e-fSize (bbb)080, 090, 100, 112, 125, 140, 160, 180Hub diameter (c)5 = 500 mm, 6 = 630 mm, 8 = 800 mmNumber of blades (d)Number of blades on size/hub8 = 8 blades on 080/5 - 125/5, 090/6 - 180/69 = 10 blades on 112/8 - 180/8Motor size (e) 3)0 = 132 S, M 5 = 250 M1 = 160 M, L 6 = 280 S, M2 = 180 M, L 7 = 315 S, M3 = 200 L 8 = 315 L4 = 225 S, M 9 = 355 S, MDesign (f)2 = all except FPAC-6, vertical3 = FPAC-6, vertical, upward air discharge4 = FPAC-6, vertical downward air dischargeGuide vane diffuser, CD-version (for FPAC)Guide vane diffuser, CD-version (for FPMC)Diffuser, short (after CD guide vane diffuser)Diffuser, long (after <strong>fan</strong>)Air distributor 4) (after <strong>fan</strong>)Air distributor 4) (after diffusers, se page 6)Transition piece(CD guide vane diffuser - air distributor)Size = bbb in <strong>fan</strong> ordering keyHub diameter = c in <strong>fan</strong> ordering keyFPAC-a-bbb-c-d-e-fFPMC-a-bbb-c-d-e-fFPAZ-01-bbb-cFPMZ-01-bbb-cFPAZ-02-bbb-cFPAZ-03-bbb-cFPAZ-04-bbb-cFPAZ-05-bbb-cFPAZ-06-bbb1) Motor with angular contact bearings (for thrust loading on motor) for size/hub dia. 160/8 - 180/82) Motor with angular contact bearings (for thrust loading on motor)for upward direction of air discharge. FPMC will be quoted on request.3) Check that the selected motor is included in the “Motors” table. See page 34.4) If ordered separately, the air diffusers can be supplied in split condition to facititate transport.Inlet with protective grille (only for arr. 6)Size = bbb in <strong>fan</strong> ordering keyCylindrical silencerSize = bbb in <strong>fan</strong> ordering keyDiameter of core (c)0 = without core5, 6, 8 = hub diameter = c in <strong>fan</strong> ordering keyAcoustic diffuser (with sound attenuation)Size = bbb in <strong>fan</strong> ordering keyHub diameter = c in <strong>fan</strong> ordering keyFlexible duct (for sound absorber)Size = bbb in <strong>fan</strong> ordering keyCounterflange (for diffuser outlet) *Grouting-in frame (for diffuser outlet) *Materials and finish (a)0 = unpainted, 1 = steel, paintedSize = bbb in <strong>fan</strong> ordering key. see * below* NB. The outlet of FPAZ-02, 03 and -25 diffusersis two sizes larger than the <strong>fan</strong> connection.ActuatorActuatorActuatorSee table on page 28Electro-pneumatic positionerPressure control equipmentControl range (bb): 05 = 0-500 Pa10 = 50-1000 Pa20 = 100-2000 PaVersion (c): 1 = For one <strong>fan</strong>2 = For two <strong>fan</strong>sPressure control equipmentControl range (bb): 05 = 0-500 Pa10 = 50-1000 Pa20 = 100-2000 PaVersion (c): 1 = For one <strong>fan</strong>2 = For two <strong>fan</strong>sType (d): 1 = Increase-Decrease2 = 2-10V DCFlow measurement transmitterFor particulars of the measuring range, get in touchwith your nearest Fläkt Woods AB representativeFlow measuring tappingb = code suffix “a” in the <strong>fan</strong> codeControl equipment for air <strong>flow</strong> controlControl range (bb): 05 = 0-500 Pa10 = 50-1000 Pa20 = 100-2000 PaBlade pitch indicator for FPACBlade pitch indicator for FPMCFPAZ-21-bbbFPAZ-24-bbb-cFPAZ-25-bbb-cFPAZ-33-bbbEBGA-a-bbbEBGV-a-bbbFPMZ-07-bFPMZ-09-bFPMZ-13-bFPAZ-14FPAZ-16-bb-cFPMZ-16-bb-c-dFPAZ-17FPAZ-18-bbFPAZ-70-bbFPAZ-19FPMZ-19NoteThe motor should be specified separately as described on pages 34-39.The <strong>fan</strong>s are designed for being driven by ABB motors, but a quotation can besubmitted for equipping the <strong>fan</strong> with a motor of any other manufacture. However, ifa different motor is selected, the order must always be accompanied by a drawingshowing the dimensions of the relevant motor.In the case of arrangements 1 and 6, the outside dimensions of the motor mustnot be larger than those of the corresponding ABB motor, and the thrust-carryingcapacity of the bearings must not be lower. For arrangements 1 and 6 the outsidedimensions of the motor must not be larger than the hub diameter of thecorresponding <strong>fan</strong>, since the <strong>fan</strong> performance may otherwise be affected.This applies to motor sizes IEC 225, 250 and 280 for hub diameters 5, 6 and 8respectively. For arrangement 6, sizes 280 and larger motors must havepermanently connected cables without terminal box in accordance with FläktWoods AB drawing no. V 2608656.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!