10.07.2015 Views

Digital instruments and measuring transducers - Circutor

Digital instruments and measuring transducers - Circutor

Digital instruments and measuring transducers - Circutor

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>Applications1.- Display on the screen of the numericalvalue of one or more electricalparameters of a sub-panel, control processor determined unit.2.- Alarm system: acting on meters,sound <strong>and</strong>/or light devices, to carry outthe protection or notification operationswith a relay output .3.- Control system via software:• yVoltage control• yCurrent control• yFrequency control• yTemperature control• yControl of any process signal• yControl of harmonics• yTime controlM2-4


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> <strong>instruments</strong>DC series<strong>Digital</strong> indicator for panelmountingReferencesDC. VoltmeterMeasurement Scale Input Size Type CodeAC150, 300, 600 V acDirect: 600 VTransformer: Programmable48 x 48 DC 48 B V ac M2021072 x 72 DC 72 B V ac M20220DC10, 50, 200 V dcDirect: - 200 / +200VProcess: 0...10 V48 x 48 DC 48 B V dc M2021372 x 72 DC 72 B V dc M20223DC 600 V dc - 600 / 600 V48 x 48 DC 48 B V dc M2021472 x 72 DC 72 B V dc M20224DC60, 150, 200 mV dcDirect: - 200 mV / +200 mVShunt: .../60 mV, .../150 mV48 x 48 DC 48 B mV dc M2021772 x 72 DC 72 B mV dc M20227DC. AmmeterMeasurement Scale Input Size Type CodeAC... / 5 ADirect: 5 ATransformer: .../5 A48 x 48 DC 48 B A ac M2021172 x 72 DC 72 B A ac M20221AC... / 5 ADirect: 5 ATransformer: .../5 AAC 10 A Direct: 10 A72 x 72 DC 72 MD A ac (*) M2022A48 x 48 DC 48 B A ac M2021272 x 72 DC 72 B A ac M20222DC5, 20,200 mADirect: - 200 mV / +200 mVProcess: 0 or 4...20 mV48 x 48 DC 48 B A dc M2021572 x 72 DC 72 B A dc M20225DC 10 A Direct: 10 A48 x 48 DC 48 B A dc M2021672 x 72 DC 72 B A dc M20226(*) Output relay availableDC. Frequency meterMeasurement Scale Input Size Type CodeACHz < 100, 2 dec.Hz > 100, 1 dec.40...600 V48 x 48 DC 48 B Hz ac M2021872 x 72 DC 72 B Hz ac M20228M2-7


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> <strong>instruments</strong>DC series<strong>Digital</strong> indicator for panelmountingReferencesDC. TemperatureMeasurement Relays Input Size Type Code- - 200 ... +200 ºC 72 x 72 DC 72 TMP22 M20621ºC1 - 200 ... +200 ºC 72 x 72 DC 72 TMP22 - 1R M20623- - 200 ... +800 ºC 72 x 72 DC 72 TMP28 M206221 - 200 ... +800 ºC 72 x 72 DC 72 TMP28 - 1R M20624Coding tableM 2 X X X X 0 0 X XCodeInternalCodeAuxiliarypower supplyCurrent inputSt<strong>and</strong>ard (230 V) 0100 ... 120 V ac 1480 ... 500 V ac 418 ... 36 V dc 7St<strong>and</strong>ard (.../ 5 A) 0... / 1 A 1DimensionsConnectionsM2-8


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> <strong>instruments</strong>DH series<strong>Digital</strong> <strong>instruments</strong> for panelmountingDescription}}<strong>Digital</strong> unit designed to show the programmedvalue of an electrical variable or processsignal on a display, depending on type. Alsouseful for regulation if used with relay outputcards (alarms)}}Fully programmable: scale, transformationratio, alarm relays, communications, etc.}}Measurement of V, A, Hz <strong>and</strong> process signal(impulses, weight, temperature, pressure,etc).}}Measurement in true root mean square(TRMS), types in AC.}}Multitude of options with expansion modules}}4 high luminosity digits}}High accuracy}}Installation in 96 x 48 mm panel}}4 digit, high luminosityApplication}}The high luminosity 4-digit digital displayindicates the voltage, current, frequency, etc.<strong>and</strong> it can be used to define the alarms of thedifferent electrical parameters measured.}}Transducer display of measured parametersto analogue signal for PLCs}}Display <strong>and</strong> communication of measureddata via RS-485 / RS-232 bus for integrationinto software or PLC.FeaturesPower supply circuit 230 Vac (-15 ... +20%)Frequency4 V·A (without card), 7 V·A (with card)Consumption45...65 HzMeasurement circuitOvervoltage(permanent / during 10 s)1.2 U n/ 2 U nOverload(permanent / during 10 s)1.2 I n/ 5 I nMeasurement margin 2 .. 120 %No. of conversions per cycle 32DisplayDecimal placeScale excess indicator “- - - -”Seven 14 mm segments, redProgrammableInsulationTest voltage3 kV, 50 Hz, 1 minImpulse test 4 kV (1.2 / 50 s)Ambient conditionsStorage temperature -40 ... +70 ºCOperating temperature -10 ... +65 ºCAltitude2000 mBuild featuresBox materialABS V0, grey anthraciteDegree of protection Box <strong>and</strong> terminals: IP 20 / Front panel: IP 54Weight550 gSt<strong>and</strong>ardsIn A, C, P types: IEC 1010, IEC 348, IEC 664, VDE 0110, VDE 0435In other types: IEC 1010, IEC 348, IEC 664, EN 50081-1, EN 50082-1ReferencesDH96. Ammeter or VoltmeterMeasurement Parameters Range Scale Accuracy Display Type CodeDCA or V200 V dcor 200 mA200 mA or50,100, 200 V0.2 % ( ± 1 dig ) 4 digits DH 96 C M20411ACA or V600 Vacor ... / 5 A... / 5 A or 150,300, 600 V0.5 % ( ± 1 dig ) 4 digits DH 96 A M20412M2-9


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> <strong>instruments</strong>DH series<strong>Digital</strong> <strong>instruments</strong> for panelmountingReferencesDH96. AmmeterMeasurement Parameters Range / Scale Accuracy Display Type CodeAC A …10 A 0.5 % (± 1 dig) 4 digits DH 96 A (10 A) M20413DH96. Ammeter <strong>and</strong> voltmeter (with shunt .../60 mV)Measurement Parameters Range / Scale Accuracy Display Type CodeProgrammable: V <strong>and</strong> ADCA <strong>and</strong> VRange of V: 1 to 100 VRange of A: Withshunt .../60 mV0.2 % (± 1 dig) 4 digits DH 96 A V M2041C ** Expansion cards are not usedDH96. Measurement stationMeasurement Parameters Range Scale Accuracy Display Type CodeDCV, A, kW,kW·hRange of V: upto 800 V V dcRange of A:.../60 mVProgrammable:Selec. V: 100 /300 / 800 Vdc0,2 %( ± 1 dig. )4 digits DH 96 CPM M20419DH96. Universal process indicatorMeasurement Parameters RangeScaleAccuracy Display Type CodeDC -± 20 mA, ± 1 mA, ± 120mV, ± 500 mV, ± 10 V0,2 %( ± 1 dig. )4 digits DH 96 P M20415DH96. Frequency meter <strong>and</strong> tachometerMeasurement Parameters Range / Scale Accuracy Display Type Code- Hz, r / min 0.1 ... 20000 Hz - 5 digits DH 96 FT M20417DH96. Chonometer <strong>and</strong> impulse meterMeasurement Parameters Range / Scale Accuracy Display Type Code-S, min, h,No. impulsesProgrammable to measuretime <strong>and</strong> impulses- 5 digits DH 96 CT M20418DH96. TemperatureMeasurement Parameters Range / Scale Accuracy Display Type Code- ºCRTD sensor <strong>and</strong>thermocouple0.2 % ( ±1 dig ) 5 digits DH 96 TMP M2041EM2-10


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> <strong>instruments</strong>DH series<strong>Digital</strong> <strong>instruments</strong> for panel mountingDimensionsConnectionsDH96 - A / C / PDH96 - AV / CPMM2-11


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> <strong>instruments</strong>DH series<strong>Digital</strong> <strong>instruments</strong> for panel mountingConnectionsDH96 - FTDH96 - CTDH96 - TMPM2-12


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>DINDH series<strong>Digital</strong> <strong>instruments</strong> for panel mountingCOMPATIBILITY WITH DH 96 MODULESTypes C A AV WG CPM P FT CT TPM Code2 relays • • - • • • • • • M204214 relays • • - • • • • • • M204222 relays + RS-485 or RS-232 (Modbus/RTU) • • - • • • • • • M20423Analogue output 0 / 4...20 mA • • - • • • • • • M20425Analogue output 0 / 2..10 V • • - • • • • • • M20426RS-232 (Modbus/RTU) • • - • • • • • • M20427RS-485 (Modbus/RTU) • • - • • • • • • M20428Analogue output 0 / 4...20 mA + 2 relays • • - • • • • • - M20429Module 2 relaysDescriptionFeaturesRelayNominal AC CurrentMaximum voltageMaximum resistive loadInsulation resistance ( at 500 V dc)Contact - coil insulationContact - contact insulationSwitched8 A250 Vac2000 V·A>1000 M4 kV1 kVMechanical working life (No. of operations) >10 7Electrical working life (8 A; 250 V ac)(No. of operations)St<strong>and</strong>ards VDE 0435, VDE 0700, VDE 0110, VDE 0106>10 5Module 4 relaysDescriptionFeaturesRelayNominal AC CurrentMaximum voltageMaximum resistive loadInsulation resistance ( at 500 V dc)Contact - coil insulationContact - contact insulationSimple5 A250 V ac750 V·A>1000 MW2 kV750 V acMechanical working life (No. of operations) >20 x 10 6Electrical working life (8 A; 250 V ac)(No. of operations)>30 x 10 3St<strong>and</strong>ards UL 508, C22.2 no. 14, VDE 0435M2-13


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>DINDH series<strong>Digital</strong> <strong>instruments</strong> for panelmountingCommunications moduleDescription}}0 to 247 programmable peripherals}}Selection of peripheral number}}(only in RS-485)}}Selection of communication parameters:speed, parity <strong>and</strong> stop bitsFeaturesRS-232 ModuleRS-485 ModuleEDS Protection Up to 10 kVac Up to 2 kVacCommunication lines protected againstoverloads, short-circuit to earth30 V without damage -Protected against blockages Yes -Communication lines withthermal protection againstexcessive power dissipationConnection or disconnectionfrom the active network- Yes- YesSt<strong>and</strong>ards EIA RS-232 EIA RS-485Analogue output moduleDescription}}Output option:}}0 20 mA or 4 20 mA}}0 10 V or 2 10 V}}Range of programmable outputFeaturesResolutionMaximum load impedancefor current outputsMaximum load impedancefor voltage outputsInsulation between analogueoutputs <strong>and</strong> the power supplyInsulation between analogue<strong>and</strong> measurement outputsResponse time14 bits5005003 kV3 kV< 100 msRippling, in TRMS < 0,5 %Temperature coefficient 100 ppm / ºCSt<strong>and</strong>ards IEC 1010, IEC 529, IEC 801, EN 50081-2, EN 5002-2Auxiliary power supply module (DH96P)Description}}Selectable auxiliary voltage: 5, 10,}}15 Vdc}}Compatible with all modules}}(except for relays <strong>and</strong> communications)}}Power supply for 2 <strong>and</strong> 3 wire sensor}}0 / 4...20 mA}}Maximum power 1 V·AM2-14


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>DINDH series<strong>Digital</strong> <strong>instruments</strong> for panelmountingDescriptionCOMMUNICATIONSFeatures}}0 to 247 programmable peripherals}}Selection of instrument direction (only inRS-485)}}Selection of communication speed: 1200,2400, 4800, 9600 <strong>and</strong> 19200 bits/s}}Selection of parity: even, odd or no parity}}Selection of stop bits: 1 or 2COMMUNICATIONS FeaturesRS-232 ModuleRS-485 ModuleEDS Protection Up to 10 kV Up to 2 kVCommunication lines protected againstoverloads, short-circuit to earthCommunication lines withthermal protection againstexcessive power dissipationConnection or disconnectionfrom the active network30 V without damage -- Yes- YesFully protected against blockages Yes -St<strong>and</strong>ards EIA RS-232 EIA RS-485RELAYSFeatures}}Maximum or minimum alarm connection}}Selectable delay to alarm connection <strong>and</strong>disconnection, programmable between 1 <strong>and</strong>9 999 s}}Selectable hysteresis of between 1 <strong>and</strong>9999 points}}Alarm interlocking option}}Option of fail-safe relayRELAY Features2 Relays 4 RelaysNominal current 8 A 5AMaximum voltage250 VacMaximum resistive load 2 000 V·A 750 V·AInsulation resistance ( at 500 Vdc) > 1000Ω YesContact - coil insulation 4 kV 2 kVContact - contact insulation: 2 /4 relays 1 kV 750 VacMechanical working life (No. of operations) 10 7 20 x 10 6Electrical working life (8 A <strong>and</strong>250 V) (No. of operations)St<strong>and</strong>ards> 10 5 >30 x 10 4VDE 0435, VDE 0700,VDE 0110, VDE 0106UL 508,C22.2 no. 14, VDE 0435M2-15


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>DINDH series<strong>Digital</strong> <strong>instruments</strong> for panelmountingCommunications module + 2 relaysDescriptionANALOGUE OUTPUTFeatures}}Optional output programming: 0...20 mAor 4...20 mA}}Programmable output rangeANALOGUE OUTPUT FeaturesResolutionMaximum load impedance for current outputsMinimum load impedance for voltage outputsInsulation between analogue outputs <strong>and</strong> thepower supplyInsulation between analogue <strong>and</strong> measurementoutputsResponse time14 bits500 Ω500 Ω3 kV3 kV< 100 msRippling, in TRMS < 0,5 %Temperature coefficient 100 ppm / ºCSt<strong>and</strong>ards IEC 1010, IEC 529, IEC 801, EN 50081-2, EN 50082-2RELAYSFeatures}}Connection of alarm when maximum orminimum values are reached}}Alarm connection <strong>and</strong> disconnection delay,programmable between 1 <strong>and</strong> 9,999seconds}}Hysteresis can be selected between9,999 <strong>and</strong> 9999 points}}Optional alarm interlocking}}Optional fail-safe relay2 RELAY OUTPUT FeaturesMaximum voltage250 VacMaximum resistive load750 V·AInsulation resistance ( at 500 Vdc)> 1 000 MContact - coil insulation2 kVContact - contact insulation750 V acMechanical working life20 x 10 6 operationsElectrical working life (8 A <strong>and</strong> 250 V)> 30 x 10 3 operationsTemperature coefficient> 30 x 10 3 operationsSt<strong>and</strong>ards UL 508, C22.2, VDE 0435Coding tableM 2 X X X X 0 0 X XCodeAuxiliarypower supplyCurrent inputInternalCodeSt<strong>and</strong>ard (230 V) 0100 ... 120 V ac 1380 ... 400 V ac 3480 ... 500 V ac 418 ... 36 V dc 736 ... 72 V dc 840 ... 170 V dc 9St<strong>and</strong>ard (.../ 5 A) 0... / 1 A 1M2-16


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> indicatorRoyal series<strong>Digital</strong> indicator of variousparameters for panel or DIN railmountingDescription}}4 digits, high luminosity}}Measurement in true root mean square(TRMS)}}Measurement in 2 or 4 quadrants (powergenerated <strong>and</strong> consumed)}}Valid for single <strong>and</strong> three-phase systems}}2 built-in relay outputs}}Measurement of maximum <strong>and</strong> minimumvalues}}Fully programmableApplication}}Ideal for industrial environments, thanksto its compact <strong>and</strong> robust format}}Optional fail-safe operationFeaturesROYAL A4 ROYAL A4 -P ROYAL A3Power supply circuit 230 Vac (± 15 %)FrequencyConsumptionMeasurement circuitScopeAccuracyOvervoltage(permanent / during 10 s)Overload(permanent / during 10 s)ConsumptionFrequencyDisplay40 ... 70 Hz3 V·A20 ... 500 Vac... / 5 A0.5 % FE1.2 U n/ 2 U n1.2 I n/ 5 I n0.25 V·A40 ... 70 Hz4 digitsScale excess indicator “ --- “Ambient conditionsStorage temperature -25 ... +70 ºC -25 ... +80 ºCOperating temperature 0 ... +50 ºCRelative humidity-95% to 40 ºC with no condensationBuild featuresBox materialABS VO PlasticDegree of protection Box <strong>and</strong> terminals: IP 20 / Front panel: IP 52Weight170 gSt<strong>and</strong>ards IEC 1010, IEC 348, IEC 664, VDE 0435, VDE 0110ReferencesMeasurement Parameters Input <strong>Digital</strong> Size Fixing Type CodeAC V1n, V2n, V3n or V12, V23, V31 230 V p-N/ 400 V p-p2 relays 6 modules DIN rail ROYAL A3 M20332AC V, A, Hz, W, V·A, var, cos ϕ, MD, THD ... / 5 A 2 relays 6 modules DIN rail ROYAL A4 M20242AC V, A, Hz, W, V·A, var, cos ϕ, MD, THD ... / 5 A 2 relays 96 x48x38 Panel ROYAL A4 -P M20241M2-17


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> <strong>instruments</strong>ROYAL series<strong>Digital</strong> indicator of variousparameters for panel or DIN railmountingCoding tableM 2 X X X X 0 0 X XCodeAuxiliarypower supplyCurrent inputInternalCodeSt<strong>and</strong>ard (230 V) 0100 ... 120 V ac 1380 ... 400 V ac 3480 ... 500 V ac 418 ... 36 V dc 736 ... 72 V dc 840 ... 170 V dc 9St<strong>and</strong>ard (.../ 5 A) 0... / 1 A 1DimensionsConnectionsM2-18


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> <strong>instruments</strong>DM45 Series<strong>Digital</strong> indicator for DIN rail mountingDescription}}Electrical parameter indicator equipment}}Its design enables the installation of theunit on small panels}}It measures voltage, current, frequency<strong>and</strong> harmonic distortion, depending on thetype}}Fully sealed}}Fully programmable alarm relay}}Robust <strong>and</strong> compact}}Stores maximum <strong>and</strong> minimum valuesApplication}}Displays one or various electrical parametersof a sub-panel, control process or determinedmachine}}Alarm system: the unit's internal relay canact on contactors, sound <strong>and</strong>/or light devicesto carry out a protection or warning operation.FeaturesDM 45 V DM 45 A DM 45 AD DM 45 FPower supply circuit 230 Vac (± 10 %)Frequency40 ... 70 HzConsumption5 V·AMeasurement circuitScope 600 Vac ... / 5 Aac 30 Aac 10... 600 HzAccuracy+/- 0.5 % FE +/- 1 digitOvervoltage (permanent) 1.05 U n- - 1.05 U nOverload (permanent) - 1.2 I n-Consumption0.6 V·AFrequency10 ...600 HzDisplay4 digits with 7 segments, red colour+ 4 auxiliary LEDsAmbient conditionsStorage temperature - 40 ... + 70 ºCOperating temperature - 20 ... + 50 ºCRelative humidity5 ... 95 % non-condensingBuild featuresBox materialSelf-extinguishing ABS plasticDegree of protection Front panel: IP 54Weight170 gSt<strong>and</strong>ards IEC 1010, IEC 664, IEC/EN 62053-31Safety st<strong>and</strong>ardsIEC61010* Other possible auxiliary power supplies9..18 Vd.c. / 18...36 Vd.c. / 36...72 Vd.c.M2-19


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong><strong>Digital</strong> <strong>instruments</strong>DM45 series<strong>Digital</strong> indicator for DIN rail mountingReferencesDM. VoltmeterMeasurement Parameters Input Relay Type CodeAC V 30..0.600 V ac 1 DM 45 V M20901DM. AmmetersMeasurement Parameters Input Relay Type CodeAC A ... / 5 A 1 DM 45 A M20911AC A 30 A 1 DM 45 AD M20921DM. Frequency-meterMeasurement Parameters Input Relay Type CodeAC Hz 10 ... 600 Hz 1 DM 45 F M20931DM. Measurement stationsMeasurement Parameters Input Relay Type CodeAC V, A, Hz, THD 600 V / .../5 A / 10...600 Hz 1 DM 45 CM M20941AC V, A, Hz, THD 600 V c / 30 A / 10...600 Hz 1 DM 45 CMD M20951Coding tableM 2 X X X X 0 0 XCodeAuxiliarypower supplyInternalCodeSt<strong>and</strong>ard (230 V) 0100 ... 115 V ac 118 ... 36 V dc 7DimensionsConnectionsM2-20


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>CMM 96<strong>Digital</strong> three-phase measurementstation for panel mountingDescription}}Measures V, A, Hz <strong>and</strong> unbalances perphase}}Measurement in true root mean square(TRMS)}}Optional expansion of its functions withexpansion modules:• y4 fully programmable relays• yProgrammable output rangeApplication}}Ideal for unbalanced 3 or 4 wire threephasenetworks for the analysis of electricalparameters.}}Time control with the timer function,(type CH)}}Control of the maximum dem<strong>and</strong>, thanksto the maximeters available per phase(type MD)FeaturesPower supply circuitPower supply 230 Vac (-10 ... +15 %)Frequency35 ... 450 HzConsumption5 V·AMeasurement circuitScope400 V F-N, 565 V P-P ... / 5 AAccuracy0.5 % (± 2 dig)Overload (permanent)1.2 I nConsumption0.6 V·AFrequency35 ... 450 HzDisplayDisplayThree 4-digit linesColourRed, high efficiencyDisplay refresh rate1 sAmbient conditionsStorage temperature - 40 ... +70 ºCOperating temperature - 10 ... +65 ºCBuild featuresBox materialSelf-extinguishing ABSDegree of protectionIP 54 front panelSize96 x 96 x 87 mmWeight350 gSt<strong>and</strong>ardsIEC 1010, IEC 348, IEC 664, EN 50081-1, EN 50082-1M2-21


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>CMM 96<strong>Digital</strong> three-phase measurementstation for panel mountingReferencesMeasurement Parameters Input Type CodeAC V,A, Hz <strong>and</strong> MD per phase 400 V p-n/ 565 V p-pCMM96-MD M20511AC V, A, Hz per phase <strong>and</strong> timer 400 V p-n/ 565 V p-pCMM96-CH M20512Expansible modulesInputs Outputs Type Code- 4 relays Module with 4 relays CMM 96 -MD M205221 CH input 4 relays Module with 4 relays CMM 96-CH M20524Coding tableM 2 X X X X 0 0 X XCodeAuxiliarypower supplyInsulatedinputsInternalCodeSt<strong>and</strong>ard (230 V) 0400 V ac 318 ... 36 V dc 7St<strong>and</strong>ard (not insulated) 0Insulated - ITF 1DimensionsConnectionsM2-22


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>ConvertersNarrowprofile <strong>transducers</strong>Electrical parameter transducerin a process signalDescription}}Convert voltage, current or frequency in asingle-phase system}}Very competitive quality / price ratio}}Ideal for small installations}}Very reliable <strong>and</strong> robust devices}}Valid for work under dem<strong>and</strong>ing conditionsApplication}}Systems for the conversion of the electricalparameters of single-phase networks inindustrial environments where there are dem<strong>and</strong>ingconditions <strong>and</strong> there is a reducedspace.}}Converts voltage, current or frequencyinto a single-phase system in analogue outputor process signal.}}Conversion of electrical parameter signalto process signal for PLCs.FeaturesCVE-A CCE CFEPower supply circuit 230 V ac (-15 ... +20 %) (*1)Frequency40 ... 90 HzConsumption2.5 V·AMeasurement circuitConsumption< 0.2 V·AFrequency45 ... 65 HzNominal voltage (U n) 0..0.690 V ac - 10..0.600 V acNominal current (I n) - 5 A ac -Measurement range 5-120 % (*2)Overload (permanent) - 300 % I n-Overvoltage 1000 V - 1000 VAnalogue output circuitVoltage load impedance > 500Current load impedance < 500Response time< 300 msRippling, in TRMS < 0,5 %InsulationTest voltage3 kVImpulse test4 kVAmbient conditionsStorage temperature -40 ... +70 ºCOperating temperature -10 ... +55 ºCAltitude2000 mBuild featuresBox materialABS V0Degree of protection Box: IP 20 / Front panel: IP 54Weight (g) 190 250 190St<strong>and</strong>ards IEC 529, IEC 688, IEC 801, EN 50081-1, EN 50082-1(*1) For other types of power supply, see the coding table(*2) CVE-A-AP i CFE-AP: Measurement range 70-110 %M2-23


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>Narrow profile<strong>transducers</strong>Converter of electrical parameters intoprocess signalsReferencesSt<strong>and</strong>ard auxiliary power supply: 230 Vac, 45...65 Hz (*)For non-st<strong>and</strong>ard purchase orders, please state the following: 1.Code, 2.Input range, 3.Outputrange, 4.Auxiliary power supply, 5. In CFE-AP, state the network voltage. (See coding table)Application Measurement Accuracy Input (*) Output (*) Type CodeVoltmeter300 V 4...20mA CVE-A M25011Voltmeter (*1) 230 V 0...20mA CVE-A-AP M25021Ammeter4...20mA CCE-A M251115 AAC0.5 % FEAmmeter (*1) 0...20mA CCE-A-AP M25121Frequency-meterFrequency-meter(Self-powered)45..0.55 Hz4...20mA CFE M255110...20mA CFE-AP M25521(*1) Self-powered: does not need an auxiliary power supply.(*) Other inputs, outputs <strong>and</strong> auxiliary power supplies are offered as an option (See coding table).Coding tableDimensionsM 2 X X X X 0 0 X X X X X1CodeInternalCodeSt<strong>and</strong>ard (300 V) 05 4 3 - OUTPUTS2 - INPUTSCVE-AVoltageCVE-A-APVoltageCurrentFrequencyCVE-A,CCE-A,CFECVE-A-AP,CCE-A-AP,CFE-APAuxiliarypowersupplyNetworkvoltage(CFE-AP)110 V 1400 V 2500 V 3690 V 4St<strong>and</strong>ard (230 V) 0110 V 1400 V 2St<strong>and</strong>ard (5 A) 01 A 110 A 4St<strong>and</strong>ard (45...55 Hz) 055...65 Hz 147..0.53 Hz 245...65 Hz 30..0.100 Hz 4380..0.420 Hz 5360..0.440 Hz 6340..0.460 Hz 7St<strong>and</strong>ard (4...20 mA) 00...20 mA 10..0.10 V 22..0.10 V 3St<strong>and</strong>ard (0...20 mA) 00..0.10 V 1St<strong>and</strong>ard (220...240 V) 0380...40 Vac 40/60 Hz 318...36 Vdc 7St<strong>and</strong>ard (230 V) 0 0110 V 0 1400 V 0 2ConnectionsCVE / CEECFECCEM2-24


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>High-precisionHigh-precision<strong>transducers</strong>Converter of electrical parametersinto process signalsDescription}}Wide range of models to measure themain parameters of the electrical network.}}Very reliable <strong>and</strong> robust devices}}Valid for work under dem<strong>and</strong>ing conditionsApplications}}Systems for the conversion of the electricalparameters of single <strong>and</strong> three-phasenetworks in industrial environments wherethere are dem<strong>and</strong>ing conditions}}Conversion of electrical parameters toprocess signal for PLC or displays.FeaturesCV-ACW /CYCCOS/ CPF /CFDPower supply circuit 220...240 V ac(*1)FrequencyConsumptionMeasurement circuitConsumptionFrequencyNominal voltage (U n) 0..0.690 V ac-Nominal current (I n) 5 A ac 0..0.3 A acCC-WG CC-D CC-G CF CR2 CT-PT CC-A CV-D500 mA...10 A40 ... 90 Hz2.5 V·A< 0.2 V·A45 ... 65 HzMeasurement range 0...150 % U n0...150 % 0...120 %0...20mA40 ...600 V ac-Overload (permanent) 300 % 150 % 300 % - 300 % 150 %Input impedance 3000 W / V -Analogue output circuitVoltage load impedance> 500 WCurrent load impedance< 500 WResponse time < 300 ms < 500 ms < 300 ms < 100 ms < 500 ms < 300 msRippling (TRMS) < 0,5 %InsulationTest voltage 3 kV 2 kV 3 kV 2 kVImpulse test (1, 2...50 ms) 4 kV 3 kV 4 kV 3 kVAmbient conditionsStorage temperature - 40 ... +70 ºCOperating temperature -10 ... +55 ºCAltitude2000 m0...20kHz180 W/ V0...200k-0..0.5A ac-0 mV...500 V dc-1000W / VM2-25


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>ConvertersHigh - precision<strong>transducers</strong>Converter of electrical parametersinto process signalsCV-ACW /CYCCOS/ CPF /CFDCC-WG CC-D CC-G CF CR2 CT-PT CC-A CV-DBuild featuresBox materialABS VOWeight (g) 310 540 310Ambient conditions IEC 529, IEC 688, IEC 801, EN 50081-1, EN 50082-1(*1) For other types of power supply, see the coding tableReferencesCV-A. AC voltage transducerSt<strong>and</strong>ard auxiliary power supply: 230 Vac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)Type of input Measurement Accuracy Input <strong>Digital</strong> Type of measurement Type CodeAlternatingvoltageAC± 0.5 % reading0...20 mACV-A-AP (*1)M25041± 0.2 % reading 690 V ac4...20 mA CV-A M25032± 0.2 % reading 0...20 mAMeasurement inmean valuesCV-A M25031± 0.2 % reading 0...20 mAMeasurement in trueCV-A-RMSM25051± 0.2 % reading 4...20 mAroot mean squareCV-A-RMS M25052(*1) Self-powered: does not need an auxiliary power supplyCC-A. Alternating current transducerSt<strong>and</strong>ard auxiliary power supply: 230 V ac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)Type of input Measurement Accuracy Input <strong>Digital</strong> Type Code± 0.2 % reading0...20 mA CC-A M25131AlternatingcurrentAC± 0.2 % reading 4...20 mA CC-A M25132± 0.2 % reading 5 A 0...20 mA CC-A-AP (1) M25141± 0.2 % reading 0...20 mA CC-A-RMS M25151± 0.2 % reading 4...20 mA CC-A-RMS M25152(*1) Self-powered: does not need an auxiliary power supplyCV-D. DC Voltage transducerSt<strong>and</strong>ard auxiliary power supply: 230 V ac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)Type of input Measurement Accuracy Input <strong>Digital</strong> Type CodeDC VoltageDC± 0.2 % reading0...20 mA CV-D M2506110 mV ... 500 V± 0.2 % reading 4...20 mA CV-D M25062M2-26


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>ConvertersHigh - precision<strong>transducers</strong>Transducer of electrical parametersinto process signalsReferencesCC-D. Direct current transducerSt<strong>and</strong>ard auxiliary power supply: 230 V ac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)Type of input Measurement Accuracy Input <strong>Digital</strong> Type CodeDC VoltageDC± 0.2 % reading500 µA0...20 mA CC-D M25161± 0.2 % reading... 10 A4...20 mA CC-D M25162CC-WG. Leakage current transducerSt<strong>and</strong>ard auxiliary power supply: 230 V ac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)Type of input Measurement Accuracy Input <strong>Digital</strong> Type CodeLeakage current AC ± 0.2 % reading 0..0.3 Aac 4...20 mA CC-WG M25631C-F. Frequency transducerSt<strong>and</strong>ard auxiliary power supply: 230 V ac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)Type of input Measurement Accuracy Input <strong>Digital</strong> Type CodeFrequencyAC± 0.2 % reading40..0.690 V0...20 mA CF M25531± 0.2 % reading0...20 kHz4...20 mA CF M25532CC-G. Galvanic insulation transducerSt<strong>and</strong>ard auxiliary power supply: 230 V ac, 40...90 HzType of input Measurement Accuracy Input <strong>Digital</strong> Type CodeInsulationgalvanic- ± 0.2 % reading 0...20 mA 0...20 mA CC-G M25610CT-PT100. Temperature transducerSt<strong>and</strong>ard auxiliary power supply: 230 V ac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)Type of input Measurement Accuracy Input <strong>Digital</strong> Type CodeTemperature -± 0.2 % readingDepending on0...20 mA CT-PT100 M25651± 0.2 % readingthe sensor4...20 mA CT-PT100 M25652M2-27


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>ConvertersHigh - precision<strong>transducers</strong>Transducer of electrical parametersinto process signalsReferencesCR-2. Resistance transducerSt<strong>and</strong>ard auxiliary power supply: 230 Vac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)Type of input Measurement Accuracy Input <strong>Digital</strong> Type CodeResistance -± 0.2 % reading0...20 mA CR-2 M256411...200 kΩ± 0.2 % reading 4...20 mA CR-2 M25642CW. Active power transducerSt<strong>and</strong>ard auxiliary power supply: 230 Vac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply, 5. (phase-phase), 6. I n, 7. f n(see coding table)Type ofinputMeasurement Accuracy System Input <strong>Digital</strong> Type CodeSingle-phase0...20 mA CW-M M252114...20 mA CW-M M25212ActivepowerAC± 0.5 % readingBalancedthree-phaseUnbalancedthree-phaseARON (3 wires)300 V.../5 A0...20 mA CW-TE M252214...20 mA CW-TE M252220...20 mA CW-TA M252314...20 mA CW-TA M25232Unbalancedthree-phaseARON (4 wires)0...20 mA CW-TAN M252414...20 mA CW-TAN M25242CY. Reactive energy transducerSt<strong>and</strong>ard auxiliary power supply: 230 Vac, 40...90 HzFor non-st<strong>and</strong>ard purchase orders, please state the following:1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply, 5. (phase-phase), 6. I n, 7. f n(see coding table)Type ofinputMeasurement Accuracy System Input <strong>Digital</strong> Type CodeSingle-phase0...20 mA CY-M M252514...20 mA CY-M M25252PowerfactorAC± 0.5 % readingBalancedthree-phaseUnbalancedthree-phaseARON (3 wires)300 V.../5 A0...20 mA CY-TE M252614...20 mA CY-TE M252620...20 mA CY-TA M252714...20 mA CY-TA M25272Unbalancedthree-phaseARON (4 wires)0...20 mA CY-TAN M252814...20 mA CY-TAN M25282M2-28


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>ConvertersHigh-precision<strong>transducers</strong>Transducer of electrical parametersinto process signalsDimensionsCV-A, CV-D, CC-A, CC-D, CR2ConnectionsCV-A CV-D CC-ACC-DCR2M2-30


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>ConvertersHigh-precision<strong>transducers</strong>Transducer of electrical parametersinto process signalsDimensionsCW, CY, CPFConnectionsCWCW-TA CW-TAN CW-TECYCY-TE CY-TA CY-TANCPFCPF-TE CPF-TEN CPF-MM2-31


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>ConvertersHigh-precision<strong>transducers</strong>Transducer of electrical parametersinto process signalsDimensionsCCOS / CFDConnectionsCCOSCFD-THD / CFD-DDimensionsConnectionsCT-PT100CT-PT100M2-32


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>ConvertersHigh-precision<strong>transducers</strong>Transducer of electrical parametersinto process signalsCoding tableM 2 X X X X 0 0 X X XCodeInternalCodeINPUTSOUTPUTSAlternatingvoltageAlternatingcurrentDC VoltageDirectcurrentPower,power factor,cos j(V, A)Distortion ISt<strong>and</strong>ard (300 V) 0110 V 1400 V 2500 V 3690 V 4St<strong>and</strong>ard (5 A) 01 A 110 A 4St<strong>and</strong>ard (10 V) 060 mV 11 V 2100 V 3500 V 4St<strong>and</strong>ard (20 mA) 0200 mA 11 A 210 A 3St<strong>and</strong>ard (300 V, .../ 5 A) 0110 V, .../5 A 1400 V, .../5 A 2500 V, .../5 A 3600 V, .../5 A 4300 V, .../1 A 5110 V, .../1 A 6400 V, .../1 A 7500 V, .../1 A 8600 V, .../1 A 9St<strong>and</strong>ard (5 A) 01 A 1Leakage current, Universal process 0ResistanceTemperatureFrequencyOutputs 1, 3Outputs 2AuxiliarypowersupplySt<strong>and</strong>ard ( 20 Ω) 0200 Ω 12 kΩ 220 kΩ 3St<strong>and</strong>ard (-200...+200 ºC) 0-200 ... +800 ºC 1St<strong>and</strong>ard (45...55 Hz) 055...65 Hz 147..0.53 Hz 257...63 Hz 30..0.100 Hz 4St<strong>and</strong>ard (0...20 mA) 00..0.1 mA 10..0.10 mA 22 V 35 V 40..0.10 V 5-20...0...20 mA 6-10...0...10 V 7-5...0..0.5 V 8St<strong>and</strong>ard (4...20 mA) 02..0.10 V 2St<strong>and</strong>ard (220...240 V) 0380...40 Vac 40/60 Hz 318...36 Vdc 790..0.140 Vdc 9M2-33


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>accessoriesAccessoryPowerStudioDescriptionSoftware.See M.9 CatalogueCode M90211AccessoryPowerStudio ScadaDescriptionSoftware.HASP USB LicenseSee catalogue M.9Code M90231AccessoryFront Panel AdaptorsDescriptionIP 65. Front panel protector 48 x 96 mmCode M29921Description}}Front panel adaptor 48 x 48 to 72 x 72 mmCode M29911}}Front panel adaptor 48 x 48 to 96 x 96 mmCode M29912}}Front panel adaptor 72 x 72 to 96 x 96 mmCode M29914Description}}Front panel adaptor 48 x 96 to 96 x 96 mmCode M29913M2-34


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>M2-35


<strong>Digital</strong> <strong>instruments</strong> <strong>and</strong> <strong>measuring</strong> <strong>transducers</strong>+ information: central@circutor.eswww.circutor.comDesigned by: Comunication dpt. - CIRCUTOR, SACIRCUTOR, SA - Vial Sant Jordi, s/n08232 Viladecavalls (Barcelona) SpainTel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14central@circutor.esCIRCUTOR, SA reserves the right to change the content of this catalogue without prior warning

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!