<strong>RTI</strong> <strong>Technologies</strong>, Inc.HOSE EVACUATIONIt's important that Air not be introduced into the A/C System during a Charging procedure. If a DeepVacuum procedure was performed previously, the following Hose Evacuation Procedure is notrequired. If the service valves on the hoses have been open, the following procedure must beperformed:Figure 4 Hose EvacuationTo Evacuate Hoses, refer to Figure 4 and follow these steps:1. Close Red and Blue Hose Valves.2. Open High and Low Gauge Valves.3. Press top (ON) of rocker switch marked RECOVER/RECYCLE.4. Let the <strong>TC670E</strong> run until a vacuum is seen on the Low Side Gauge.5. Turn High and Low Gauge Valves to OFF.6. Press bottom (OFF) of rocker switch marked RECOVER/RECYCLE. All Air has now beenremoved from the Hoses.7. Vent any Non-condensable Gas as described in the previous section.September 19, 1997 Page 11