12 – Command ReferenceSet Config ThresholdSNotesExamplesThe I/O module will down a port if an alarm condition is not cleared within threeconsecutive sampling windows (by default 30 seconds). Reset the port to bring itback online. An alarm is cleared when the threshold monitoring detects that theerror rate has fallen below the falling trigger.The following is an example of the Set Config Threshold command:<strong>QLogic</strong>8<strong>Gb</strong>T #> admin start<strong>QLogic</strong>8<strong>Gb</strong>T (admin) #> config edit<strong>QLogic</strong>8<strong>Gb</strong>T (admin-config) #> set config thresholdA list of attributes with <strong>for</strong>matting and current values will follow.Enter a new value or simply press the ENTER key to accept the current value.If you wish to terminate this process be<strong>for</strong>e reaching the end of the listpress 'q' or 'Q' and the ENTER key to do so.ThresholdMonitoringEnabled (True / False) [False ]CRCErrorsMonitoringEnabled (True / False) [True ]RisingTrigger (decimal value, 1-1000) [25 ]FallingTrigger (decimal value, 0-1000) [1 ]SampleWindow (decimal value, 1-1000 sec) [10 ]DecodeErrorsMonitoringEnabled (True / False) [True ]RisingTrigger (decimal value, 1-1000) [25 ]FallingTrigger (decimal value, 0-1000) [0 ]SampleWindow (decimal value, 1-1000 sec) [10 ]ISLMonitoringEnabled (True / False) [True ]RisingTrigger (decimal value, 1-1000) [2 ]FallingTrigger (decimal value, 0-1000) [0 ]SampleWindow (decimal value, 1-1000 sec) [10 ]LoginMonitoringEnabled (True / False) [True ]RisingTrigger (decimal value, 1-1000) [5 ]FallingTrigger (decimal value, 0-1000) [1 ]SampleWindow (decimal value, 1-1000 sec) [10 ]LogoutMonitoringEnabled (True / False) [True ]RisingTrigger (decimal value, 1-1000) [5 ]FallingTrigger (decimal value, 0-1000) [1 ]SampleWindow (decimal value, 1-1000 sec) [10 ]LOSMonitoringEnabled (True / False) [True ]RisingTrigger (decimal value, 1-1000) [100 ]FallingTrigger (decimal value, 0-1000) [5 ]SampleWindow (decimal value, 1-1000 sec) [10 ]Finished configuring attributes.This configuration must be saved (see config save command) and activated (seeconfig activate command) be<strong>for</strong>e it can take effect.To discard this configuration use the config cancel command.12-72 59245-01 A

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!