A6 – Port ConfigurationResetting a PortResetting a PortEnter the Reset Port command to reinitialize one or more ports and to discard anytemporary changes that have been made to the administrative state or link speed.The following example reinitializes port 15:<strong>QLogic</strong>8<strong>Gb</strong>T #> reset port 15Configuring Port Threshold AlarmsThe I/O module can monitor a set of port errors and generates alarms based onuser-defined sample windows and thresholds. These port errors include thefollowing:• Cyclic Redundancy Check (CRC) errors• Decode errors• ISL connection count• Device login errors• Device logout errors• Loss-of-signal errorsYou make changes to the port threshold alarms by modifying the I/O moduleconfiguration as described in “Modify an I/O <strong>Module</strong> Configuration” on page 5-10.Refer to Table 12-15 <strong>for</strong> a description of the port alarm threshold parameters.The I/O module will down a port if an alarm condition is not cleared within threeconsecutive sampling windows (by default 30 seconds). Reset the port to bring itback online. An alarm is cleared when the threshold monitoring detects that theerror rate has fallen below the falling trigger.59245-01 A 6-13