Catalyst 3560-E Switch Getting Started Guide - Cisco
Catalyst 3560-E Switch Getting Started Guide - Cisco Catalyst 3560-E Switch Getting Started Guide - Cisco
• Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescentlighting fixtures. Make sure the cabling is safely away from other devices that might damage thecables.• Airflow around the switch and through the vents is unrestricted.• Temperature around the unit does not exceed 113°F (45°C). If the switch is installed in a closedor multirack assembly, the temperature around it might be greater than normal room temperature.• For copper connections on Ethernet ports, cable lengths from the switch to connected devices canbe up to 328 feet (100 meters).• For cable lengths for X2 transceiver modules and SFP-module connections, see the hardwareinstallation guide on Cisco.com and the documentation that shipped with the module.Installation Warning StatementsThis section includes the basic installation warning statements. Translations of these warningstatements appear in the Regulatory Compliance and Safety Information for the Catalyst 3750-E andCatalyst 3560-E Switch guide.WarningTo prevent the switch from overheating, do not operate it in an area that exceeds themaximum recommended ambient temperature of 113°F (45°C). To prevent airflowrestriction, allow at least 3 inches (7.6 cm) of clearance around the ventilation openings.Statement 17BWarningDo not reach into a vacant slot or chassis while you install or remove a module or a fan.Exposed circuitry could constitute an energy hazard. Statement 20612
WarningTo prevent bodily injury when mounting or servicing this unit in a rack, you must takespecial precautions to ensure that the system remains stable. The following guidelinesare provided to ensure your safety:• This unit should be mounted at the bottom of the rack if it is the only unit in the rack.• When mounting this unit in a partially filled rack, load the rack from the bottom to the top withthe heaviest component at the bottom of the rack.• If the rack is provided with stabilizing devices, install the stabilizers before mounting orservicing the unit in the rack. Statement 1006WarningThis unit is intended for installation in restricted access areas. A restricted access areacan be accessed only through the use of a special tool, lock and key, or other means ofsecurity. Statement 1017WarningOnly trained and qualified personnel should be allowed to install, replace, or service thisequipment. Statement 1030CautionTo comply with the Telcordia GR-1089 Network Equipment Building Systems (NEBS)standard for electromagnetic compatibility and safety, connect the Ethernet cables only tointrabuilding or nonexposed wiring or cabling.NoteThe grounding architecture of this product is DC-isolated (DC-I)13
- Page 1 and 2: GETTING STARTED GUIDECatalyst 3560-
- Page 3 and 4: SYSTRPSMASTRSTATDUPLXSP EDSTACKPoEM
- Page 7 and 8: Step 15Step 16(Optional) You can en
- Page 9 and 10: Refreshing the PC IP AddressAfter y
- Page 11: Other Management OptionsYou can use
- Page 15 and 16: 10-5 A50-60 HZAC OK PS OKAttaching
- Page 17 and 18: 6 Connecting to the Switch PortsThi
- Page 19 and 20: Install SFP Modules and Connect to
- Page 21 and 22: Resetting the SwitchThis section de
- Page 23 and 24: 9 Cisco Warranty TermsCatalyst 3560
• Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescentlighting fixtures. Make sure the cabling is safely away from other devices that might damage thecables.• Airflow around the switch and through the vents is unrestricted.• Temperature around the unit does not exceed 113°F (45°C). If the switch is installed in a closedor multirack assembly, the temperature around it might be greater than normal room temperature.• For copper connections on Ethernet ports, cable lengths from the switch to connected devices canbe up to 328 feet (100 meters).• For cable lengths for X2 transceiver modules and SFP-module connections, see the hardwareinstallation guide on <strong>Cisco</strong>.com and the documentation that shipped with the module.Installation Warning StatementsThis section includes the basic installation warning statements. Translations of these warningstatements appear in the Regulatory Compliance and Safety Information for the <strong>Catalyst</strong> 3750-E and<strong>Catalyst</strong> <strong>3560</strong>-E <strong>Switch</strong> guide.WarningTo prevent the switch from overheating, do not operate it in an area that exceeds themaximum recommended ambient temperature of 113°F (45°C). To prevent airflowrestriction, allow at least 3 inches (7.6 cm) of clearance around the ventilation openings.Statement 17BWarningDo not reach into a vacant slot or chassis while you install or remove a module or a fan.Exposed circuitry could constitute an energy hazard. Statement 20612