FPAC and FPMC axial-<strong>flow</strong> <strong>fan</strong>s Page 20140012000<strong>AXICO</strong> <strong>ANTI</strong>-STALL ® q, m³/h x 10002040 60 80 100 120 140 160 180 200 220 240FPAC, FPMC 180-8-9n = 980 rpm119 L wti30000<strong>AXICO</strong> <strong>ANTI</strong>-STALL ® q, m³/h x 1000100 200 300 400FPAC, FPMC 180-8-9n = 1470 rpm128 L wtiD pt , PaP, kWD p , Pa100080060040020000020406080CD20°1020°203070PdiPdDi80q, m³/s100J = 16.4 kgm²i1200 20 30 40 50 60 70 q, m³/s2025°25°8280767030°30°h t= 84.5%844010735°35°10940°50 6040°11311145°45°11711550 100 150 200 250 300 400 50052°50°50°52°D P 1D pt , PaP, kWD p , Pa20001000000100200300CD20°2020°40100PdiPdDi120q, m³/sJ = 16.4 kgm²i4000 40 60 80 100 q, m³/s5025°25°8280767030°30°h t= 84.5%846011635°35°8011840°40°12212045°45°100 200 300 400 500 100012612452°50°50°52°D P 1CD2050 100 150 200 250 300 400D P 2CD50100 200 300 400 500 6001000D P 22050 100 150 200 250 300 350 400D P 350100 150 200 300 400 500600 700D P 3510 15 20 30 40 50 60 70D P 41020 30 50 100150200D P 4Motors, arrangements 1, 6 and 7 (to be ordered separately)FPACFPMCArrangement (a)Arrangement (a)1 6 7 1 6 7 Motor sizeSize Hub diameter (c) Hub diameter (c) as perbbb 5 6 8 5 6 8 5 6 8 5 6 5 6 5 6 IECx x x x x x 132 S, M080 x x x x x x 160 M, Lx x x x x x 180 Mx x x x x x x x x x x x 132 S, M090x x x x x x x x x x x x 160 M, Lx x x x x x x x x x x x 180M, Lx x x x x x x x x x x x 200 Lx x x x x x x x x x x x 160 M, L100x x x x x x x x x x x x 180 M, Lx x x x x x x x x x x x 200 Lx x x x x x x x x x x x 225 S, Mx x x x x x x x x x x x 160 M, Lx x x x x x x x x x x x x x x 180 M, Lx x x x x x x x x x x x x x x 200 L112 x x x x x x x x x x x x x x x 225 S, Mx x x x x x x x x 250 Mx x x x x x 280 Sx x x 280 Mx x x x x x x x x x x x x 180 M, Lx x x x x x x x x x x x x x x 200 Lx x x x x x x x x x x x x x x 225 S125 x x x x x x x x x x x x x x x 225 Mx x x x x x x x x x x x x x x 250 Mx x x x x x x x x 280 S, Mx315 Sx x x x x 200 Lx x x x x x x 225 S, Mx x x x x x x 250 M140 x x x x x x x 280 S, Mx x x x x 315 S, M, Lx355 Sx x x x x 225 S, Mx x x x x x x 250 M160x x x x x x x 280 S, Mx x x x x 315 Sx x x 315 M, Lx355 Sx x x x 225 Sx x x x x 225 Mx x x x x x x 250 M180 x x x x x x x 280 S, Mx x x x x 315 S, M, Lx x x x 355 Sx355 MMotors, arrangement 3(to be ordered separately)Fan Motor MaxFPAC, FPMC size <strong>fan</strong>Size Hub as per speed,bbb c IEC r/min080 5 160M - 250M 2000090 6 180M - 280S 1900100 6 200L - 280M 1900112 6 225S - 315S 1800
FPAC and FPMC axial-<strong>flow</strong> <strong>fan</strong>s Page 21Ordering key<strong>Axial</strong> <strong>flow</strong> <strong>fan</strong> (see note)<strong>Axial</strong> <strong>flow</strong> <strong>fan</strong> (see note)When placing the order, please state the max.blade angle in text (see point 11, page 11)TypeAC = pneumatic controlMC = mechanical controlArrangement (a)1 = Impeller mounted on motor shaftfor FPAC080 up to and incl. 125-5-d-e-f090 up to and incl. 125-6-d-e-ffor FPMC 080 up to and incl. 125-5-d-e-f090 up to and incl. 125-6-d-e-f3 = For belt-drive (belt drive to be ordered separately)for FPAC, FPMC 080-5-d-e-f090-6-d-e-f100-6-d-e-f112-6-d-e-f6 = Ducted <strong>fan</strong>Horizontal installation:for FPAC080 up to and incl. 125-5-d-e-f090 up to and incl. 180-6-d-e-f112 up to and incl. 180-8-d-e-f 1)for FPMC 080 up to and incl. 125-5-d-e-f090 up to and incl. 125-6-d-e-fVertical installation: 2)for FPAC080 up to and incl. 125-5-d-e-f090 up to and incl. 180-6-d-e-f112 up to and incl. 180-8-d-e-f7 = Impeller mounted on intermediate shaftfor FPAC080 up to and incl. 125-5-d-e-f090 up to and incl. 180-6-d-e-f112 up to and incl. 180-8-d-e-ffor FPMC 080 up to and incl. 125-5-d-e-f090 up to and incl. 160-6-d-e-fSize (bbb)080, 090, 100, 112, 125, 140, 160, 180Hub diameter (c)5 = 500 mm, 6 = 630 mm, 8 = 800 mmNumber of blades (d)Number of blades on size/hub8 = 8 blades on 080/5 - 125/5, 090/6 - 180/69 = 10 blades on 112/8 - 180/8Motor size (e) 3)0 = 132 S, M 5 = 250 M1 = 160 M, L 6 = 280 S, M2 = 180 M, L 7 = 315 S, M3 = 200 L 8 = 315 L4 = 225 S, M 9 = 355 S, MDesign (f)2 = all except FPAC-6, vertical3 = FPAC-6, vertical, upward air discharge4 = FPAC-6, vertical downward air dischargeGuide vane diffuser, CD-version (for FPAC)Guide vane diffuser, CD-version (for FPMC)Diffuser, short (after CD guide vane diffuser)Diffuser, long (after <strong>fan</strong>)Air distributor 4) (after <strong>fan</strong>)Air distributor 4) (after diffusers, se page 6)Transition piece(CD guide vane diffuser - air distributor)Size = bbb in <strong>fan</strong> ordering keyHub diameter = c in <strong>fan</strong> ordering keyFPAC-a-bbb-c-d-e-fFPMC-a-bbb-c-d-e-fFPAZ-01-bbb-cFPMZ-01-bbb-cFPAZ-02-bbb-cFPAZ-03-bbb-cFPAZ-04-bbb-cFPAZ-05-bbb-cFPAZ-06-bbb1) Motor with angular contact bearings (for thrust loading on motor) for size/hub dia. 160/8 - 180/82) Motor with angular contact bearings (for thrust loading on motor)for upward direction of air discharge. FPMC will be quoted on request.3) Check that the selected motor is included in the “Motors” table. See page 34.4) If ordered separately, the air diffusers can be supplied in split condition to facititate transport.Inlet with protective grille (only for arr. 6)Size = bbb in <strong>fan</strong> ordering keyCylindrical silencerSize = bbb in <strong>fan</strong> ordering keyDiameter of core (c)0 = without core5, 6, 8 = hub diameter = c in <strong>fan</strong> ordering keyAcoustic diffuser (with sound attenuation)Size = bbb in <strong>fan</strong> ordering keyHub diameter = c in <strong>fan</strong> ordering keyFlexible duct (for sound absorber)Size = bbb in <strong>fan</strong> ordering keyCounterflange (for diffuser outlet) *Grouting-in frame (for diffuser outlet) *Materials and finish (a)0 = unpainted, 1 = steel, paintedSize = bbb in <strong>fan</strong> ordering key. see * below* NB. The outlet of FPAZ-02, 03 and -25 diffusersis two sizes larger than the <strong>fan</strong> connection.ActuatorActuatorActuatorSee table on page 28Electro-pneumatic positionerPressure control equipmentControl range (bb): 05 = 0-500 Pa10 = 50-1000 Pa20 = 100-2000 PaVersion (c): 1 = For one <strong>fan</strong>2 = For two <strong>fan</strong>sPressure control equipmentControl range (bb): 05 = 0-500 Pa10 = 50-1000 Pa20 = 100-2000 PaVersion (c): 1 = For one <strong>fan</strong>2 = For two <strong>fan</strong>sType (d): 1 = Increase-Decrease2 = 2-10V DCFlow measurement transmitterFor particulars of the measuring range, get in touchwith your nearest Fläkt Woods AB representativeFlow measuring tappingb = code suffix “a” in the <strong>fan</strong> codeControl equipment for air <strong>flow</strong> controlControl range (bb): 05 = 0-500 Pa10 = 50-1000 Pa20 = 100-2000 PaBlade pitch indicator for FPACBlade pitch indicator for FPMCFPAZ-21-bbbFPAZ-24-bbb-cFPAZ-25-bbb-cFPAZ-33-bbbEBGA-a-bbbEBGV-a-bbbFPMZ-07-bFPMZ-09-bFPMZ-13-bFPAZ-14FPAZ-16-bb-cFPMZ-16-bb-c-dFPAZ-17FPAZ-18-bbFPAZ-70-bbFPAZ-19FPMZ-19NoteThe motor should be specified separately as described on pages 34-39.The <strong>fan</strong>s are designed for being driven by ABB motors, but a quotation can besubmitted for equipping the <strong>fan</strong> with a motor of any other manufacture. However, ifa different motor is selected, the order must always be accompanied by a drawingshowing the dimensions of the relevant motor.In the case of arrangements 1 and 6, the outside dimensions of the motor mustnot be larger than those of the corresponding ABB motor, and the thrust-carryingcapacity of the bearings must not be lower. For arrangements 1 and 6 the outsidedimensions of the motor must not be larger than the hub diameter of thecorresponding <strong>fan</strong>, since the <strong>fan</strong> performance may otherwise be affected.This applies to motor sizes IEC 225, 250 and 280 for hub diameters 5, 6 and 8respectively. For arrangement 6, sizes 280 and larger motors must havepermanently connected cables without terminal box in accordance with FläktWoods AB drawing no. V 2608656.